+COPS - Operator Selection
Parameters:
<mode>
0 - Automatic, in this case other fields are ignored and registration is done
automatically by ME(default)
1 - Manual. Other parameters like format and operator need to be passed
2 - Deregister from network
3 - It sets <format> value. In this case <format> becomes a mandatory input
4 - Manual / Automatic. In this case if manual selection fails then automatic
mode is entered
<format>
0 - <oper> format presentations are set to long alphanumeric. If Network
name not available it displays combination of Mcc and MNC in string
format.
1 - <oper> format presentation is set to short alphanumeric.
2 - <oper> format presentations set to numeric.
<oper>
string type given in format <format>; this field may be up to 16 characters
long for long alphanumeric format and up to 8 characters for short alphanumeric
format. Numeric format is 5 or 6 Characters long because it depends on
MCC/MNC. MCC is only 3 digits. But MNC is 2 or 3 digits.
<AcT>
access technology selected:
0 GSM
2 UTRAN
AT+COPS?
Read command returns current value of
<mode>
,
<format>
and
<oper>
in format
<format>
; if no operator is selected,
<format>
and
<oper>
are omitted
+COPS: <mode>[,<format>,<oper>[,< AcT>]]
AT+COPS=?
Test command returns a list of quintuplets, each representing an operator present
in the network.
The quintuplets in the list are separated by commas:
+COPS:
: [list of supported (<stat>,long alphanumeric <oper>
,short alphanumeric <oper>,numeric <oper>,< AcT>)s]
[,,(list of supported <mode>s),(list of supported <format>s)]
where:
<stat>
- operator availability
0 - unknown
1 - available
2 - current
3 - forbidden
<AcT>
access technology selected:
0 GSM
1 GSM Compact
2 UTRAN