LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 261 of 273
#EVMONI – Set the single Event Monitoring
<param>
It can be a numeric or string value depending on the value of
<paramType>
and on the type of event.
If
<paramType>
is 0, then
<param>
is a string containing the AT
command:
• It has to be enclosed between double quotes
• It has to start with the 2 chars AT (or at)
• If the string contains the character ”, then it has to be replaced with the 3
characters \22
• the max string length is 96 characters
• if it is an empty string, then the AT command is erased
• If
<label>
is VBATT,
<paramType>
can assume values in the range
0 - 2.
o if
<paramType>
= 1,
<param>
indicates the battery voltage
threshold in the range 0 – 500, where one unit corresponds to 10 mV
(therefore 500 corresponds to 5 V). (Default: 0)
o if
<paramType>
= 2,
<param>
indicates the time interval in
seconds after that the voltage battery under the value specified with
<paramType>
= 1 causes the event. The range is 0 – 255.
(Default: 0)
• If
<label>
is DTR,
<paramType>
can assume values in the range 0 - 2.
o if
<paramType>
= 1,
<param>
indicates the status high or low
under monitoring. The values are 0 (low) and 1 (high). (Default: 0)
o if
<paramType>
= 2,
<param>
indicates the time interval in
seconds after that the DTR in the status specified with
<paramType>
= 1 causes the event. The range is 0 – 255.
(Default: 0)
• If
<label>
is ROAM,
<paramType>
can assume only the value 0. The
event under monitoring is the roaming state.
• If
<label>
is CONTDEACT,
<paramType>
can assume only the value
0. The event under monitoring is the context deactivation.
• If
<label>
is STARTUP,
<paramType>
can assume only the value 0.
The event under monitoring is the module start-up.
• If
<label>
is REGISTERED,
<paramType>
can assume only the value
0. The event under monitoring is the network registration (to home
network or in roaming) after the start-up and the SMS ordening.
• If
<label>
is GPIOX,
<paramType>
can assume values in the range
0 - 3.
o if
<paramType>
= 1,
<param>
indicates the GPIO pin number;
supported range is from 1 to a value that depends on the hardware.
(Default: 1)
o if
<paramType>
= 2,
<param>
indicates the status high or low
under monitoring. The values are 0 (low) and 1 (high) . (Default: 0)
o if
<paramType>
= 3,
<param>
indicates the time interval in