LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 167 of 273
where:
<mode>
- SIM Detection mode, as before
<simin>
- SIMIN pin real status
0 - SIM not inserted
1 - SIM inserted
AT#SIMDET=?
Test command reports the supported range of values for parameter
<mode>
#CGPADDR - Show PDP Address
AT#CGPADDR=
[<cid>[,<cid>
[,…]]]
Execution command returns a list of PDP addresses for the specified context
identifiers in the format:
#CGPADDR: <cid>,<PDP_addr>[<CR><LF>#CGPADDR: <cid>,
<PDP_addr>[…]]
Parameters:
<cid>
- Context identifier
1..5 - A numeric parameter which specifies a particular PDP context definition
(see
+CGDCONT
command). If no
<cid>
is specified, the addresses for all
defined contexts are returned.
<PDP_addr>
- a string that identifies the terminal in the address space applicable
to the PDP. The address may be static or dynamic. For a static address, it will be
the one set by the
+CGDCONT
command when the context was defined. For a
dynamic address it will be the one assigned during the last PDP context activation
that used the context definition referred to by
<cid>
;
<PDP_addr>
is omitted if
none is available
AT#CGPADDR=?
Test command returns a list of defined
<cid>
s.
Example
AT#SGACT=1,1
+IP: xxx.yyy.zzz.www
OK
AT#CGPADDR=1
#CGPADDR: 1,”xxx.yyy.zzz.www”
OK
AT#CGPADDR=?
#CGPADDR: (1)
OK
Reference
3GPP TS 27.007
#I2CWR – Write to I2C
AT#I2CWR=
<sdaPin>, <sclPin>,
<deviceId>,
This command is used to Send Data to an I2C peripheral connected to module
GPIOs
Содержание LE910-SKG