#SERVINFO - Serving Cell Information
<dBM>
- received signal strength in dBm
<NetNameAsc>
- operator name, quoted string type
<NetCode>
- country code and operator code, hexadecimal representation
<PSC>
- Primary Synchronisation Code
<LAC>
- Localization Area Code
<DRX>
- Discontinuous reception cycle length
<SD>
- Service Domain
0 – No Service
1 – CS Only
2 – PS Only
3 – CS & PS
<RSCP>
- Received Signal Code Power in dBm
<NOM>
- Network Operation Mode
..”I”
“II”
..”III”
<RAC>
- Routing Area Color Code
Note 1: In HE seriese, value of <PB-ARFCN> is displayed as blank.
3.5.5.1.16.
Read Analog/Digital Converter Input - #ADC
#ADC - Read Analog/Digital Converter Input
AT#ADC=
<adc>,<mode>
[,<dir>]
Execution command reads pin
<adc>
voltage, converted by ADC, and outputs it in
the format:
#ADC: <value>
where:
<value>
- pin
<adc>
voltage, expressed in mV
Parameters:
<adc>
- index of pin
1 - available
2 - available
3 - available
<mode>
- required action
2 - query ADC value
<dir>
- direction; its interpretation is currently not implemented
0 - no effect.
Note: The command returns the last valid measure.
AT#ADC?
Read command reports all pins voltage, converted by ADC, in the format:
#ADC: <value>[<CR><LF>#ADC: <value>[…]]
AT#ADC=?
Test command reports the supported range of values of the command parameters
<adc>
,
<mode>
and
<dir>
.