121
Figure 64 Adding contact on tachograph connector
Tachograph D8 and adapter K-Line connectors connected directly.
Tachograph mounted on vehicles does not have D8 contact. In order to add it, you
have to undo the hooks and add the contacts (Figure 64). Contact code in Farnell
system: 925596-1.
Direct GND connection is required only if vehicle and tachograph grounds are not
merged. (It can be checked using multimeter. Connection between different
grounds should be 0 volts)
NOTE! Connecting to Stoneridge tachograph, for K-Line data, this configuration must take place:
1.
Insert Company card in tachograph.
2.
Configure tachograph in this way:
Menu->Settings->Parameters->D8 data format->SRE
Each described Vehicle Data element is packed to standard AVL packet and sent to
server. Parameter values are sent depending on configuration element ID that are described in
„K LINE ID“ column (IO parameter ID).
Vehicle data configuration window (Figure 65) can be opened by selecting “K Line” in the
Configurator. There is the list which holds all elements, each one can be selected by ticking to its
name.
Содержание FM6320