64
Overspeeding parameters (ID=x911)
Parameter
ID
Parameter value
Value
type
MIN
MAX
Default
Recommended
Overspeeding mode
x911
0
5
0
-
U8
0
Disable
1
No DOUT
control
2
DOUT 1
control
3
DOUT 2
control
4
DOUT 3
control
5
DOUT 4
control
Max Allowed Speed
0
300
90
-
U16
Configuring format:
<Overspeeding mode>,<MaxSpeed>
Immobilizer (ID=x912)
Immobilizer mode
x912
0
5
0
-
U8
0
Disable
1
No DOUT
2
DOUT1
control
3
DOUT2
control
4
DOUT3
control
5
DOUT4
control
iButton List checking
0 (Disable)
1 (Enable)
0
-
U8
Ignition Timeout
1
255
30
-
U16
Configuring format:
<ImmobMode> <button_enable><TMO>
Excessive Idling (ID=x913)
Excessive Idling
x913
0 (Disable)
1 (Enable)
0
-
U8
Time to stationary
0
255
1
-
U16
Time to movement
0
255
1
-
U16
Configuring format:
<Enable>,<Time to stationary>,<Time to movement>
Содержание FM6320
Страница 1: ...FM6320 User Manual V1 13...