EN
465
8.2 Equipment Error Codes
Equipment Error
Code(hexadecimal)
Description
0x08030001
Unavailable resources for counter activation
0x08030006
Unavailable resources for the service in the OLT
0x08030100
Service has active probe or counter
0x08XXXXXX
0x69XXXXXX
Equipment firmware error (XX means any value)
0x07XXXXXX
Internal Equipment Error (IPC Error) (XX means any value)
0x0A03000E
Invalid Operational State
0x0A030113
The proposed serial number already exists.
0x0A030114
ONTs list is updating
0x0A030115
The serial number is invalid.
0x0A030117
The password is being used by another ONU
0x0A030118
Register type is invalid.
0x0D030100
The minimum distance is greater than the maximum
0x0D030101
The difference between minimum and maximum distance is greater than allowed
0x0D030102
There are ONTs connected to the PON port which do not allow it to be disabled
0x0D030103
FEC Downstream is not enabled on the PON port
0x0D030104
FEC Upstream is not enabled on the ONT
0x0D030105
The PON port has ONTs with services
0x0D030106
The PON port is used in unstacked services with different MAC Bridge type
0x0D030107
The PON port is in VLAN mapping mode
0x0D030108
The PON port is in VLAN + P-Bit mapping mode
0x0D034320
Invalid protection group administrative state
0x0D034321
Invalid protection group mode
0x0D034322
Invalid protection group reversibility
0x0D034323
Invalid protection group ‘wait to restore’ value
0x0D034324
Invalid protection group ‘hold-off timer’ value
0x0D034325
Invalid protection group primary port
0x0D034326
Invalid protection group protection port
0x0D034327
Protection group primary port is not active
0x0D034328
Protection group protection port is active
0x0D034330
The ports of the protection group cannot be the same
0x0D034331
The protection group is active
0x0D034332
The protection group is not active
0x0D034333
The protection group entity ID already exists
0x0D034334
Port in use by a protection group
0x0D034335
Protection port has ONUs
0x0D034336
Protection port has services
0x0D034337
The protection and working ports of the protection group belong to the same
card
0x0D034338
The protection is being activated/deactivated or sinchronyzing
0x0D034339
The protection information is not synchronized
0x0D034891
Service is in use on a Multicast Channel
0x0D03489A
There is at least one ACL associated to the service
0x0D0348A0
There is at least one probe associated to the service
0x1D030303
Incompatible hardware version
0x1D034880
Invalid ID
0x1D034881
Invalid Admin
0x1D034882
Invalid Type
0x1D034883
Invalid Client Port
0x1D034884
Not enough resources to active ONU counter. Max nbr reached
0x1D034886
The respective OLT service is not admin enabled
0x1D034890
Only inactive services can be removed
0x1D034891
UNI-C-Tag already in use by another service in this ONU
Содержание OLT 769401
Страница 1: ...GPON OLT 8xPON 8xGbE 2x10GbE EN Ref 769401 User Manual w w w t e l e v e s c o m ...
Страница 2: ......
Страница 9: ...EN 9 ...
Страница 11: ...EN 11 ...
Страница 139: ...EN 139 Figure 6 9 SFP Module detailed information Figure 6 10 GPON Interfaces Status ...
Страница 149: ...EN 149 Figure 6 20 DHCP counters ...
Страница 473: ...EN 473 ...
Страница 474: ......
Страница 475: ......
Страница 476: ......
Страница 477: ...EN 477 ...
Страница 478: ...Descripción del producto 478 ...
Страница 479: ...EN 479 ...
Страница 480: ...Descripción del producto 480 ...
Страница 481: ...EN 481 ...
Страница 482: ...Descripción del producto 482 ...