LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 142 of 273
#CCID - Read ICCID
OK
#PCT - Display PIN Counter
AT#PCT
Execution command reports the PIN/PUK or PIN2/PUK2 input remaining attempts,
depending on
+CPIN
requested password in the format:
#PCT: <n>
where:
<n>
- remaining attempts
0 - the SIM is blocked.
1..3 - if the device is waiting either SIM PIN or SIM PIN2 to be given.
1..10 - if the device is waiting either SIM PUK or SIM PUK2 to be given.
AT#PCT=?
Test command returns the OK result code.
Example
AT+CPIN?
+CPIN: SIM PIN
OK
AT#PCT
Check PIN remained counter
#PCT: 3
OK
AT+CPIN=1111
Input incorrect PIN number
+CME ERROR: incorrect password
AT#PCT
#PCT: 2
#SHDN - Software Shutdown
AT#SHDN
Execution command causes device detach from the network and shut down.
Before definitive shut down an
OK
response is returned.
Note: after the issuing of this command any previous activity is terminated and the
device will not respond to any further command.
Note: to turn it on again Hardware pin ON/OFF must be tied
low
.
Note: The maximum time to shutdown the device, completely is 25 seconds.
AT#SHDN=?
Test command returns the OK result code.
#REBOOT - Reboot
AT#REBOOT
Execution command reboots the module.
AT#REBOOT=?
Test command returns the OK result code.
Содержание LE910-SKG