LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 164 of 273
#NITZ - Network Timezone
Network Name applying, (c)
#NITZ
URC (as well as its format) are currently
enabled or not, in the format:
#NITZ: <val>,<mode>
AT#NITZ=?
Test command returns supported values of parameters
<val>
and
<mode>
.
#CCLK – Clock Management
AT#CCLK=<time>
Set command sets the real-time clock of the ME.
Parameter:
<time> - current time as quoted string in the format:
"
yy/MM/dd,hh:mm:ss±zz,d
"
yy
- year (two last digits are mandatory), range is 00..99
MM
- month (two last digits are mandatory), range is 01..12
dd
- day (two last digits are mandatory)
The range for dd(day) depends either on the month and on the year it refers to.
Available ranges are:
(01..28)
(01..29)
(01..30)
(01..31)
Trying to enter an out of range value will raise an error
hh
- hour (two last digits are mandatory), range is 00..23
mm
- minute (two last digits are mandatory), range is 00..59
ss
- seconds (two last digits are mandatory), range is 00..59
±
zz
- time zone (indicates the difference, expressed in quarter of an hour,
between the local time and GMT; two last digits are mandatory), range is -
47..+48
d
– number of hours added to the local TZ because of Daylight Saving
Time(summertime) adjustment; range is 0-2
AT#CCLK?
Read command returns the current setting of the real-time clock, in the format
<time>.
Note: if the time is set by the network but the DST information is missing, or the
time is set by +CCLK command, then the <time> format is:
"yy/MM/dd,hh:mm:ss±zz"
AT#CCLK=?
Test command returns the
OK
result code.
Example
AT#CCLK="02/09/07,22:30:00+04,1"
OK
AT#CCLK?
#CCLK: 02/09/07,22:30:25+04,1
OK
Содержание LE910-SKG