![Telit Wireless Solutions HE863 Series Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/telit-wireless-solutions/he863-series/he863-series_at-commands-reference-manual_1083663076.webp)
HE863 family AT commands reference guide
80377ST10083a Rev.6 – 2012-11-12
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved.
Page 76 of 229
+CPBR - Read Phonebook Entries
Where:
<index
> integer type values in the range of location numbers of phonebook
memory
<number>
string type phone number of format <type>
<type>
type of address octet in integer format
<text>
string type field of maximum length <tlength>
<hidden>
indicates if the entry is hidden or not ? only available, if a UICC with
an active
USIM application is present
0 phonebook entry not hidden
1 phonebook entry hidden
<group>
string type field of maximum length <glength>
<adnumber>
string type phone number of format <adtype>
<adtype>
type of address octet in integer format (refer TS 24.008[8] subclause
10.5.4.7)
<secondtext>
string type field of maximum length <slength>
<email>
string type field of maximum length <elength>
AT+CPBR=?
Test command returns the supported range of values for parameters
<indexn>
and
the maximum lengths of
<number>
and
<text>
fields, in the format:
+CPBR: (list of supported
<index>s),[nlength],[tlength],[<glength>],[<alength>],[<slength>],
[<elength>]
OK
where:
<index
> integer type values in the range of location numbers of phonebook
memory
<nlength>
integer type value indicating the maximum length of field
<number>
<tlength>
integer type value indicating the maximum length of field <text> (40).
<glength>
integer type value indicating the maximum length of field <group>
<alength>
integer type value indicating the maximum length of field <anr>
<slength>
integer type value indicating the maximum length of field <secondtext>
<elength>
integer type value indicating the maximum length of field <email>
Note
Remember to select the PB storage with
+CPBS
command before issuing PB
commands.
Example AT+CPBS=”SM”
OK
AT+CPBS?
+CPBS: "SM",1,100
OK
AT+CPBR=?
+CPBR: (1-100),40,255
OK
AT+CPBR=1