background image

EN

433

Figure 7-539: Output of ”availableValues” command in this node context

Parameter

Description

Service (ID) Name

Available Service identified by Service ID (number) and Service Name

Slot

Slot number where is the port with the service available

Port

Port number where the service is available.

Table 7-502: “availableValues” command output table parameters

7.6.19.8.1.2 “show” command

Name

show

Description

Show  the  statistics  for  a  given  service  and  interface,  whose  counter  has  already 

been activated.

Full path

/services/statistics/counters/show

Mandatory Parameters

--serviceID

Screen Output

Table, Figure 7-541. Table parameters description in Table 7-504.

Table 7-503: “show” command information

/cli/services/statistics/counters> show ?

Usage:

  SHOW            Show the statistics for a given service and interface, whose counter has 

already been activated.

   <MANDATORY>

   --serviceID                       Select an OLT service by ID.

   [OPTIONAL]

   --port                            Identifies an interface on the OLT. (e.g.: pon.2; eth.3; 

lag.1)

Figure 7-540: CLI on line help on “show” command usage in this node context

Содержание OLT 769401

Страница 1: ...GPON OLT 8xPON 8xGbE 2x10GbE EN Ref 769401 User Manual w w w t e l e v e s c o m ...

Страница 2: ......

Страница 3: ... Security 24 2 8 4 1 ACL Access Control Lists Support 24 2 8 4 2 White List for Multicast Group Addresses 24 2 8 4 3 IP Source Guard 24 2 8 4 4 MAC Duplication 24 2 8 4 5 MAC IP Spoofing 25 2 8 4 6 Storm Attack Rate Limiters 25 2 8 4 7 User Isolation 25 2 8 5 QoS 25 2 8 6 MTU 26 2 8 7 OAM 26 2 8 8 Ethernet Counters RFC2819 27 2 9 MAC 27 2 9 1 Dynamic Bandwidth Allocation DBA 27 2 9 2 MAC GPON DBA ...

Страница 4: ...al Dimensions 44 3 8 MTBF 44 3 9 Environmental ConditionsLicense Requirements 45 3 10 Electromagnetic Compatibility 45 3 11 System Parts 45 3 11 1 OLT Ref 769401 single board 46 3 11 1 1 Interfaces 46 3 11 1 2 LED Indicators 46 3 11 1 3 Interface Interconnection Cables 46 4 Setup 47 4 1 Configuring Dynamic Software UpgradeMechanical Packaging 47 4 2 ESD Precautions 47 4 3 OLT Ref 769401 System 47 ...

Страница 5: ... 119 5 2 4 18 ONU Software Update 120 5 2 4 19 Backup Management 123 5 2 4 20 USERS 128 6 Operation 129 6 1 Upgradingto a New OLT OS Software Release 129 6 1 1 Determining the Software Version 129 6 1 2 Upgrading to a New Software Release 129 6 1 3 OLT OS Installation Procedure 129 6 2 Status 130 6 2 1 System 132 6 2 2 Synchronism 133 6 2 2 1 Global 133 6 2 2 2 PTP 135 6 2 3 Interfaces 136 6 2 3 1...

Страница 6: ... rule ipv4 ext sub node 197 7 6 1 10 rule ipv4 std sub node 200 7 6 1 11 rule ipv6 ext sub node 202 7 6 1 12 rule mac sub node 205 7 6 2 applications node 207 7 6 2 1 firmware upgrade sub node 207 7 6 2 2 manager sub node 214 7 6 2 3 olt upgrade sub node 215 7 6 2 4 time sub node 216 7 6 3 backup manager node 108 7 6 3 1 create command 108 7 6 3 2 del serv conf command 222 7 6 3 3 export command 2...

Страница 7: ...12 7 6 12 1 config command 312 7 6 12 2 create command 313 7 6 12 3 remove command 313 7 6 12 4 show command 314 7 6 12 5 showconfig command 315 7 6 13 logs node 315 7 6 13 1 alarms sub node 315 7 6 14 mac table node 317 7 6 14 1 config command 317 7 6 14 2 show command 317 7 6 14 3 showconfig command 318 7 6 14 4 status sub node 319 7 6 15 multicast node 322 7 6 15 1 active groups sub node 322 7 ...

Страница 8: ...6 19 8 statistics sub node 432 7 6 20 synchronism node 440 7 6 20 1 global sub node 440 7 6 20 2 ptp sub node 447 7 6 20 3 status sub node 455 7 6 21 users node 458 7 6 21 1 config command 458 7 6 21 2 create command 459 7 6 21 3 remove command 459 7 6 21 4 show command 460 7 6 21 5 status command 461 7 6 22 utils node 461 7 6 22 1 ping command 461 7 6 22 2 tcpdump command 462 7 6 22 3 telnet comm...

Страница 9: ...EN 9 ...

Страница 10: ...also depicted The OLT is a high availability and high reliability high density scenario Optical Line Termination OLT equipment specially designed for fiber network infrastructures in Point to Multipoint P2MP FTTx Gigabit Passive Optical Network GPON architectures in urban deployment scenarios This equipment is intended to solve all your fiber access needs in terms of retail as well as wholesale cl...

Страница 11: ...EN 11 ...

Страница 12: ... OLT is a reliable high availability system that uses common element 1 1 protection Power Switch Fabric Processing and load balancing LACP at the Uplink interfaces To guarantee security the Advanced Encryption Standard AES is used in the system Multicast and IGMPv2 v3 snooping with proxy reporting are both enablers for a flexible IPTV service delivery Figure 2 1 OLT architecture Figure 2 1 shows t...

Страница 13: ...atform Mobile Backhaul services Applicable to WiMAX 2G 3G and 4G LTE networks Support transparent synchronization signals frequency phase and time transport according to NTP and PTP Protocols IEEE 1588 v2 and telecom profile Provide BITs interface for the connection of an external MHz or Mbps clock reference Video services IPTV RF Video Residential multiplay services Voice Voice over IP VoIP Inter...

Страница 14: ...ic is not processed The CPU is not part of the EVC Can be use 1 1 and N 1 topology 2 1 2 1 N 1 Services 2 1 2 1 1 1 Unicast Unstacked Services Forwarding is based on S VID DMAC e g Residential Gateway MAC Address Default GEM Port Transports Unicast Unknown Multicast and Broadcast MAC Addresses Multicast Services only have the Default GEM OLT ONT S VID101 MAC Table Subscriber GEMID11 DefaultGEM S V...

Страница 15: ...ID GEMID1 OLT ONT S VID101 MAC Table Subscriber GEMID4 GEMID3 S VID100 B S VID10 A GEMID4 S VID10 C GEMID5 GEMID6 S VID101 S VID12 GEMID7 S VID102 D GEMID8 S VID102 E GEMID9 S VID102 F GEMID5 GEMID6 C VID1 GEMID4 GEMID5 GEMID6 S VID102 MAC Table GEMID7 GEMID8 GEMID9 C VID2 GEMID7 GEMID8 GEMID9 S VID100 MAC Table GEMID1 GEMID2 GEMID3 GEMID1 GEMID2 GEMID3 GEMID2 S VID11 RG RG RG RG RG RG Figure 2 4 ...

Страница 16: ...2 S VID101 B GEMID13 S VID101 C GEMID11 GEMID12 S VID100 S VID101 C VID101 GEMID13 Figure 2 5 1 1 Unicast Stacked Services 2 1 2 3 Transparent LAN Services TLS 2 1 2 3 1 1 Bitstream Services The traffic is not processed The CPU is not part of the EVC Can be use 1 1 and N 1 topology OLT ONT S VID101 MAC Table Subscriber GEMID11 S VID100 A GEMID12 DefaultGEM S VID101 B GEMID13 DefaultGEM S VID101 C ...

Страница 17: ...atio is hardware ready L2 Manipulation Transparent Add change S Tag e C Tag Dynamic Bandwidth Allocation DBA In parallel with the data services the OLT System allows the transport of analog video services RF Overlay 2 3 Services The following services related features are supported by the OLT Up to 255 network services Up to 10 Client services per ONT Up to 447 Client services per PON in VLAN P bi...

Страница 18: ...commendation describes the transmission convergence layer for 10 Gigabit capable passive optical network systems 2 6 OMCI The OLT systems comply with ITU T G 988 10 2012 ONU management and control interface OMCI specification G 988 recommendation specifies the managed entities of a protocol independent management information base MIB that models the exchange of information between an optical line ...

Страница 19: ...s by SNMP 2 6 2 OMCI and ONU Software Upgrade The OLT supports ONUs automatic software upgrade via OMCI according to standard G 984 4 G 988 Following the control plane start software download order the downloading process is managed autonomously by the GPON MAC In order to inquire on the state of the operation queries are GPON MAC control plane enabled 2 7 FEC Upstream Downstream Configuration and...

Страница 20: ...N ID GPON ports Just membership up to 4k VLAN ID per port VLAN translation up to 8k VLAN ID 2 8 2 Multicast 2 8 2 1 Supported Features Support of IGMP v2 Support of IGMP v3 according to RFC3376 Multicast group features Support configuring the end point of the multicast static groups Support bandwidth configuration of each multicast group Display Client Service information in Multicast Active Group...

Страница 21: ...to perform the following actions The first Join for a certain Group received from the client side will be translated to a Join on the Network side using the OLT Source MAC and Source IP The last Leave for a certain group received from the client side will be translated to a Leave on the Network side using OLT Source MAC and Source IP The OLT transmits periodical IGMP General Queries to the client ...

Страница 22: ... GEM Port of the GPON interface where there are clients pretending to receive those Streams In order to check if the hosts are still watching the channels and they didn t disconnect without advising send a leave General Queries are periodical generated towards the hosts The Switch Fabric card acts like an IGMP Proxy receiving the requests from the line cards and checking if it is already receiving...

Страница 23: ...specific information as for example the service plan hired by the customer This field is composed by a string with 64 characters 2 8 3 2 Lightweith DHCPv6 Relay Agent Lightweight DHCPv6 Relay Agent is used to insert relay agent options in DHCPv6 message exchanges identifying client interfaces The messages received from the client interfaces of the following types will be discarded Advertise Reply ...

Страница 24: ... select the upstream multicast service VLAN when a particular client requests a group address The maximum number of groups is currently limited to 1024 but can go up to 4096 in the future 2 8 4 3 IP Source Guard IP Source Guard provides source IP address filtering on a Layer 2 port to prevent a malicious host from impersonating a legitimate host by assuming the legitimate host s IP address The fea...

Страница 25: ...can t communicate between themselves and just flow transparently through the Access Node 2 8 5 QoS The OLT system provides several QoS mechanisms that can be targeted to the flow characterized by one or two VLAN according with the type of service or can be targeted to the packets priority where each p bit is mapped in one of eight queues of each port The following QoS features are supported on eac...

Страница 26: ...T waits until the OLT assigns a transmission timeslot for that T CONT so that the most prioritized queues are the ones that transmit first In the OLT ingress the traffic is put into a queue according with what is defined in the p bit queue mapping Each of these queues has an associated scheduler and policer that control the traffic sent to the uplink Figure 2 11 Upstream QoS Diagram 2 8 6 MTU The ...

Страница 27: ... adequate T CONT to the service traffic in question There are five types of T CONT defined by the Fixed Assured and Maximum Parameters Type 1 Only fixed Bandwidth Type 2 Only Assured Bandwidth Type 3 Assured Maximum Bandwidth Type 4 Only Maximum Bandwidth Best Effort Type 5 Fixed Assured Maximum Bandwidth T CONT Type 1 Type 2 Type 3 Type 4 Type 5 Units Fixed BW RF RF1 0 0 0 RF5 b s Assured BW RA 0...

Страница 28: ...cupancy of bandwidth of each UN in recent broadcasts It is possible to configure the type of algorithm to use in allocating bandwidth for CBR non profiles as Status Reporting orTraffic Monitoring at the time of the creation of service corresponding traffic The change of the type of DBA services already provisioned is in principle possible except for the hardware limitation 2 9 3 Overbooking The OL...

Страница 29: ...e following protection mechanisms are supported by the OLT system GPON type B protection Uplink 1 1 protection LACP ERPS 2 11 1 1 Type B Redundancy for GPON Ports Configuration of type B redundancy for GPON ports according to G 984 is a functionality that enables the protection of a GPON port with another GPON port This feature is hardware enabled on the OLT system It allows1 1 GPON port protectio...

Страница 30: ... can be made according with Source MAC Destination MAC Source and Destination MAC 2 11 1 4 Ethernet Ring Protection Switching The OLT allows the implementation of ring protection according to ITU T G 8032 Y 1344 Ethernet Ring Protection Switching Support of open ring mode i e access ring is configured as G 8032 sub ring without R APS Virtual Channel Support of ETH CC ETH RDI Function CCM Connectiv...

Страница 31: ...s on the ring including nodes adjacent to RPL in this case nodes A and B Nodes receiving the RAPS message send a copy to the Ethernet Ring Protection ERP entity and also forward the received RAPS to the next node Node A Node B Node D Node C Failure Working Working CCM x RAPS RAPS Ring Protection Link Figure 2 15 Link failure Upon receiving the RPAS signal failure message Node A and B adjacent to R...

Страница 32: ... a logical communication channel in synchronous network connections Ethernet relies on a channel called Ethernet Synchronization Messaging Channel ESMC based on IEEE 802 3 Organization Specific Slow Protocol standards ESMC relays the SSM code that represents the quality level of the Ethernet Equipment Clock EEC in a physical layer To enable communications between various nodes the OLT equipment Sy...

Страница 33: ...y and handovers Timestamps between master and slave devices are sent within specific PTP packets and in its basic form the protocol is administration free The ITU T defined profile of the IEEE 1588 2008 specification has been specifically optimized to support telecommunications applications such as wireless Mobile Backhaul GPON and LTE The OLT Equipment supports IEEE 1588v2 as the following standa...

Страница 34: ...P at the OLT equipment Network clocking is supported on the following ports 1GbE 10GbE 2 12 5 1 Clock configurations supported by the OLT Different configurations are supported Clock Recovery System clock is recovered from the clocking source GbE 10Gbe and 100Gbe Clock Recovery from External Interface System clock is recovered from clocking source or a GPS interface Line to External The clock rece...

Страница 35: ...ync message has been sent the master clock device software reads the Sync message s departure time Tm1 through the time stamping unit inserts it into a Follow up message and sends that message out at Tm2 This message is received by slave clock device software atTs2 At this point the slave clock device software has the two times Ts1 Sync arrival time andTm1 Sync departure time The master to slave p...

Страница 36: ...n acts as the master to the downstream clock by generating a new 1588v2 message flow using timestamps generated from its internal reference The downstream flow to the ONT through the GPON LC TG16G unit Figure 2 Figure 2 19 Boundary Clock Synchronization mechanism Mobile Backhaul Example Measurements Limits The measurement limits for Frequency Accuracy MTIE TDEV are specified by the relevant ITU T ...

Страница 37: ...type TRAP ACK limited implementation Trap v2 and Inform are standard The UDP port can be configured to send traps default 162 standard 2 14 External Alarm Conditions Two external input alarm conditions are supported 2 15 Managers Configuration It is possible to configure the IPs of managers and set the reading and configuration permissions for each of them It is also possible to configure static I...

Страница 38: ...e Standards PON layer ITU T Recommendation G 984 x GPON ITU T Recommendation G 988 OMCI BBF 247 GPON certification program OLT interoperability BBF TR 156i3 Using GPON in the context of TR 101 Advanced Encryption Standard AES Forward Error Correction FEC Up to 128 ONT or ONUs per PON T CONTs 896 per PON GEM port IDs 4096 per PON Logical range 60 km Maximum differential distance 20 km ...

Страница 39: ...r IPv6 DHCPv6 Relay Agent Remote ID Option 37 ITU T Y 1731 IEEE 802 1ag Timing and synchronism ITU T Rec G 8261 Timing and synchronization aspects in packet Networks Synchronous Ethernet Sync E ITU T Rec G 8262 Timing characteristics of a synchronous Ethernet equipment slave clock IEEE1588v2 PTP ITU T Rec G 8263 Timing Characteristics of Packet based Equipment Clocks PEC ITU T Recommendation G 826...

Страница 40: ... 11 Safety UL 60950 1 CAN CSA 22 2 No 60950 1 EN 60950 1 IEC 60950 1 NOM 019 SCFI NEBS GR 63 CORE GR 1089 CORE Level 3 Type 2 ETSI EN 300 019 1 1 Storage Class 1 2 Not temperature controlled storage locations EN 300 019 1 2 Transportation Class 2 3 Public transportation EN 300 019 1 3 In Use Class 3 12 Partly temp controlled locations Table 2 4 Standards and Protocols ...

Страница 41: ... 40 km 10GBASE ZR ZW 80 km Laser type emitter SLM DFB SLM EA DFB SLM EA DFB Operation Range nm 1260 to 1355 1530 to 1565 1530 to 1565 Wave length typ nm 1310 1550 1550 Spectral width Max nm NA NA NA Min SMSR dB 30 30 30 Tolerated dispersion max ps nm NA NA 1600 Emission Power Max min dBm 0 5 8 2 4 0 4 7 4 0 1 0 Min Extinction Ratio dB 3 5 3 0 6 0 Receiver Type PIN PIN APD Attenuation Range dB NA N...

Страница 42: ...e interfaces characteristics 3 3 3 GPON Interfaces ITU T Recommendations G 984 2 G 984 2 Amd 1 G 984 2 Amd 2 GPON OLT Transceiver Items Unit B C OLT Tx OLT Tx Nominal bit rate Mbit s 2488 32 2488 32 Operating wavelength nm 1480 1500 1480 1500 Line code Scrambled NRZ Scrambled NRZ Minimum ORL dB 32 32 Mean launched power MIN dBm 1 5 3 Mean launched power MAX dBm 5 7 Extinction ratio dB 8 2 8 2 Tole...

Страница 43: ...ilters for the multiplex of video overlays and other enhancement band services and must include any Raman impairment from the overlay signal unit Single Fiber Minimum optical loss at 1490 nm dB 17 Minimum optical loss at 1310 nm dB 17 Maximum optical loss at 1490 nm dB 32 Maximum optical loss at 1310 nm dB 32 Maximum fiber length km 60 Table 3 7 C Link Budget 3 4 Power Supply Options As mentioned ...

Страница 44: ...nsions mm Dimension Height mm RU Width mm Depth mm Weight max Kg lb OLT Ref 769401 44 45 1 483 19 248 9 8 3 3 7 Table 3 9 Weight Physical Dimensions The OLT Ref 769401 chassis can be mounted on an ETSI ETS 300 119 2 type rack with a depth of 300mm 11 8 Figure 3 2 OLT Ref 769401 chassis front 3 8 MTBF Please see below the unit parts MTBF Mean Time Between Failure Type of Unit Unit name MTBF hours O...

Страница 45: ...ssipation and help moderate the thermal environment surrounding the electronic equipment The temperature conditions above are the expected extremes provided for equipment design purposes Normal operating temperature and humidity range experienced by the equipment in the closure is expected to be narrower The operating temperature minimum of 40 C represents a scenario where a cold start is required...

Страница 46: ... provides 2 LEDs named PRC ON that must indicate PRC stands for the word Processing and defines the overall state of the board IfLediseitherOFForsteadyGREENtheboardhasaninternalhardwaremalfuctionthatdoesnotallowtheboardtoboot If Led blinks GREEN 1 time per second the board is active If Led blinks GREEN 3 times per second the board is inactive ON reflects the state of the 48VDC power supplies A and...

Страница 47: ... source on the Disconnect Device before servicing the unit 4 2 ESD Precautions Important When performing OLT system service actions observe the following electrostatic discharge ESD precautions Wear an antistatic wrist strip at all times when handling any system part board or module Before handling any system part board or module discharge any static electricity by touching a grounded surface Remo...

Страница 48: ...unit is provided by two 48 VN egative power supply source connection source A and source B Important All unit power supply must be disconnected at the disconnect device before servicing the unit 4 4 3 Power Supply Connection Procedures Important When performing OLT system service actions observe electrostatic discharge ESD precautions ESD All unit power supply must be disconnected at the disconnec...

Страница 49: ...er Step 3 Remove the module dust cap to be able to access and turn the module handle to the horizontal position please see Figure 4 Step 4 Hold the module by the module handle Step 5 Position the module into the card module interface and push it into place Step 6 Release the module handle Step 7 Cover the module with the module dust cap or plug in the adequate parch cord optical connector 4 5 2 SF...

Страница 50: ...ce covers Figure It is mandatory to cover the unused optical card interfaces with the corresponding optical covers Figure 4 4 SFP SFP interface covers 4 6 1 1 FAN Module The OLT system has a single cooling module with three redundant FANs In case of failure of one of the FANs the air supplied by the adjacent units is enough for the proper functioning of the equipment Figure 4 5 OLT cooling module ...

Страница 51: ... the filter should be checked cleaned or replaced more often Should the filter require cleaning remove the filter from the server See Removing the Air Filter Take the filter to an open area and blow the particles from the filter using a can of compressed air Do not use a coarse brush or anything abrasive since they may damage the filter 4 6 1 3 FAN Module Replacement Procedures Important When perf...

Страница 52: ...as indicated in Figure 4 6 These cables consist of 6mm2 section and a length of 3m GND Green with Yellow stripes 48V DC Blue and 0V RTN DC Red Figure 4 6 4 7 2 ETH 10 100 1000 BASE T For the ETH 10 100 1000 BASE T interfaces are used RJ45 connectors as indicated in the figure below The expected range is 100m using UTP network cable category 5e or higher Figure 4 7 Ethernet Cable The ETH interface ...

Страница 53: ...h Fabric card alarm conditions and ACK Plug and PIN out 4 7 4 Optical The optical interfaces used in OLT system are Multi Source Agreement MSA type in GPON variants with SC PC connectors and in 10GbE SFP variants with LC PC connectors The optical cables are patch cords terminated with the optical connectors to match the optical interfaces BLUE Figure 4 9 SC PC connector ...

Страница 54: ...ceivers The SFP optical transceivers are the next generation SFP for 10Gbps transceivers singlemode and multimode fiber supporting multiple network protocols such as SONET SDH 10 Gigabit Ethernet 10GbE CWDM communications up to 80km Figure 4 11 Ethernet uplink SFP optical transceivers GPON network interfaces are in the form of SFP small form factor pluggable optical transceivers with SC PC optical...

Страница 55: ...aces 4 9 1 Electrical Fast Ethernet RJ 45 connectors are used for Ethernet 10 100 BASE T interfaces The expected range is 100 meters using category 6 cable as described in the IEEE 802 3 recommendations Figure 4 13 RJ45 connector ...

Страница 56: ...he Service Provider DCN or connected directly to the PC Ethernet port There are two management ports G1 and G2 in front panel of the Switch Fabric card G1 is the interface that should be used for the DCN connection since it has a configurable IP address G2 is the interface that should be used for local access to the Equipment since it has a fixed IP address The PC to be connected to G2 must be con...

Страница 57: ... provided Despite the compatibility with IE8 and IE9 compatibility view mode must be made with this browsers this option can be made near the place where the equipment s IP address is configured Generally in new browsers it may appear a button next to the URL called Compatibility View This button should be activated because it allows browser compatibility with Web Sites designed for older browsers...

Страница 58: ...ion and click in the button Sites In the Trusted Sites Window introduce the equipment IP address and select Add the Require server verification https for all sites must be unchecked Figure 5 4 Trusted Sites Configuration 5 2 WebTi 5 2 1 Access to the Equipment At the web browser window insert the equipment IP address to access The equipment WebTi interface main window will be displayed Figure 5 5 ...

Страница 59: ...t privileges for the operations that can be performed in the system Can also to change each system users password Admin Full access configuration of the equipment and of the accesses to the system users list and permissions Power OLT configuration permission cannot view or manage the system users list Guest Viewer permissions only status and logs information access Figure 5 6 Access Control ...

Страница 60: ...odes and subnodes The prompt indicates where in the navigation tree the user is currently positioned In each node subnode a set of command is available depending on the particular node subnode CLI general usage indications are provided in 7 3 CLI and subsections In the menu all the options to configure and check the equipment status are available By clicking on the menu expands or the menu collaps...

Страница 61: ...he OLT equipment That information is typically represented by graphic LEDs with different colors It is possible to check the WebTi version by passing the mouse over the equipment s name Figure 5 9 The meaning of the LED s is the following Off There is no board registered in the slot Green The board is operational Yellow The board is registered but absent from the system Red There is a conflict bet...

Страница 62: ...vents log registers Figure 5 10 OLT Main Page The fields changed in the table are marked with an exclamation mark in the corresponding line where the changes are made Figure 5 11 Tables Behavior There are three or more options in each configuration page Refresh Refreshes the current page Reset Puts the values to the original value of the page Save Saves the configuration of the selected parameters...

Страница 63: ...or message When an invalid operation execution order is issued by the user an error code and error description is displayed on the window bottom error message display bar Figure 5 12 For more information on the Invalid operation equipment error messages please refer to section 8 2 Equipment Error Codes Figure 5 12 Invalid Operation error message ...

Страница 64: ...quipment department person etc Location Custom field with the equipment location Firmware version Displays currently used firmware version Date on the equip Displays sets date on the equipment UTC Time on the equip Displays sets time on the equipment UTC Equipment IP address for management Displays currently configured IP address for local management Administrative status Equipment administrative ...

Страница 65: ...orted ONUs Up to 40 configured Profiles supported VoIP Up to 256 configured Profiles supported supported 30 Generic Profiles 30 Specific Profiles P bits to PQ Up to 720 configured Profiles supported Figure 5 14 OLT Profiles configuration sub menu CLI profiles node sub nodes and available commands including configuration are described in section 7 6 16 profiles node and subsections 5 2 4 2 1 DSCP D...

Страница 66: ...CIR bit s Committed Information Rate bandwidth that should be guaranteed on average CBS bytes Committed Burst Size maximum number of bytes in a burst of packets that should be guaranteed EIR bit s Excess Information Rate bandwidth in excess that can be supplied in case there is no traffic congestion EBS bytes Excess Burst Size maximum number of bytes in a burst of packets that can be supplied in c...

Страница 67: ... with a granularity of 8kbps and a maximum value of 1200000kbps Max BW Kbps Maximum bandwidth that results from the sum Fixed BW Assured BW bandwidth not assured with a granularity of 8kbps and a maximum value of 1200000kbps Bandwidth Eligibility Defines how the non assured bandwidth is handled NOTE Best EffortT CONTs are only attended if all Fixed and Non AssuredT CONTs have their requirements sa...

Страница 68: ...U profiles Parameter Description Admin Administrative state Name Profile name Vendor Vendor name Model Model name Ports Pon Number of GPON Ports Eth Number of Ethernet Ports RF Number of RF Ports VoIP Number of FXS ports Table 5 4 ONU profiles parameters table 5 2 4 2 5 VoIP VoIP profiles window is composed with two tables that are used to characterize different VoIP servers and FTP servers that s...

Страница 69: ...way used for the clients to reach the SIP server Table 5 5 VoIP Server profile configuration parameters table Parameter Description Admin Administrative state Name FTP server profile name FTP Server IP FTP server IP address Table 5 6 VoIP specific profile configuration parameters table 5 2 4 2 6 P bits to PQP PCP profiles window is used to P bit priority queues for the Upstream Sevices defined on ...

Страница 70: ...eue configuration dialog box Parameter Description Name PCP profile name Admin Administrative state Priority Queue Identification of profile priority queues by number Priority bit Identification of configured priority bits per queue Details The view link at this column will open a priority queue configuration dialog box showing the currently configured priority bits per queue for this PCP profile ...

Страница 71: ...urations Global configurations Parameter Description Management Interface eth management through local interface RJ45 connector inBand management through the uplink interfaces Table 5 8 Management interface configuration parameters table ...

Страница 72: ...d If the interface is used or not to manage the system Table 5 10 Uplink interface for InBand management configuration parameters table Finally a gateway may be configured on the system and it must belong to one of the networks configured previously through the IP Netmask Parameter Description Address Destination IP Network Mask Destination IP Mask Gateway Device Gateway to the configured network ...

Страница 73: ...er can set the equipment synchronization to take into account the SSM synchronization sources Synchronization Status Message Disabled the device ignores the SSM synchronization source Reversibility level mode Enabled the status machine of the equipment only considers for synchronization source a source that does not show timing flaws and where the Reversibility Time has expired If the quality prio...

Страница 74: ... source if there is no other source with a quality level equal to or better than the selected source Send Value after Quality Unknown Value to be sent if Quality Unknown The equipment will make the SSM output with the respective Quality Level configured if there is no synchronization source with a Quality Level other than Quality Unknown The quality level SSM is selected from a combo box Error No ...

Страница 75: ...eceived by the equipment When the SSM value is overridden the following precautions should be taken In case of interface LOS this source is not used If the received value is DNU the equipment will continue to use this synchronization source Sa bit Tx Allows setting the value of the transmission Sa bit in the case of 2Mbps only for the synchronization junctions Sa bit Rx Allows setting the value of...

Страница 76: ...cy Specify the clock Quality accuracy type Priority 1 Override criteria for best master clock selection 1 253 Priority 2 Specify a particular switch priority when criteria matches 1 253 Slave Only Enables slave only configuration of the PTP machine enable disable Two Step Clock Enables Two step clock configuration of the PTP machine enable disable Telecom Profile Enable If Enabled TeLecOm profile ...

Страница 77: ...og box to configure the PTP port to create Figure 5 30 Figure 5 30 Create PTP Port dialog box Parameter Description Admin PTP port administrative status Service Corresponding to an LSP previously created in the Services menu of the card where the 1588 synchronization will take place Role If the PTP port must act as Master only propagating synchronism or Slave only receiving synchronism Self IP Ori...

Страница 78: ...vices menu of the card where the 1588 synchronization will take place Table 5 17 Create PTP Port configuration parameters 5 2 4 5 Interfaces In CLI Interfaces related commands including configuration are described in section 7 6 10 interfaces node and subsections 5 2 4 5 1 PON Interfaces In this window it is possible to configure the GPON Interfaces Figure 5 31 PON interfaces configuration ...

Страница 79: ... Minimum Maximum Sets the distance for which the interface can detect ONTs The difference between the minimum and the maximum can t exceed 20km and the maximum distance can t be higher than 60km BER sec PON port Bit Error Rate in the downstream in sec Downstream FEC Flag Downstream FEC enabled at this PON port if selected Discover ONTs Flag Discover ONTs at this PON port enabled if selected Table ...

Страница 80: ...are described in section 7 6 10 3 lag sub node and subsections Figure 5 33 LAG interfaces configuration Parameter Description LAG Id Lag interface identifier Eth Id Ethernet Interfaces associated with the LAG Admin Port Administrative State Static Indicates if the LAG is Static doesn t transmit nor process LACPDU packets or dynamic transmits and processes LACPDU packets Load Balancing Criteria Tra...

Страница 81: ...ansmit nor process LACPDU packets or dynamic transmits and processes LACPDU packets Balance Traffic Load Balancing of the LAG interface there are three options SMAC Source MAC DMAC Destination MAC SMAC DMAC Source and Destination MAC Slot Indicates the Slot LC to which the ETH interface used in the LAG belongs to ETH Id Indicates th etherent interface used in the LAG Table 5 21 Mapping LAG interfa...

Страница 82: ...e Identifies the type of service Unicast Bidirectional service where each frame has only one final destination These services are used in Residential applications where some kinds of packets can be trapped and processed ex DHCP IGMP In case of Unstacked Services MAC Learning is preformed Multicast Unidirectional Service where one frame can be delivered to several destinations These destinations ar...

Страница 83: ... that when it s configured to the ONU VoIP configurations are downloaded to the ONT Bitstream Bidirectional Service where each frame has only one final destination These services are used in Business applications where all packets pass transparently by the system and MAC learning is disabled Mac Bridge In this type of service forwarding is based on S VID DMAC or S VID C VID DMAC Unicast Unknown Mu...

Страница 84: ... is possible to configure the p bits the scheduler type SP or WFQ and the bandwidth profile associated to each In CLI classes of services related commands including configuration are described in sections section 7 6 10 1 ethernet sub node subsection cos sub node section 7 6 10 2 gpon sub node subsection cos sub node and section 7 6 10 3 lag sub node subsection cos sub node Figure 5 38 Classes of ...

Страница 85: ... Figure 5 will open and it s possible to configure the p bit to class mapping Profile Identifies the Bandwidth profile used by the Class It s possible to have No Profile Scheduler Identifies the type of Scheduler used by the Class It can be Strict Priority or Weighted Fair Queuing Table 5 25 Classes of Service configuration parameters table Figure 5 39 PCP Class Mapping 5 2 4 9 Multicast Multicast...

Страница 86: ...t interfaces Robustness Specifies the number of retransmissions sent Should be adjusted for the expected packet loss on the network Unsolicited Report Interval Time interval between repetitions of a host s initial group membership report Max Records per Report Maximum number of group records that can be included in the same membership report Table 5 26 IGMP proxy configuration parameters Parameter...

Страница 87: ...rol Plane To check if the Data packets Data Plane are arriving to the OLT the user can activate the Active Channels Probes In CLI Multicast Probes related commands including configuration are described in 7 6 15 4 probes sub node and subsections Figure 5 42 Active channels Probes Configuration window Parameter Description Index Index of the Probe Admin Probe Administrative State Service Service to...

Страница 88: ...up Flag enable disable IP Address Active Group IP address Mask Active Group Mask Table 5 29 Group List Configuration parameters 5 2 4 10 MAC Tatble Switch In configuration sub menu MAC the Switch menu item opens Aging Time Configuration window Figure 5 45 In this window it is possible to configure the Aging Time which defines the maximum time each MAC address can be at the MAC table when no packet...

Страница 89: ...ck subrack slot port onuid svid Template circuit ID parameters variables and usable values are listed in Table 5 33 Access Node Id Display the access node identification Rack sub Rack Shelf Numeric coordinates of the equipment cabinet position Table 5 31 Global DHCP configuration parameters Parameter Description Service Choose an OLT service by ID Options 18 37 82 Enables the DHCP options in the s...

Страница 90: ...yer 2 Ports In CLI 5 2 3 14 IP Source Guard related commands including configuration are described in 7 6 12 ip source guard node and subsections Figure 5 47 IP source Guard Configuration window Parameter Description Admin IPsource Guard Filter administrative state Service Service to which the iP Source guard Filter applies selectable froma comobo box with all previously configured available servi...

Страница 91: ... related commands including configuration are described in section 7 6 1 acl node and subsections Figure 5 49 Access Lists configuration sub menu The selection of Access Lists Sub menu item Configuration opens an Access Control List window Figure 5 50 In this window it is possible to create access control lists configure port associations and services associations per access list ...

Страница 92: ...scription ACL ID Access List name Port Port associated to the access control list identified by the pair Port type and slot Admin Administrative status of the ACL sport association table entry Direction Traffic direction on the ACLs list associated port current value in Table 5 36 ACLs port association table parameters To configure ACLs port association the button Add should be used An ACls port a...

Страница 93: ...ion of service to the selected ACL list Figure 5 The use of Dialog Box Add button will add the configured ACLs services association to the ACLs services association table The Save button will save the change to the ACLs services association table Figure 5 52 ACLs service association configuration dialog box The selection of Access Lists Sub menu item Rules opens an Access Control List rule Configu...

Страница 94: ...ffic subject to the configured ACL Rule IP IPv4 Source address Mask IPv4 Source Mask Destination Destination Address for the traffic subject to the configured ACL Rule IP IPv4 Destination address Mask IPv4 Destination mask Table 5 39 Access Control List Rules IPv4 Standard Table parameters Parameter Description ACL Access control list name Name ACL Rule name Admin Administrative status of the ACL ...

Страница 95: ...llows the definition of the ethernet frame fields of the traffic subject to the rule Table 5 41 Access Control List Rules IPv6 Extended Table parameters Figure 5 54 ACL rule Details dialog box Parameter Description Rule ACL Rule Name Protocol Protocol of the traffic subject to the Rule Precedence Precedence of the traffic subject to the Rule TOS HEX TOS Mask HEX TOS HEX TOS Mask HEX of the traffic...

Страница 96: ...on Schemes configuration sub menu 5 2 4 14 1 Protection Schemes ETH Ring G 8032 The selection of Protection Schemes Sub menu item ETH Ring G 8032 opens an Ethernet Ring Protection G 8032 window Figure 5 56 In CLI ETH Ring G 8032 related commands including configuration are described in section 7 6 7 erp ring node and subsections Figure 5 56 Ethernet Ring Protection configuration window ...

Страница 97: ...ails Dialog Box Parameter Type Parameter Description General parameters Admin ERP administrative state Open Ring Open Ring Flag enable disable APS Channel VLAN VLAN used by the Automatic Protection Switch Channel MEG Level Maintenance Entity Group OAM level from 0 7 Operator 0 1 2 Provider 3 4 Customer 5 6 7 Ring Id ERP instance Id Revertive Revertive flag enable disable Wait to Restore min 1 to 1...

Страница 98: ...arameters Figure 5 58 Add ERP Instance Dialog box configuration parameters 5 2 4 14 2 Protection Schemes GPON Type B The selection of Protection Schemes Sub menu item GPON Type B opens a GPON Type B window Figure 5 59 In CLI GPON Type B related commands including configuration are described in section 7 6 9 gpon protection node and subsections Figure 5 59 GPON Type B Protection configuration windo...

Страница 99: ...stance configuration details Figure 5 60 Table 5 45 GPON Type B Protection window parameters Figure 5 60 GPON Type B protection Configuration details Dialog Box Parameter Type Parameter Description General parameters Admin GPON Type B protection Group administrative state Type Type GPON Type B protection configured current type 1 1 protection Reversibility Flag If selected indicates that the syste...

Страница 100: ...ion parameters Parameter Description Group GPON Type B Protection group identifier Admin GPON Type B Protection group administrative state Working GPON Type B working interface identified by pair Slot interface in the slot Protection GPON Type B protection interface identified by pair Slot interface in the slot Reversibility Flag If selected indicates that the system will switch back to the workin...

Страница 101: ...ion interface Reversibility Flag If selected indicates that the system will switch back to the working interface after a predefined period of time on the protection state following a switch over Wait to restore time Min Time in minutes on the protection state after a switch over before switching back to the working state in the case Reversibility is configured Holdoff time x100ms Time in multiples...

Страница 102: ...ck to the working state in the case Reversibility is configured Ports W ETH Group Working Ethernet Uplink port P ETH Group Protection Ethernet port Priority Switch over conditions priority level classification Condition Type of conditions selectable for switch over cause currently two high priority conditions can be configured to cause switch over to a protection state Generalized Line Card Failur...

Страница 103: ...uipment configuration sub menu has two items Figure 5 Discovery ONUs In CLI Remote Equipment related commands including configuration are described in section 7 6 17 remote eq node and subsections Figure 5 65 Remote equipment configuraton sub menu ...

Страница 104: ...ions In the OLT is possible to insert ONUs offline by a manual insertion specifying the line card GPON interface ONU ID and the serial number Figure 5 66 Remote equipment discovery In order to easily find remote equipment it is possible to apply one or a combination of filters Filter Description Local Module Line Card 2 19 PON GPON Interface 1 8 ONU ONU T Identifier 1 64 Status ONU T Status New Eq...

Страница 105: ...e It can be in one of the following states New Equipment The ONU T was discovered but isn t registered Registry Error An error occurred while registering the ONU T Operational The ONU T is in normal operating state Processing ONU T MIB SYNC is being performed in this state the ONU T doesn t accept any configuration Configuration Error An error occurred while configuring the ONU T Absent The ONU T ...

Страница 106: ... be preformed any automatic update FEC Upstream Flag if selected indicates FEC is used in the upstream direction Table 5 52 Inserting Equipment window parameters There are two different ways to insert a new ONU T Online Figure 5 68 In this case the ONU T is connected to the GPON Interface and is in New Equipment state To insert the ONU T the user must select the ONU T checkbox and press the Insert...

Страница 107: ...s In CLI ONUs related commands are described in section 7 6 17 6 ONUs sub node and subsections ONT configuration window is composed by the following tables ONU Selection System Parameters PON Interfaces Analog RF Interfaces VoIP Interfaces Services Figure 5 70 ONU Selection filter ...

Страница 108: ...s Parameter Description Equipment name Custom field used to tag the equipment should be unique among all equipments Example ONT1 1 Description Brief description of the equipment Serial Number ONU T Serial Number 16 Hexadecimal characters Contact Entity responsible for this equipment department person etc Location Custom field with the equipment location Hardware Version ONU T Hardware Version 14 c...

Страница 109: ...e following parameters Parameter Description Port Port identifier Admin Port Administrative State Media Type Link Speed and Duplex Autoneg 10BASE T Full Duplex 100BASE T Full Duplex 1000BASE T Full Duplex Flow Control Activates the transmission and processing of Pause Frames always disabled Loop Activates the Port loop always no loop Table 5 55 Ethernet Interfaces configuration table In CLI remote...

Страница 110: ...ns Figure 5 75 VoIP interfaces configuration The VoIP Interfaces configuration table is composed by the following parameters Parameter Description Port Port identifier Admin Port Administrative State Hold Over Time sec This parameter determines the time during which POTS loop voltage is held up when the ONT is not ranged on the PON When the ONT ranges successfully on the PON it restores POTS loop ...

Страница 111: ... contains the client configuration File in server File to be downloaded from the ftp server This is a xml file that contains the client configuration ex supported codec s number etc Table 5 58 VoIP Interfaces configuration window parameters In CLI remote equipment Services related commands are described in section 7 6 17 6 8 services sub node and subsections Figure 5 77 E1 Interfaces The E1 Interf...

Страница 112: ... the following parameters Parameter Description ONU Port ONU Port Service name Enable ON OFF Service OLT Service identifier INPUT TPID Identifies the Upstream profile associated to the service OUTPUT TPID Identifies the Downstream profile associated to the service DSCP to PCP Profile Inner VLAN ID client on the network facing Ethernet interface 1 4094 Operation Table In case this service is untagg...

Страница 113: ...his option must be active It s only possible to have a Native service by ONT port UNI C TAG VLAN ID delivered received from the Ethernet subscriber facing interface at the ONU 1 4094 In case the vlan in the client port is different from the one provisioned in OLT services the checkbox must be selected and the vlan value must be configured 1 4094 Det Det Table 5 62 Services configuration details To...

Страница 114: ...sections 5 2 4 16 1 System Services Time SettingsS Time Settings menu item opens a Clock and Timezone configuration window that is composed by two tables Clock Configuration where it s possible to configure the system clock If NTP is enabled it cannot be configured Timezones where it s possible to define the timezones used by the equipment and used by the Central Management Clock and Time zone rel...

Страница 115: ...he country and the region within the country Table 5 64 Timezones configuration parameters 5 2 4 16 2 System Services NTP In the NTP configuration window it is possible to activate the NTP in OLT and to configure the NTP servers NTP menu item opens a Network Time Protocol configuration window that is composed by two tables Figure 5 84 Global NTP that allows the activation of NTP in the OLT NTP Ser...

Страница 116: ...ions Figure 5 85 System Settings SNMP Agent window SNMP Service Table The Manager Configuration table is composed by the following parameters Parameter Description Service Activation Service Activation Flag Enable disable Must ne enable to activate the SNMP Service Management System Active Active Flag Enable disable Must be Enable to activate the management system defined in this table line IP Net...

Страница 117: ...Board Board is in conflict a different type of card is expected 5 Board Signal the NMS that a configuration has been made in the equipment e g via CLI or webTI for example 7 Interface SFP Fail 11 Equipment Loss of connectivity with the ONU 12 Equipment 48V present 13 Equipment Temperature alarm 16 Equipment System boot 18 Interface Loss of signal LOS 26 Interface Signal Degrade 50 Equipment Synchr...

Страница 118: ...detected on synchronism junction number one 452 Equipment LOMF detected on synchronism junction number two 542 Equipment LOS detected on synchronism junction number one 543 Equipment LOS detected on synchronism junction number two 556 Interface The input power of the EDFA is below the minimum threshold 557 Interface The input power of the EDFA is above the maximum threshold 558 Interface No signal...

Страница 119: ...make the upgrades MEP ID MAID Selects the MEP ID MAID to make the upgrades Admin Server Administrative State Level Selects the Level to make the upgrades Transmission period Selects the Transmission period to make the upgrades VLAN ID VLAN ID Details Details probe Table 5 70 CFM Probe configuration parameters In CLI CFM Probes related commands are described in section manager sub node probes sub n...

Страница 120: ...ONU s Software Image Files where it is possible to manage the ONU Firmware files In order to use ONT SW upgrade Auto mode an active SW version must be previously set as default for the respective ONT profile In the case there is no default SW version set for the ONT profile the following alarm message will be returned by the system SW and HW version mismatch when executing Auto ONT SW upgrade In C...

Страница 121: ...o select one or a group of ONT s to make upgrade Set default Set s the default version to some ONT profile HW version Table 5 72 Software Image Files configuration parameter The Out of Sync Files Button Figure 5 lists all files not synchronized with the local management These files are not presented in the Software Image Files Table The out of Sync files list is shown in a pop up window The user c...

Страница 122: ...s the apply file 1 in the commands column in the Software Image Files table Figure 5 93 There the user can choose which ONU we wants to make the upgrade only ONU s with SW Mode OFF will appear to select Pressing Update Button 2 will start Update for the configured selection 2 1 Figure 5 93 Selecting the ONU s to upgrade ...

Страница 123: ...mber of bytes transmitted In the end of the upload you can have Upload finished with error in case an error occurred or Upload finished successfully in case the file was well transferred To finish the ONU firmware upgrade the user must execute Commit and Activate by pressing the button No 2 Figure 5 94 Check ONU Upgrade Status 5 2 4 19 Backup Management Figure 5 95 Backup Management Configuration ...

Страница 124: ...up Manager Parameter Description File name Backup File name Date Time Backup date and time Description Backup description Table 5 73 Backup Manager Window parameters To create a System Database Backup Figure 5 96 The user must press the Create button 1 and the Backup dialog box will appear After filling the fields filename and description in the dialog box pressing the Apply button 2 will save the...

Страница 125: ...lize by Pressing the Save button 2 will save the Database in the OLT file system Figure 5 98 Save a Database Backup file to a PC To add a database stored in the PC Figure 5 99 Press the Add button 1 and the Send the Local Backup dialog Box will appear Pressing the empty field 2 the Choose file to Upload dialog box will appear allowing the selection of a file from a repository to upload to the OLT ...

Страница 126: ... Figure 5 100 Uploaded file available in the local backup table To restore a Database Figure 5 101 First the user must select the pretended Database to load 1 Then press the button Restore 3 After this the system will reboot and startup with the new Database ...

Страница 127: ...By pressing Delete Service Configuration button the system will delete service configuration and reset to factory defaults except for the inband activated ports included and outband management interfaces Figure 5 102 Delete Service Configuration Note Resetting to factory defaults DOES NOT REMOVE Created users Equipment configured IP address ...

Страница 128: ...ystem In the CLI section of this manual the users management related functionality is described section 7 6 21 users node and subsections Figure 5 103 Menu Configuration Item Users In the Change Password window it s possible for a user with administrator privileges to change the user password to access the system for any user in the user s list which is used Figure 5 104 Figure 5 104 Change of use...

Страница 129: ... version by checking the Firmware version at the equipment WEBTI interface main window with CLI and the command equipment system show 6 1 2 Upgrading to a New Software Release You can upgrade to a new software release for the OLT Ref 769401 Series OLT OS either using AGORA NG NMS system or using a LCT and CLI 6 1 3 OLT OS Installation Procedure Note In order to install OLT OS it is necessary to ha...

Страница 130: ...e information on the state of configured OLT elements and statistics Figure 6 1 Status menu In CLI status information is available at these sections 7 6 2 applications node subsection status command at firmware files subnode 7 6 4 cfm probe node subsection status command 7 6 6 equipment node subsection status command 7 6 6 4 system sub node Subsection status command 7 6 7 erp ring node subsection ...

Страница 131: ...A statistic sub node with counters information available by using command show is also present in sections 7 6 10 interfaces node subsections statistics sub node at Ethernet subnode statistics sub node at Ethernet services subnode statistics sub node at gpon subnode statistics sub node at lag subnode 7 6 15 multicast node subsection statistics sub node at probes subnode 7 6 17 remote eq node subse...

Страница 132: ...te Fan Module Figure 6 2 System State The System State table is composed by the following parameters Parameter Description Id The Id column is composed by Slot Identifies the number of the slot Name Identifies the kind of board inserted in the slot State Indicates the board state Temperature Indicates the board temperature ºC Resource Usage Indicates the resources in use CPU Memory Storage Table 6...

Страница 133: ...or each fan in the module Table 6 2 Fan Module Status parameter table 6 2 2 Synchronism The Synchronism status sub menu has two items Figure 6 4 Global PTP Figure 6 3 Status submenu Synchronism 6 2 2 1 Global Global menu item opens a Synchronism Status window that is composed by two tables Figure 6 4 Global Parameter Synchronism Sources Figure 6 4 Synchronism Status window ...

Страница 134: ...lot or junction number SSM Rx This column identifies the received SSM Synchronization Status Message SSM Used This column identifies the used SSM Signal Fail Signal failure of the respective synchronism source Attenuation Attenuation measured in dB associated with each of the existing synchronism junctions Command It is possible to temporarily remove a synchronism source attached to a selection pr...

Страница 135: ...ommand Force Switch at Global Parameters table Causes switching to the selected synchronism source even if it has a failure Thiscommandcanbeusedtoimplementthecurrentlyselectedsynchronismsource byassumingthatthesynchronism source is enabled and not in a Locked Up state Otherwise this command is automatically rejected This command overrides manual switching and another later Force Switch command ove...

Страница 136: ...ration of the PTP machine enable disable Clock Class Default clock Quality class 0 255 Clock Accuracy Clock Quality accuracy type OffSet Scaled Log Variance Parent DS Clock Identity Port Number Observed OffSet Scaled Log Variance Observed Clock Phase Change Rate Grand Master Clock Identity Grand Master Priority 1 Override criteria for best master clock selection 1 253 Grand Master Priority 2 Parti...

Страница 137: ...lowing parameters Parameter Description PON Id PON Interface identifier SFP SFP SFP SFP module By pressing the SFP SFP module it s possible to view the SFP SFP detailed information Figure 6 Tx Power dBm Indicates the transmitted optical power in dBm Rx Power dBm By pressing view the window will open Figure 6 and it s possible to visualize the received optical power from each ONT Current mA Indicat...

Страница 138: ...ower parameters Important Since the Received Optical Power measurement is slow the user has the possibility to start a measurement for all ONU s by pressing the Read All button Passing the mouse over the inserted SFP module identification displays module standard information Figure 6 8 in the example information for the standard GPON class B is displayed bitrate range and wavelength Figure 6 8 SFP...

Страница 139: ...EN 139 Figure 6 9 SFP Module detailed information Figure 6 10 GPON Interfaces Status ...

Страница 140: ...s Assured Assured Bandwidth must be less than 1 2Gb s Maximum Maximum Bandwidth CBR CBR Fixed Bandwidth must be less than 480Mb s Note Fixed plus Assured bandwidth must be less than 1 2Gb s Details By pressing in the pon Ethernet and errors a window with the respective counters will open Parameter Description PON Id GPON interface identifier Admin GPON interface administrative state Table 6 8 PON ...

Страница 141: ...ets from to the network PON Packets In this parameter is possible to check the GPON valid error dropped received transmitted packets from to the GPON PLOAM In this parameter is possible to check the GPON valid error dropped received transmitted PLOAM packets from to the network Table 6 9 GPON counters parameters By pressing the Ethernet link the following window will open Figure 6 12 Ethernet Coun...

Страница 142: ...ize over than 1518 bytes and with wrong FCS Frame Check Sequence Collisions Number of collisions in the Ethernet Segment only in Half Duplex Packets with 64 Octets Number of 64 bytes packets Packets with 65 to 127 Octets Number of packets with size between 65 to 127 bytes Packets with 128 to 255 Octets Number of packets with size between 128 to 255 bytes Packets with 256 to 511 Octets Number of pa...

Страница 143: ...ch of the ONT s upstream direction REI Errors received by each of the ONT s downstream direction Table 6 11 Port error statistics parameters 6 2 3 2 Ethernet Interfaces Status The selection of Interfaces item opens an Ethernet Interface Status window composed by the following tables Physical Interfaces Ethernet Interfaces Figure 6 14 Ethernet Interfaces Status ...

Страница 144: ...wer in dBm Rx Power dBm Indicates the received optical power in dBm Current mA Indicates the laser BIAS current in mA Temp ºC Indicates the XFP module temperature in ºC Laser Indicates the Laser operational States Table 6 12 Physical Interfaces Status parameters table Passing the mouse over the inserted SFP SFP module identification displays module standard information bitrate range and wavelength...

Страница 145: ...tes the Auto Negotiation State Media Type Indicates the Link Speed Collisions Not applicable in Full Duplex interfaces Status It s composed by the following columns Link Indicates the Link State Tx Indicates if the interface is transmitting packets Rx Indicates if the interface is receiving packets Statistics By pressing view a window with the port statistics according with RFC2819 will open Figur...

Страница 146: ...lisions Number of collisions in the Ethernet Segment only in Half Duplex Packets with 64 Octets Number of 64 bytes packets Packets with 65 to127 Octets Number of packets with size between 65 to 127 bytes Packets with 128 to 255 Octets Number of packets with size between 128 to 255 bytes Packets with 256 to 511 Octets Number of packets with size between 256 to 511 bytes Packets with 512 to 1023 Oct...

Страница 147: ...s if the LAG is Static in this case it doesn t process or send LACPDU s or it s Dynamic in this case it processes and send s LACPDU s Statistics By pressing view a window with the transmitted and received packets by each interface will open Figure 6 18 Table 6 15 LAG interfaces Status parameters Figure 6 18 LAG port statistics The LAG Port Statistics table is composed by the following parameters P...

Страница 148: ... pressing the counter for that specific PON port is activated by pressing the it s possible to view service specific counters If the Service is ofType Multicast IGMP Counters are also available Figure 6 21 Slot Indicates the Slot By pressing the it s possible to view service specific counters Only to Unicast services with DHCP Relay Agent Both differential values and Absolute values area available...

Страница 149: ...EN 149 Figure 6 20 DHCP counters ...

Страница 150: ...ets Without Options Option 82 Option 37 Option 17 Client Packets Trusted Number of dropped packets because they are client requests without options received in Trusted interfaces Network side Client Pack with Opts Untrusted Number of dropped packets because they are client requests with options received in Untrusted interfaces Client side Server Packets Untrusted Number of dropped packets because ...

Страница 151: ...Pv2 packets of type Join Invalid Join Leave V3 Number ofTransmitted and Received IGMPv3 packets Total and Partial counters displayed of type Membership Report Invalid Membership Report To Include To exclude Is Include Is Exclude Allow Block Invalid To Include Invalid To Exclude Invalid Is Include Invalid Is Exclude Invalid Allow Invalid Block Queries Number of transmitted and Received Queries Tota...

Страница 152: ...of Broadcast packets Dropped Total number of Dropped packets Table 6 20 Packets port statistics parameters 6 2 6 MAC Table The MAC Table Status sub menu has two items GPON Switch Figure 6 23 MAC Table Status sub menu 6 2 6 1 GPON GPON menu item opens a PON MAC Table window Figure 6 24 composed by two tables Filters selects criteria to visualize MAC addresses MAC table Learned client MAC addresses ...

Страница 153: ...d MAC address Table 6 21 Filter selection parameters The MAC address table is composed by the following parameters Parameter Description PON Indicates the PON interface ONU ID Indicates the ONU MAC Address Indicates the learned MAC address Total MAC entries Indicates the total number of MAC entries in the table Table 6 22 MAC address parameters For each GPON interface it s possible to learn up to ...

Страница 154: ...ring by ONU ID the desired ONU ID must be typed in Service Selection of Service Id to filter from a list of available Services MAC Address Selection of MAC address to filter by introducing the desired MAC address Table 6 23 Filters selection parameters The MAC address table is composed by the following parameters Parameter Description Port Indicates the Port ONU ID Indicates the ONU Service Indica...

Страница 155: ...ilable Services ONU ID Selection ONU ID to filter by introducing the desired ONU ID IP Version Selection of IP version IPv4 or IPv6 IPv4 IPv6 Selection of IPv4 IPv6 address to filter by introducing the desired IPv4 IPv6 address MAC Address Selection of MAC address to filter by introducing the desired MAC address Table 6 25 DHCP Relay filter selection parameters The DHCP Relay List is composed by t...

Страница 156: ...ze the Multicast IP Groups present at OLT as well as the customers that are watching them The List of active groups can be very large in which case filters can be used to display a list Active Groups according to the selection criteria defined in the filter Figure 6 28 Active Groups window In order to visualize status information for an active group the multicast service associated to the group mu...

Страница 157: ...ctive Groups selection filter configuration parameters The Active Groups table is composed by the following parameters Parameter Description Service Indicates the name of the Multicast Service Static Yes for a static Group selection IP Address Indicates the Multicast Group IP address Details By pressing Details a dialog box with the active users watching the Multicast Group will open A selection f...

Страница 158: ...Service and IP filters to be easier to sort the desired probe s Figure 6 31 Status Multicast Probes window and Statistics The Probes List table is composed by the following parameters Parameter Description Index Indicates the Probe Index Admin Indicates the Probe Administrative State Enable Disable Service Indicates the name of the Multicast Service IP Address Indicates the Multicast Group IP addr...

Страница 159: ... Counters Figure 6 39 GEM Port Counters Figure 6 38 Service Counters Figure 6 39 Software Images and Maintenance Figure 6 43 T CONT Figure 6 44 The ONU Selection table Figure 6 32 allows the setting of criteria to filter the ONUs for which status information will be displayed in the remaining tables Figure 6 32 ONUs Status window selection table Parameter Description PON Port Indicates the PON Por...

Страница 160: ...table is composed by the following parameters Parameter Description Drop Events Number of dropped packets Octets Number of bytes Packets Number of Packets Unicast Packets Number of Unicast Packets Broadcast Packets Number of Broadcast Packets Multicast Packets Number of Multicast Packets CRC Align Errors Number of packets with wrong FCS Frame Check Sequence Undersize Packets Number of packets with...

Страница 161: ...able Figure 6 35 Analog RF Interfaces table The Analog RF Interfaces Status table is composed by the following parameters Parameter Description Port Indicates the Analog RF Port Admin Indicates the Administrative State Operational State Indicates the Port Operational State Table 6 33 Analog RF Interfaces parameters Figure 6 36 GPON Interface table The GPON Interfaces table is composed by the follo...

Страница 162: ...r of received dropped packets Packets received Indicates the number of received packets Blocks received Indicates the number of received GEM blocks Blocks transmitted Indicates the number of transmitted GEM blocks Table 6 36 GEM Port Counters parameters In the Service Counters table there are the counters associated to each client taking into account the Service and ClientVlans By pressing the lin...

Страница 163: ...ion Name Service Indicates the Service Name Statistics Control Packets By pressing the links it s possible to view Control Plane Packets associated with the service Statistics Total Packets By pressing the links it s possible to activate deactivate view Data Plane Packets associated with the service Figure 6 40 Service Counters parameters table Figure 6 41 DHCP Statistics per client service ...

Страница 164: ...ons Option 82 Option 37 Option 18 Client Packets Trusted Number of dropped packets because they are client requests without options received in Trusted interfaces Network side Client Packets with Opts Untrusted Number of dropped packets because they are client requests with Options received in Untrusted interfaces Client side Server Packets Untrusted Number of dropped packets because they are serv...

Страница 165: ...pe Membership Report Invalid Membership Report To Include To exclude Is Include Is Exclude Allow Block Invalid To Include Invalid To Exclude Invalid Is Include Invalid Is Exclude Invalid Allow Invalid Block Queries Number of transmitted and Received Queries Total and Partial counters displayed General of type General queries Group Specific of type Group specific queries Group and Source Specific o...

Страница 166: ...ted version will change Valid Indicates if the SW FW version is Valid Version Indicates the SW FW version name Maintenance Indicates the Firmware Download state Alarm Indicates the state of the last upgrade Command Command to stop upgrading the ONT s FW Table 6 39 Software Images and Maintenance parameters Figure 6 44 T CONT table The T CONT table is composed by the following parameters Parameter ...

Страница 167: ...n opens a window composed of an Ethernet Ring Protection status table with information on the working and protection instances part of the Ethernet protection ring scheme It is possible in this window to Check which of instances and interfaces are in the protection state View details on the APS channel status View the configured values for the timers Send commands to force maintain or clear Ring p...

Страница 168: ...ime Shows configured guard timer value Wait to Restore Shows configured Wait to Restore timer value Wait to Block Shows configured Wait to Block timer value Holdoff Time Shows configured Holdoff timer value Commands Send link selection sends the command chosen from a combo box Available commands are Clear clear switching FS Force switching MS Maintain switching Table 6 41 ERP Instance Configuratio...

Страница 169: ... RPL Blocked State Do not Flush Visual indicator on Do not Flush message Blocked Port Reference Blocked port reference ID Table 6 43 APS Channel TX per port detailed status parameters 6 2 10 2 GPON Type B Protection The selection of Protection Schemes Sub menu item GPON Type B opens a GPON Type B Protection window Figure 6 49 Figure 6 49 GPON Type B Protection Status window ...

Страница 170: ...otection window parameters 6 2 10 4 Ethernet Protection The selection of Protection Schemes Sub menu item ETH Port opens an Ethernet Protection Status window Figure 6 50 Ethernet Protection Status window Parameter Description Group Ethernet port protection group Interface Interfaces part of the protection group Status Interface Operational status Active Interface Indicates the active interface Syn...

Страница 171: ...ive time ms Instant of time of arrival of last received CCM packet Alarms Tx This alarms triggers when no packets are transmitted Rx This alarms triggers when no packets are received Table 6 46 CFM probes list parameters Parameter Description Port Physical interface that the probe is monitoring MEP ID MEP Identification forwarded by the probe in the CCM message RMEP ID MEP ID of the remote MEP wit...

Страница 172: ...Expiration Time Time after which the user access permission is no longer valid Commands Commands Table 6 48 Users List parameters 6 3 Logs The Logs menu consists on a sub menu Alarms composed by a Global Item and an item for each of the line cards inserted in the OLT Figure 6 53 Figure 6 53 Logs menu Alarms sub menu In the CLI section of this manual the Logs related features are described in secti...

Страница 173: ... administratively up the alarms related to it won t be registered The following filtering parameters can be applied Parameter Description Code Alarm Code Index Port or interface where the alarm or event occurred Date and Hour It s possible to select a beginning ending or interval to visualize the alarms and events Description Alarm or event description Equipment Alarm or event source Table 6 49 Fi...

Страница 174: ...r interface where the alarm or event occurred Date and Hour Date and hour when the alarm or event occurred Code Alarm Code Description Alarm or event description Table 6 50 Event List parameters In the end of the table there are two buttons Refresh updates the table Delete Deletes all the alarms ...

Страница 175: ... using a configured management VLAN which interconnects MPLS network to DCN 7 2 Access to the Equipment Any OLT equipment comes with an integrated Command Line Interface CLI for system management and configuration In order use the CLI OLT interface the OLT equipment must accessed via Telnet or SSH protocols using the console port RS232 An SSH telnet client application as for example PuTTY which is...

Страница 176: ...e equipment and of the accesses to the system users list and permissions Standard OLT configuration permission cannot view or manage the system users list Guestuser Permission to view The default password is the same as the user login Only the user with admin privileges can change users passwords Typing the login and password at the session opened in the OLT System the user is presented with the C...

Страница 177: ...and full path must be used History of last used commands is available by pressing the arrows keys up down The cd command operates as in UNIX cd returns to the root node cd navigates up and so on 7 3 2 1 General Usage Commands Set of commands to improve CLI usability by providing generic navigation and help information Help Figure 7 3 Provides basic and generic command usage description typed follo...

Страница 178: ...quipment system config Usage CONFIG Global system configuration OPTIONAL access node Access Node ID alarm rep mode Define the alarm reporting mode none snmp xml cd ip auto update Automatically upgrades the second matrix enable disable contact Set contact information as appropriate date Set the system date as YYYY MM DD UTC description Set a description in this context location Set the system locat...

Страница 179: ...entity on the node where the command was executed Table 7 1 Common Usage Commands 7 3 2 3 Command Structure A command has a name and may have arguments parameters of type mandatory or optional For the execution of the command command name must be used and if existing mandatory arguments with the correct command syntax Use Description Command Command name Parameters s Parameters can be mandatory or...

Страница 180: ...ay generic navigation help information Figure 7 3 dir command list the node available commands and sub nodes Figure 7 8 cli dir cd clear dir help mem quit show showconfig tree acl applications backup manager cfm probe dhcp equipment erp ring eth protection gpon protection interfaces ip ip source guard logs mac table multicast profiles remote eq routing services synchronism users utils Figure 7 8 d...

Страница 181: ...full list of sub nodes and available commands per node sub node Figure 7 10 cli applications tree applications firmware upgrade files check config export import remove show status onu upgrade apply file availableValues execute manager config show showconfig olt upgrade apply file import time ntp config create disable enable remove show showconfig time zone availableValues config show showconfig Fi...

Страница 182: ...en displayed showing which slots have information available in a table format in this case Figure 7 14 Slots with YES in the Details column has information available Figure 7 14 Output of show command without arguments In some situations there is a specific command only to show the possible values for each argument For example on the node services the command availableValues displays to which slot...

Страница 183: ...To see gpon packet statistics and link status we have gpon statistics gpon show gpon statistics ethernet show gpon statistics errors show Note that in this last case the interfaces gpon sub node statistics itself does not allow any command There are also interfaces gpon sub nodes cos dhcp and multicast that allow to manage respectively CoS DHCP and Multicast configurations for the GPON interfaces ...

Страница 184: ...tem shows the command line that should be used to configure in the system the current configuration Table 7 4 Common Usage Commands cli applications time time zone showconfig applications time time zone config central manager time zone Europe Lisbon local time zone Atlantic Azores Figure 7 17 showconfig command screen output example 7 4 4 Invalid Characters The following special characters are not...

Страница 185: ... usage of configuration scripts Configuration scripts are ordered sequences of commands with a certain operational objective Configuration scripts can be written and be pasted in the CLI prompt as Plain text Copy and paste at the CLI prompt is possible either for a single command or for a sequence of commands Script thus allowing the usage of scripts Pressing enter after copying a command or scrip...

Страница 186: ... eth pon voip lag Port number integer 7 4 7 2 Arguments ID and admin ID The argument ID is a very common argument Whenever this argument is present there is also a show command available whose table will have an ID column This argument is used to specify a single table entry for further configuration or information admin The admin argument is used to configure the administrative state of entities ...

Страница 187: ...fines the three arguments slot port ontID and values in a single operation A command in this node sub tree remote equipment uses this information as needed Configuration on a connected ONT with other different argument Slot Port ontID values than those defined in the initial connect command arguments takes precedence over the information stored in the connect command ...

Страница 188: ... import remove show status onu upgrade apply file availableValues execute manager config show olt upgrade apply file import time ntp config create disable enable remove show showconfig time zone availableValues config show showconfig backup manager create del serv conf export import remove restore show cfm probe config create remove show showconfig status unx ccm remove show dhcp dhcp services con...

Страница 189: ...ig create remove show showconfig onu config create remove show showconfig upstream config create remove show showconfig voip server availableValues config create remove show showconfig specific config create remove show showconfig remote eq config onu id connect disconnect showconnected discovery change reg type command config create insert insert all reboot reboot all remove remove all show onu s...

Страница 190: ...g create remove show status global command show sources command show ptp show users config create remove show status 7 6 Nodes Sub Nodes and Commands 7 6 1 acl node cli acl tree acl config create remove show showconfig interface add config remove network service add config remove rule config remove rule ipv4 ext config create show rule ipv4 std config create show rule ipv6 ext config create show r...

Страница 191: ...ate a new ACL Full path acl create Mandatory Parameters type Screen Output No Table 7 6 create command information cli acl create Usage CREATE Create a new ACL MANDATORY type Identifies the type of an ACL mac ipv4 std ipv4 ext ipv6 ext OPTIONAL ID Identifies a table entry by ID in this context admin Administrative State Enable disable in this context enable disable name Identifies the name of an A...

Страница 192: ...e current ACLs configured OPTIONAL type Identifies the type of an ACL mac ipv4 std ipv4 ext ipv6 ext Figure 7 26 CLI on line help on show command usage in this node context Figure 7 27 Output of show command without arguments in this node context Parameter Group Parameter Description ACL ID ACL identification number Type ACL type text Rules Number of existing rules for the ACL ID table entry numbe...

Страница 193: ...e sub node 7 6 1 6 1 add command Name add Description Associate a given Interface to an ACL Full path acl interface add Mandatory Parameters acl id port Screen Output No Table 7 11 add command information cli acl interface add Usage ADD Associate a given Interface to an ACL MANDATORY acl id Identifies an ACL by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 OPTION...

Страница 194: ...ction Identifies an ACL Rule by ID in this context Figure 7 30 CLI on line help on config command usage in this node context 7 6 1 6 3 remove command Name remove Description Remove an existing Interface association Full path acl interface remove Mandatory Parameters acl id port Screen Output No Table 7 13 remove command information cli acl interface remove Usage REMOVE Remove an existing Interface...

Страница 195: ...an ACL Rule by ID in this context Figure 7 32 CLI on line help on add command usage in this node context 7 6 1 7 2 config command Name config Description Configure an existing Network Service association Full path acl network service config Mandatory Parameters acl id serviceID Screen Output No Table 7 15 config command information cli acl network service config Usage CONFIG Configure an existing ...

Страница 196: ...lp on remove command usage in this node context 7 6 1 8 rule sub node 7 6 1 8 1 config command Name config Description Configure any shared rule parameters Full path acl rule config Mandatory Parameters acl id rule id Screen Output No Table 7 17 config command information cli acl rule config Usage CONFIG Configure any shared rule parameters MANDATORY acl id Identifies an ACL by ID in this context ...

Страница 197: ...xisting rule MANDATORY acl id Identifies an ACL by ID in this context rule id Identifies an ACL Rule by ID in this context Figure 7 36 CLI on line help on remove command usage in this node context 7 6 1 9 rule ipv4 ext sub node 7 6 1 9 1 config command Name config Description Configure an existing IPv4 Extended Rule Full path acl rule ipv4 ext config Mandatory Parameters acl id rule id Screen Outp...

Страница 198: ...ING 31 precedence Match IP precedence value not used 0 7 protocol Match the protocol number Protocol field of the IPv4 header not used 0 255 src ipv4 addr Source IPv4 Address src ipv4 mask Source IPv4 Mask src port end Specify Source L4 port number not used 0 65535 src port start Specify Source L4 port number not used 0 65535 tos Specify match condition based on IP TOS Mask value Two digit hexadec...

Страница 199: ...c ipv4 addr Source IPv4 Address src ipv4 mask Source IPv4 Mask src port end Specify Source L4 port number not used 0 65535 src port start Specify Source L4 port number not used 0 65535 tos Specify match condition based on IP TOS Mask value Two digit hexadecimal number 0000 0XFF tos mask Specify match condition based on IP TOS value Two digit hexadecimal number 0000 0XFF Figure 7 38 CLI on line hel...

Страница 200: ...number Admin ACL Administrative status Action Action implemented by the rule permit deny Parameter Value Table 7 22 show command output table parameters 7 6 1 10 rule ipv4 std sub node 7 6 1 10 1 config command Name config Description Configure an existing IPv4 Standard Rule Full path acl rule ipv4 std config Mandatory Parameters acl id rule id Screen Output No Table 7 23 config command informatio...

Страница 201: ...create command Name Create Description Create a new IPv4 Standard Rule for a given ACL ID Full path acl rule ipv4 std create Mandatory Parameters acl id action Screen Output No Table 7 24 create command information cli acl rule ipv4 std create Usage CREATE Create a new IPv4 Standard Rule for a given ACL ID MANDATORY acl id Identifies an ACL by ID in this context action permit or deny OPTIONAL admi...

Страница 202: ...on line help on show command usage in this node context Figure 7 44 Output of show command without arguments in this node context Parameter Description ACL ID ACL identification number Rule ID Rule identification number Rule Name Rule name Admin ACL Administrative status Action Action implemented by the rule permit deny Source IP Source IPv4 address Source Mask Source IPv4 mask Table 7 26 show com...

Страница 203: ...nation L4 port number not used 0 65535 flow label Match IPv6 flow label field not used 0 1048575 name Set a name for a specific Rule STRING 31 protocol Match the protocol number Protocol field of the IPv4 header not used 0 255 src ipv6 addr Source IPv6 Address src ipv6 prefix Source IPv6 prefix length 0 128 src port end Specify Source L4 port number not used 0 65535 src port start Specify Source L...

Страница 204: ...r not used 0 255 rule id Identifies an ACL Rule by ID in this context src ipv6 addr Source IPv6 Address src ipv6 prefix Source IPv6 prefix length 0 128 src port end Specify Source L4 port number not used 0 65535 src port start Specify Source L4 port number not used 0 65535 Figure 7 46 CLI on line help on create command usage in this node context 7 6 1 11 3 show command Name show Description Show t...

Страница 205: ...NDATORY acl id Identifies an ACL by ID in this context rule id Identifies an ACL Rule by ID in this context OPTIONAL action permit or deny admin Administrative State Enable disable in this context enable disable cos Match condition based on the CoS value not used 0 7 dst mac addr Destination MAC address in the format AA BB CC DD EE FF dst mac mask Destination MAC mask in the format AA BB CC DD EE ...

Страница 206: ...E FF ethernet type Four digit hexadecimal number to specify an Ethertype value not used 0X600 0XFFFF name Set a name for a specific Rule STRING 31 rule id Identifies an ACL Rule by ID in this context src mac addr Source MAC address in the format AA BB CC DD EE FF src mac mask Source MAC mask in the format AA BB CC DD EE FF Figure 7 50 CLI on line help on create command usage in this node context 7...

Страница 207: ...s Destination MAC Mask Destination MAC mask Table 7 34 show command output table parameters 7 6 2 applications node cli applications tree applications firmware upgrade files check config export import remove show status onu upgrade apply file availableValues execute manager config show showconfig olt upgrade apply file import time ntp config create disable enable remove show showconfig time zone a...

Страница 208: ...s fileID Screen Output No Table 7 36 config command information cli applications firmware upgrade files config Usage CONFIG CONFIG Configure information for a given file ID MANDATORY fileID Identifies a file by ID in this context OPTIONAL asw version Set the active software version for a given file STRING 31 description Set a description for the specified file STRING 47 hw version Set the hardware...

Страница 209: ...nd information Usage IMPORT IMPORT Import a new file from a TFTP server MANDATORY file name Specify the file name STRING 47 ip address IPv4 address profileID Identifies a profile by ID remote file The Path to file on the TFTP server STRING 255 sw version Set the software version for a given file STRING 31 OPTIONAL asw version Set the active software version for a given file STRING 31 description S...

Страница 210: ... applications firmware upgrade files show Usage SHOW Show the current ONU firmware files OPTIONAL fileID Identifies a file by ID in this context Figure 7 59 CLI on line help on show command usage in this node context Figure 7 60 Output of show command without arguments in this node context Parameter Description ID File identification number Name File name text Size Bytes File size Bytes Default Id...

Страница 211: ...ribed in Table 7 43 Table 7 42 status command information cli applications firmware upgrade files status Usage STATUS Display existing problems with the file repository Figure 7 62 CLI on line help on status command usage in this node context Figure 7 63 Output of status command in this node context Parameter Description ID File identification number Name File name text Status File status If Ok no...

Страница 212: ...NAL activate The ONU reboots and starts up with this image The default boot image is not modified enable disable commit This image will be set to be the default boot image enable disable onuID Identifies an ONU by ID Not used means all ONUs port Identifies an interface on the given slot only PON interfaces are available Not used means all PONs Figure 7 64 CLI on line help on apply file command usa...

Страница 213: ... Screen Output No Table 7 47 execute command information cli applications firmware upgrade onu upgrade execute Usage EXECUTE Will update firmware on all the ONUs in the given slot port OPTIONAL auto Send firmware to all ONUs that have software version set to auto enable disable planned Send firmware to all ONUs that have software version set to planned enable disable port Identifies an interface o...

Страница 214: ...manager config Mandatory Parameters ID Screen Output No Table 7 48 config command information cli applications manager config Usage CONFIG Configure management information MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable buffer size Specify the trap buffer size in bytes informs only interval Wait the speci...

Страница 215: ...size bytes trap buffer size Interval s Waiting period of time before re sending the trap when no ACK is received Retries Number of retries before skipping the current trap Table 7 50 show command output table parameters 7 6 2 3 olt upgrade sub node 7 6 2 3 1 apply file command Name apply file Description Updates OLT OS with the last imported setup file The system will reboot to use the new image F...

Страница 216: ...address OPTIONAL ip port Identifies the IP port number to use 1 65535 Figure 7 72 CLI on line help on import command usage in this node context 7 6 2 4 time sub node This sub node can be used to update the firmware of several ONTs in one operation in applications firmware upgrade onu upgrade node The applications firmware upgrade files node is used to manage the local firmware repository 7 6 2 4 1...

Страница 217: ...Table 7 54 create command information cli applications time ntp create Usage CREATE Create MANDATORY ip address IPv4 address name Define a name for this NTP server STRING 15 OPTIONAL admin Administrative State Enable disable in this context enable disable Figure 7 74 CLI on line help on create command usage in this node context 7 6 2 4 1 3 disable command Name disable Description Disable global NT...

Страница 218: ... applications time ntp remove Mandatory Parameters ID Screen Output No Table 7 57 remove command information cli applications time ntp remove Usage REMOVE Remove MANDATORY ID Identifies a table entry by ID in this context Figure 7 77 CLI on line help on remove command usage in this node context 7 6 2 4 1 6 show command Name show Description Shows the current configuration Full path applications ti...

Страница 219: ...rameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 60 showconfig command information cli applications time ntp showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration Figure 7 80 CLI on line help on showconfig command usage in this node context 7 6 2 4 2 time zone sub node This sub node allows the c...

Страница 220: ... output of availableValues command in this node context Parameter Description ID Time Zone identifier number Time Zone Name Time Zone identifier name Time Zone description Indicates region to which the indicated time zone is applicable Table 7 62 availableValues command output table parameters 7 6 2 4 2 2 config command Name config Description Configures time zone information Full path application...

Страница 221: ...ime zone configuration Full path applications time time zone show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 table parameters described Table 7 Table 7 64 show command information cli applications time time zone show Usage SHOW Display the current time zone configuration Figure 7 84 CLI on line help on show command usage in this node context Figure 7 85 Output...

Страница 222: ...ckup file from the current system state Full path backup manager create Mandatory Parameters No Screen Output No Table 7 67 create command information cli backup manager create Usage CREATE Creates a new backup file from the current system state OPTIONAL description Set a description for the new backup file Cannot be modified later STRING 63 Figure 7 87 CLI on line help on create command usage in ...

Страница 223: ...4 import command Name import Description Get a previously exported backup file from a TFTP server Full path backup manager import Mandatory Parameters remote file server ip Screen Output No Table 7 70 import command information Usage IMPORT IMPORT Get a previously exported backup file from a TFTP server MANDATORY remote file The Path to file on the TFTP server STRING 255 server ip The TFTP server ...

Страница 224: ...ion cli backup manager restore Usage RESTORE Apply a backup file to the current system The equipment will reboot MANDATORY local file A file name on the local repository STRING 63 Figure 7 92 CLI on line help on restore command usage in this node context 7 6 3 7 show command Name show Description Display a table with all existing backup files Full path backup manager show Mandatory Parameters This...

Страница 225: ...file short description Table 7 74 show command output table parameters 7 6 4 cfm probe node cli cfm probe tree cfm probe config create remove show showconfig status unx ccm remove show Figure 7 95 cfm node tree 7 6 4 1 config command Name config Description Configure a specific CFM probe Full path cfm probe config Mandatory Parameters ID Screen Output No Table 7 75 config command information ...

Страница 226: ...e Maintenance Domain MD Name according to IEEE 802 1ag mep Specify MEP Id port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 rmep Specify RMEP Id sma format Specify the Short MA Name Format primary vid string integer rfc2685 vpn id sma name Specify the short MA Name according to IEEE 802 1ag transmission period Specify the transmission period 10ms 100ms 1s 10s 1min 10min vlan Choose a V...

Страница 227: ... MA Name according to IEEE 802 1ag transmission period Specify the transmission period 10ms 100ms 1s 10s 1min 10min vlan Choose a VLAN ID Figure 7 97 CLI on line help on create command usage in this node context 7 6 4 3 remove command Name remove Description Remove an existing CFM probe Full path cfm probe remove Mandatory Parameters ID Screen Output No Table 7 77 remove command information cli cf...

Страница 228: ...monitoring MEP MEP Identification forwarded by the probe in the CCM message RMEP MEP ID of the remote MEP with which this probe makes P2P Level Probe OAM level from 0 7 Operator 0 1 2 Provider 3 4 Customer 5 6 7 Transmission Period Forwarding period of the CCM frames MEG ID MAID Identification of the CFM maintenance group VLAN VLAN that encapsulates the CCM frame sent by the probe Table 7 79 show ...

Страница 229: ...M probes status Figure 7 103 CLI on line help on status command usage in this node context Figure 7 104 Output of status command in this node context Parameter Description Slot Slot to which the monitored Physical interface belongs to ID CFM probe ID Admin CFM probe administrative state Port Physical interface that the probe is monitoring MEP MEP Identification forwarded by the probe in the CCM me...

Страница 230: ...ived Figure 7 105 CLI on line help on remove command usage in this node context 7 6 4 7 2 show command Name show Description Shows a list of Unexpected CCMs received Full path cfm probe unx ccm show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 107 Table parameters description in Table 7 85 Table 7 84 show command information cli cfm probe unx ccm show Usage SHOW...

Страница 231: ...pected CCM Packet type occurrences Table 7 85 show command output table parameters 7 6 5 dhcp node 7 6 5 1 Circuit ID template String Syntax The Syntax for the circuit ID template string is the following accessnodeid PON rack subrack slot port onuid svid Template circuit ID parameters variables and usable values are listed in the following table Parameter Variable Value Access Node accessnodeid St...

Страница 232: ...5 dhcp op18 Enable or disable the DHCP Op 18 enable disable dhcp op37 Enable or disable the DHCP Op 37 enable disable dhcp op82 Enable or disable the DHCP Op 82 enable disable eth priority pbit value in the DHCP packets 0 n 7 use global If enabled this service will use the global circuit id string enable disable Figure 7 109 CLI on line help on config command usage in this node context 7 6 5 2 2 s...

Страница 233: ...late used for the service if Use Global Disabled Table 7 89 show command output table parameters 7 6 5 2 3 showconfig command Name showconfig Description Show DHCP services information Full path dhcp dhcp services showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 90 showconfig co...

Страница 234: ... This command has no parameters Screen Output Text string Figure 7 115 Template string parameter description in Table 7 86 Table 7 92 show command information cli dhcp global show Usage SHOW Show DHCP global configuration Figure 7 114 CLI on line help on show command usage in this node context cli dhcp global show Global DHCP circuit ID Template String accessnodeid PON rack subrack slot port onuid...

Страница 235: ...ve Usage REMOVE REMOVE Remove DHCP leases from the Table MANDATORY mac Identify Set a MAC entry in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 serviceID Select an OLT service by ID Figure 7 117 CLI on line help on remove command usage in this node context 7 6 5 4 2 show command Name show Description Show DHCP leases information Full path dhcp leases show Mandatory Pa...

Страница 236: ...us boards config reboot show showconfig slot apply config show showconfig switch fabric show switch update upgrade sw system config reboot show showconfig status Figure 7 120 equipment node tree Sub node boards 7 6 6 1 status command Name status Description Show the current equipment status Full path equipment status Mandatory Parameters This command has no parameters Screen Output Table Figure 7 ...

Страница 237: ...ters admin slot Screen Output No Table 7 99 config command information cli equipment boards config Usage CONFIG Configure HW slotsbo MANDATORY admin Administrative State Enable disable in this context enable disable slot Identifies a slot Figure 7 123 CLI on line help on config command usage in this node context 7 6 6 2 2 reboot command Name reboot Description Send the reboot command to one board ...

Страница 238: ...tput Tables Figure 7 126 Tables parameter description in Table 7 102 Table 7 101 show command information cli equipment boards show Usage SHOW Show the current configuration Figure 7 125 CLI on line help on show command usage in this node context Figure 7 126 Output of show command in this node Parameter Description Slot Slot number Name Board Name State Slot State Admin Board administrative State...

Страница 239: ...nforces the current configuration Figure 7 127 CLI on line help on showconfig command usage in this node context 7 6 6 3 slot sub node 7 6 6 3 1 apply command Name apply Description Applies the current configuration to the HW Full path equipment slot apply Mandatory Parameters This command has no parameters Screen Output No Table 7 104 apply command information cli equipment slot apply Usage APPLY...

Страница 240: ...guration Figure 7 130 CLI on line help on show command usage in this node context Figure 7 131 Output of show command in this node context Parameter Description Slot Slot number Card Name Name of the card in the specified slot Card Status Card status newboard operational configuration error absent proc Admin Board administrative State Config Mode Configured mode on card Mode A Mode B Mode C FW Mod...

Страница 241: ...obal system parameters OPTIONAL access node Access Node ID STRING 63 alarm rep mode Define the alarm reporting mode none snmp xml auto update Automatically upgrade the second matrix enable disable contact Set the OLT contact information as appropriate STRING 31 date Set the system date as YYYY MM DD UTC description Set the global OLT system description STRING 63 location Set the OLT location infor...

Страница 242: ... help on reboot command usage in this node context 7 6 6 4 3 show command Name show Description Show the current global system configuration Full path equipment system show Mandatory Parameters This command has no parameters Screen Output Tables Figure 7 136 Tables parameter description Table 7 112 Table 7 111 show command information cli equipment system show Usage SHOW Show the current global sy...

Страница 243: ...ly Upgrade the second Matrix enabled disabled Table 7 112 show command output table parameters 7 6 6 4 4 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path equipment system showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configurat...

Страница 244: ...he AC Power Sensor State OK NOK Sensor 2 Open Door Sensor Indicates the Open Door Sensor State Closed door Open door Table 7 115 status command output table parameters 7 6 7 erp ring node cli erp ring tree erp ring config create remove show showconfig status command show aps channel show Figure 7 116 erp ring node tree 7 6 7 1 config command Name config Description Configure an existing ERP instan...

Страница 245: ...not enable disable p0 cfm probe id Identify a CFM probe by ID 0 for none p0 port Identify a Port e g eth 1 pon 3 lag 2 p0 slot Identify a Slot not used for LAG p0 type Set the port type non rpl rpl rpl neighbor p1 cfm probe id Identify a CFM probe by ID 0 for none p1 port Identify a Port e g eth 1 pon 3 lag 2 p1 slot Identify a Slot not used for LAG p1 type Set the port type non rpl rpl rpl neighb...

Страница 246: ...lot not used for LAG p0 type Set the port type non rpl rpl rpl neighbor p1 cfm probe id Identify a CFM probe by ID 0 for none p1 port Identify a Port e g eth 1 pon 3 lag 2 p1 slot Identify a Slot not used for LAG p1 type Set the port type non rpl rpl rpl neighbor revertive Specify is reversion is enabled enable disable ring id Set the ring ID wtr Set the Wait to Restore time 1 12 x10ms Figure 7 14...

Страница 247: ...Figure 7 145 Output of show command without arguments in this node context Parameter Description ID ERP instance Id Admin ERP administrative state Ring ID ERP Id Open Ring Open Ring Flag enable disable Revertive Revertive flag enable disable APS Channel VLAN VLAN used by the Automatic Protection Switch Channel MEG level Maintenance Entity Group OAM level from 0 7 Operator 0 1 2 Provider 3 4 Custom...

Страница 248: ...fault value 500ms P0 Slot Interface P0 ERP port identified by pair Slot interface in the slot Type ERP interface classification RPL Non RPL RPL Neighbor CFM Probe ID P1 Slot Interface P1 ERP port identified by pair Slot interface in the slot Type ERP interface classification RPL Non RPL RPL Neighbor CFM Probe ID APS Channel VLAN VLAN used by the Automatic Protection Switch Channel MEG level Mainte...

Страница 249: ...ig command usage in this node context 7 6 7 6 status sub node 7 6 7 6 1 command command Name command Description Specify the command to execute on a given ERP instance port Full path erp ring status command Mandatory Parameters ID erp port type Screen Output No Table 7 123 command command information cli erp ring status command Usage COMMAND Specify the command to execute on a given ERP instance p...

Страница 250: ...abase FDB flush is not necessary P0 Slot Port Identifies P0 interface in the system by Slot Port pair Type Identifies P0 interface protection classification RPL Non RPL RPL Neighbor Alarm This alarm signals activity in the P0 interface State P0 Interface state Blocking Flushing P1 Slot Port Identifies P1 interface in the system by Slot Port pair Type Identifies P1 interface protection classificati...

Страница 251: ...s node context Figure 7 152 Output of show command in this node context Parameter Group Parameter Description APS Channel RX P0 RX P1 TX Request State Received APS channel request state message RPL Blocked RPL Blocked State Do Not Flush Do not Flush message Blocked Port Reference Blocked port reference ID Remote Node ID Identification of Remote Node by ID Table 7 127 show command with argument ID ...

Страница 252: ...nfig Description Configure one Protection Group parameters Full path eth protection config Mandatory Parameters ID Screen Output No Table 7 129 config command information cli eth protection config Usage CONFIG Configure ethernet Protection Group parameters MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable h...

Страница 253: ... port Identifies the Protecting Interface ID reversible Specify is reversion is enabled enable disable w port Identifies the Working Interface ID wtr time Wait to Restore Time WTR 5 12 min OPTIONAL auto removal User s auto removal enable disable expire time User s expire time hours Figure 7 156 CLI on line help on create command usage in this node context 7 6 8 4 remove command Name remove Descrip...

Страница 254: ...rotection group Id Admin Ethernet protection group administrative state Mode 1 to 1 Interface Working Slot Identifies the Working slot Port Identifies the Working Interface Interface Protection Slot Identifies the Protecting slot Port Identifies the Protecting Interface Reversible Indicates if reversion is enabled enable disable WTR min Wait to restore 5 12 min Hold Off x100ms Hold Off Time 0 to 1...

Страница 255: ...command usage in this node context Figure 7 162 Output of show command in this node context Parameter Group Parameter Description ID Ethernet protection group Id Interface Working Slot Identifies the Working slot Port Identifies the Working Interface Status Working interface Status information Interface Protection Slot Identifies the Protecting slot Port Identifies the Protecting Interface Status ...

Страница 256: ...ection Group parameters Full path gpon protection config Mandatory Parameters ID Screen Output No Table 7 138 config command information cli gpon protection config Usage CONFIG Configure one Protection Group parameters MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable hold off time Hold Off Time 0 100 x100m...

Страница 257: ...d LOSi on all ONUs connected to this OLT interface enable disable p port Identifies the Protecting Interface ID e g pon 2 reversible Specify is reversion is enabled enable disable w port Identifies the Working Interface ID e g pon 2 wtr time Wait to Restore Time WTR 5 12 min Figure 7 166 CLI on line help on create command usage in this node context 7 6 9 4 remove command Name remove Description Re...

Страница 258: ...Id Admin GPON Type B protection group administrative state Mode 1to 1 Interface Working Slot Identifies the Working slot Port Identifies the Working Interface Interface Protection Slot Identifies the Protecting slot Port Identifies the Protecting Interface Reversible Indicates if reversion is enabled enable disable WTR min Wait to restore 5 12 min Hold Off x100ms Hold Off Time 0 to 100 x100ms Tabl...

Страница 259: ...Protection Group Figure 7 171 CLI on line help on status command usage in this node context Figure 7 172 Output of show command in this node context Parameter Group Parameter Description ID GPON Type B protection group Id Interface Working Slot Identifies the Working slot Port Identifies the Working Interface Status Working interface Status information Interface Protecting Slot Identifies the Prot...

Страница 260: ...wconfig cos config show showconfig dhcp config show showconfig multicast config show showconfig statistics errors show ethernet show gpon show status show SFPs show rx power read all show lag config create remove show showconfig cos config show showconfig mapping attach availableValues detach statistics show status show rf overlay config show showconfig status show Figure 7 173 Interfaces node tre...

Страница 261: ...e mtu Sets the Maximum Transmission Unit which corresponds to the largest packet that can be transmitted 1518 9600 Bytes timeout Set the timeout used by the LACPDUs packets short long 1s 30s Figure 7 174 CLI on line help on config command usage in this node context 7 6 10 1 2 show command Name show Description Show the current configuration Full path interfaces ethernet show Mandatory Parameters N...

Страница 262: ...d list that enforces the current configuration Full path cli interfaces Ethernet showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 149 showconfig command information cli interfaces ethernet showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration...

Страница 263: ...age in this node context 7 6 10 1 4 2 show command This command provides information on all the equipment Ethernet interfaces CoS configuration CoS traffic profile and scheduler policy Name show Description Show the current CoS configuration Full path interfaces ethernet cos show Mandatory Parameters No Screen Output Table Figure 7 180 Table parameter description in Table 7 152 Table 7 151 show co...

Страница 264: ...datory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 153 showconfig command information 7 6 10 1 5 dhcp sub node 7 6 10 1 5 1 config command Name config Description Configure DHCP mode parameter for the given interfaces Full path interfaces ethernet dhcp config Mandatory Parameters port slot Scre...

Страница 265: ...tion Full path interfaces ethernet dhcp showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 156 showconfig command information cli interfaces ethernet dhcp showconfig Usage SHOWCONFIG SHOWCONFIG Print the command list that enforces the current configuration Figure 7 183 CLI on line...

Страница 266: ...ters No Screen Output Table Table 7 158 show command information cli interfaces ethernet multicast show Usage SHOW SHOW Shows ETH multicast information for a specific HW slot Figure 7 185 CLI on line help on show command usage in this node context Parameter Description Slot Slot number Card Name Name of the board inserted in a slot Details YES multicast is configured in the board and detailed info...

Страница 267: ...ct an OLT service by ID upstream eth profile id Choose an existing upstream Ethernet profile by ID OPTIONAL admin Administrative State Enable disable in this context enable disable dhcp op18 DHCP Op 18 flag dhcp op37 DHCP Op 37 flag dhcp op82 DHCP Op 82 flag igmp IGMP enable disable mac limit Specifies the maximum number of MAC addresses allowed for a given client service unlimited or 1 99 max ban...

Страница 268: ...nd in this node context Parameter Description Slot Slot number Card Name Name of the card inserted in the slot Ethernet interfaces Available card ethernet interfaces Table 7 163 availableValues command output table parameters Table Available interfaces for client services Parameter Description ID Network service identifier number Name Network service name Admin Network service administrative statu...

Страница 269: ...p maximum bandwidth in Kbps unlimited or 0 100000000 max groups Set the maximum number of multicast groups unlimited or 0 16384 name Set a name for this Client Service STRING 65 nni ctag Inner VLAN ID client on the network facing Ethernet interface 1 4094 remoteID Remote ID field added to DHCP packets in DHCPop 82 enabled services STRING 63 serviceID Select an OLT service by ID uni ctag VLAN ID de...

Страница 270: ...ut Tables Figure 7 193 Table parameter description in Table 7 168 Table 7 167 show command information cli interfaces ethernet services show Usage SHOW Show the current ethernet Services configuration OPTIONAL serviceID client Choose a client service by ID Figure 7 192 CLI on line help on show command usage in this node context Figure 7 193 Output of show command in this node context Parameter Des...

Страница 271: ...rnet services showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 170 showconfig command information cli interfaces ethernet services showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration Figure 7 195 CLI on line help on showconfig command usage...

Страница 272: ... Service ID number and Service Name Table 7 172 availableValues command output table parameters 7 6 10 1 7 8 1 2 show command Name show Description Show the statistics for a given client service whose counter has already been activated Full path interfaces ethernet services statistics counters show Mandatory Parameters serviceID client Screen Output Table Figure 7 199 Table parameters description ...

Страница 273: ...ink Rx Tx Dropped Number of Dropped packets Uplink Rx Tx Downlink Rx Tx Table 7 174 show command output table parameters 7 6 10 1 7 8 1 3 show active command Name Show active Description Display all active counters Full path interfaces ethernet services statistics counters show active Mandatory Parameters This command has no parameters Screen Output Table Figure 7 201 Table parameters description ...

Страница 274: ...s ethernet services statistics counters start Mandatory Parameters serviceID client Screen Output No Table 7 177 start command information cli interfaces ethernet services statistics counters start Usage START Start the statistics counter for a given client service MANDATORY serviceID client Choose a client service by ID Figure 7 202 CLI on line help on start command usage in this node context 7 6...

Страница 275: ...t Screen Output Table Table 7 179 show command information cli interfaces ethernet services statistics dhcp show Usage SHOW SHOW Show DHCP statistics for a client service with DHCP enabled MANDATORY port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 serviceID client Choose a client service by ID Figure 7 204 CLI on line help on show command usage in this node context 7 6 10 1 7 8 3 igmp...

Страница 276: ...ics sub node 7 6 10 1 8 1 show command Name show Description Show the current ethernet statistics Full path interfaces ethernet statistics show Mandatory Parameters port Screen Output Table Figure 7 207 Table parameters description in Table 7 182 Table 7 181 show command information cli interfaces ethernet statistics show Usage SHOW Show the current ethernet statistics MANDATORY port Identifies an...

Страница 277: ...ets 65 127 Octets Number of packets with size between 65 to 127 bytes Packets 128 255 Octets Number of packets with size between 128 to 255 bytes Packets 256 511 Octets Number of packets with size between 256 to 511 bytes Packets 512 1023 Octets Number of packets with size between 512 to 1023 bytes Packets 1024 Octets Number of packets with size equal to or higher than 1024 bytes Throughput bps In...

Страница 278: ...er Rx dBm Indicates the received optical power in dBm Bias Current mA Indicates the laser BIAS current in mA Temperature ºC Indicates the XFP module temperature in ºC Laser Indicates the Laser operational States ON OFF Table 7 184 show command output table 7 6 10 1 9 2 SFPs sub node 7 6 10 1 9 2 1 show command Name show Description Show details for an SFP entry from table ethernet status show Full...

Страница 279: ... 1 9 3 1 show command Name show Description Show the active channels on a given Client Service Full path interfaces ethernet status active channels show Mandatory Parameters port serviceID client Screen Output Table Figure 7 213 Table parameters description in Table 7 187 Table 7 186 show command information ...

Страница 280: ...0 1 10 vlan sub node 7 6 10 1 10 1 config command Name config Description Configure vlan information for Eth interfaces Full path interfaces ethernet vlan config Mandatory Parameters port Screen Output No Table 7 188 config command information cli interfaces ethernet vlan config Usage CONFIG CONFIG Configure vlan information for Eth interfaces MANDATORY port Identifies an interface on the OLT e g ...

Страница 281: ...node context Parameter Description ID Table entry identifier number Name Ethernet interface identifier Acceptable Frame Types Indicates acceptable frame type Default VLANID Indicates used default VLAN identifier Default Priority Indicates used default Priority Table 7 190 show command output table 7 6 10 1 10 3 showconfig command Name showconfig Description Print the command list that enforces the...

Страница 282: ...enable disable ber Bit Error Rate BER Interval according to G 984 3 Value in seconds 1 3600 s fec downstream Forward Error Correction FEC on the Downstream side enable disable ip source guard Enable Disable IP Source Guard filtering for the specified interface enable disable mac agging Time it takes for a MAC address to be removed from the GPON MAC table Value in seconds 120 3600 s mapping mode Sp...

Страница 283: ... that source address in that GPON port This value must be in the range between 120 and 3600 seconds Note The MAC addresses in the GPON interface are only learnt in Unicast Unstacked Services Max distance Km Maximum distance for which the interface can detect ONU s The difference between the minimum and the maximum can t exceed 20km and the maximum distance can t be higher than 60km Min distance Km...

Страница 284: ... used to manage CoS configuration of PON interfaces in all slots 7 6 10 2 4 1 config command Name config Description Configure CoS information for PON interfaces Full path interfaces gpon cos config Mandatory Parameters cos port Screen Output No Table 7 196 config command information cli interfaces gpon cos config Usage CONFIG Configure CoS information for PON interfaces MANDATORY cos Identifies a...

Страница 285: ...utput of show command in this node context Parameter Description Port PON port identification in the board CoS Class of Service Number 1 8 PCPs p bit associated to the Class of Service 0 8 marked X ID Profile ID number Ethernet Profile Profile Name Scheduler Scheduler policy strict weighted Table 7 198 show command output table parameters 7 6 10 2 4 3 showconfig command Name showconfig Description...

Страница 286: ... dhcp config Usage CONFIG CONFIG Configure DHCP mode parameter for the given interfaces MANDATORY port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 slot Identifies a slot OPTIONAL is trusted Set the DHCP mode default untrusted mode 0 untrusted 1 trusted Figure 7 226 CLI on line help on config command usage in this node context 7 6 10 2 5 2 show command This command used without argumen...

Страница 287: ...show command with argument slot output table parameters 7 6 10 2 5 3 showconfig command Name showconfig Description Prints the command list that enforces the current configuration Full path interfaces gpon dhcp showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 203 showconfig comm...

Страница 288: ... bandwidth Set the multicast group maximum bandwidth in Kbps unlimited or 0 100000000000 max groups Set the maximum number of multicast groups unlimited or 0 16384 Figure 7 230 CLI on line help on config command usage in this node context 7 6 10 2 6 2 show command Name show Description Shows PON multicast information for a specific HW slot Full path interfaces gpon multicast show Mandatory Paramet...

Страница 289: ...ble parameters 7 6 10 2 6 3 showconfig command Name showconfig Description Prints the command list that enforces the current configuration Full path interfaces gpon multicast showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 207 showconfig command information cli interfaces gpon ...

Страница 290: ...r a given Gpon Interface MANDATORY port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 234 CLI on line help on show command usage in this node context Figure 7 235 Output of show command in this node context Parameter Description ONU ID ONU identifier number BIP8 total partial Errors received by the OLT for each of the ONU s upstream direction REI total partial Errors received b...

Страница 291: ...h size less than 64 bytes Oversize Packets Number of packets with size over than 1518 bytes Fragments Number of packets with size less than 64 bytes and with wrong FCS Frame Check Sequence Jabbers Number of packets with size over than 1518 bytes and with wrong FCS Frame Check Sequence Collisions Number of collisions in the Ethernet Segment only in Half Duplex Packets 64 Octets Number of 64 bytes p...

Страница 292: ...s an interface on the OLT e g pon 2 eth 3 lag 1 slot Identifies a slot Figure 7 238 CLI on line help on show command usage in this node context Figure 7 239 Output of show command in this node context Parameter Description Network Packets In this parameter is possible to check the GPON valid error dropped received transmitted packets from to the network PON Packets In this parameter is possible to...

Страница 293: ...in this node context Figure 7 241 Output of show command in this node context Parameter Description Interfaces GPON interface identifier Admin GPON interface administrative state Fixed Kbps Fixed Bandwidth must be less than 1 2Gb s Assured Kbps Assured Bandwidth must be less than 1 2Gb s Maximum Kbps Maximum Bandwidth CBR Kbps CBR Fixed Bandwidth must be less than 480Mb s SFP SFP Module Tx dBm Ind...

Страница 294: ... 7 216 show command information cli interfaces gpon status SFPs show Usage SHOW Show details for an SFP entry from table gpon status show MANDATORY port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 242 CLI on line help on show command usage in this node context This command displays for the SFPs XFPs inserted in the specified port slot the Base ID fields and the Extended ID fi...

Страница 295: ...ge READ ALL Read rx power entries for all ONUs on the selected interface MANDATORY port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 244 CLI on line help on read all command usage in this node context 7 6 10 2 8 3 2 show command This command displays detailed rx power information for an SFP on a GPON interface specified by slot and port arguments In order to have updated value...

Страница 296: ... table parameters 7 6 10 3 lag sub node This node is used to manage the LAG configuration 7 6 10 3 1 config command Name config Description Configure a given LAG interface Full path interfaces lag config Mandatory Parameters lag id Screen Output No Table 7 220 config command information cli interfaces lag config Usage CONFIG Configure a given LAG interface MANDATORY lag id Identifies a LAG by ID 0...

Страница 297: ...iption Remove an existing LAG Full path interfaces lag remove Mandatory Parameters lagID Screen Output No Table 7 222 remove command information cli interfaces lag remove Usage REMOVE Remove an existing LAG MANDATORY lag id Identifies a LAG by ID 0 14 Figure 7 249 CLI on line help on remove command usage in this node context 7 6 10 3 4 show command Name show Description Shows the current LAGs conf...

Страница 298: ...type of traffic Load Balancing of the LAG interface Source MAC Destination MAC Source and Destination MAC Attached Interfaces Slot Name Indicates the Ports that belong to the LAG identified by slot port pair Table 7 224 show command output table parameters 7 6 10 3 5 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path interfaces l...

Страница 299: ... by ID scheduler Identifies the type of Scheduler strict weighted Figure 7 254 CLI on line help on config command usage in this node context 7 6 10 3 6 2 show command This command used without arguments provides information on all the equipment LAG interfaces CoS configuration CoS traffic profile and scheduler policy When used with the argument slot it displays that information only for the specif...

Страница 300: ...output table parameters 7 6 10 3 6 3 Command showconfig Name showconfig Description Print the command list that enforces the current configuration Full path interfaces lag showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 229 showconfig command information cli interfaces lag show...

Страница 301: ...D 0 14 port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 258 CLI on line help on attach command usage in this node context 7 6 10 3 6 4 2 availableValues command Name availableValues Description Display the interfaces that can be used to attach detach Full path interfaces lag mapping availableValues Mandatory Parameters This command has no parameters Screen Output Table Figure...

Страница 302: ...7 233 detach command information cli interfaces lag mapping detach Usage DETACH Remove the specified interface by slot port from the given LAG ID MANDATORY lag id Identifies a LAG by ID 0 14 port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 261 CLI on line help on detach command usage in this node context 7 6 10 3 6 5 statistics sub node 7 6 10 3 6 5 1 show command Name show D...

Страница 303: ...LAG Rx Total Partial Indicates the Total Partial number of LACPDUs received Tx Total Partial Indicates the Total Partial number of LACPDUs transmitted Table 7 235 show command output table parameters 7 6 10 3 6 6 status sub node 7 6 10 3 6 6 1 show command Name show Description Show the status information for the LAG interfaces Full path interfaces lag status show Mandatory Parameters This command...

Страница 304: ...nd s LACPDUs Underlying Interfaces Slot port Indicates the Ports identified by the pair slot port that belong to the LAG Status Indicates if the status of the ports in the LAG Active Inactive Table 7 237 show command output table parameters 7 6 11 ip node cli ip tree ip apply save interfaces inband config show showconfig ip config show showconfig networking config show showconfig route create remo...

Страница 305: ...ion to the system startup configuration Figure 7 268 CLI on line help on save command usage in this node context 7 6 11 3 interfaces sub node 7 6 11 3 1 inband sub node 7 6 11 3 1 1 config command Name config Description Configure an Inband interface Full path ip interfaces inband config Mandatory Parameters port set InBand Screen Output No Table 7 240 config command information cli ip interfaces ...

Страница 306: ...rrent configuration Figure 7 270 CLI on line help on show command usage in this node context Figure 7 271 Output of show command in this node context Parameter Description Slot Slot number of the uplink interface not applicable for LAG Port Interface or LAG Inband Indicates if the interface is used or not to manage the system YES if in use Table 7 242 show command output table parameters 7 6 11 3 ...

Страница 307: ...ure MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable ip address IPv4 address mask bits IPv4 Subnet Mask bits 0 32 vlan Choose a VLAN ID Figure 7 274 CLI on line help on config command usage in this node context 7 6 11 3 2 2 show command This command displays general information on the system configuration ...

Страница 308: ...dentifier used in the inBand interface Table 7 245 show command output table parameters 7 6 11 3 2 3 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path ip interfaces ip showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration ...

Страница 309: ...in this node context 7 6 11 4 2 show command This command displays general information on the system configuration indicating the interfaces available in the system for Inband configuration and showing current InBand configuration Name show Description Show the current configuration Full path ip networking show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 280 Ta...

Страница 310: ...NFIG Print the command list that enforces the current configuration Figure 7 281 CLI on line help on showconfig command usage in this node context 7 6 11 5 route sub node This sub node allows the creation and configure of an IP route to reach the manager entity if necessary 7 6 11 5 1 create command This command creates an IP route There can only be one IP route Name create Description Creates an ...

Страница 311: ... 6 11 5 3 show command This command displays general information on the system configuration indicating the interfaces available in the system for Inband configuration and showing current InBand configuration Name show Description Show the current configuration Full path ip route show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 285 Table parameters description ...

Страница 312: ...utput Full command s path and used arguments and values to reach the current configuration Table 7 255 showconfig command information cli ip networking showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration Figure 7 286 CLI on line help on showconfig command usage in this node context 7 6 12 ip source guard node cli ip source guard tree ip source guard config cr...

Страница 313: ...tory Parameters No Screen Output No Table 7 257 create command information cli ip source guard create Usage CREATE CREATE Create a new IP Source Guard entry OPTIONAL ID Identifies a table entry by ID in this context admin Administrative State Enable disable in this context enable disable ip address IPv4 IPv6 address mac Identify Set a MAC entry in this context port Identifies an interface on the O...

Страница 314: ...tion in Table 7 260 Table 7 259 show command information cli ip source guard show Usage SHOW SHOW Show the current configuration OPTIONAL ID Identifies a table entry by ID in this context Figure 7 291 CLI on line help on show command usage in this node context Figure 7 292 Output of show command in this node context Parameter Description ID Table entry Identifier number Admin IPsource Guard Filter...

Страница 315: ...rent configuration Figure 7 293 CLI on line help on showconfig command usage in this node context 7 6 13 logs node This node is used to view logs for all the system events cli logs tree logs alarms clear show Figure 7 294 Logs node tree 7 6 13 1 alarms sub node 7 6 13 1 1 clear command Name clear Description Clear all alarms for a given slot or all alarms for all slots Full path ip logs alarms cle...

Страница 316: ...how Usage SHOW Show registered alarms Global or slot specific Figure 7 296 CLI on line help on show command usage in this node context Figure 7 297 Output of show command used with no argument in this node context Global alarm list Figure 7 298 Partial view of show command with argument slot output in this node context Parameter Description Table Title Alarms List Page page number if more than one...

Страница 317: ... Define the MAC aging time in seconds 10 1000000 Figure 7 300 CLI on line help on config command usage in this node context 7 6 14 2 show command This command displays the Aging Time which defines the maximum time each MAC address can be at the MAC table when no packet with that MAC address arrives to the system Name show Description Show the current configuration Full path mac table show Mandator...

Страница 318: ...7 6 14 3 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path mac aging showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 268 showconfig command information cli ip networking showconfig Usage SHOWCONFIG Print the ...

Страница 319: ...rt the value from column Port from the show table e g pon 2 eth 3 lag 1 SF serviceID Select an OLT service by ID Figure 7 304 CLI on line help on remove command usage in this node context 7 6 14 4 1 2 show command Name Show Description Show the GPON MAC Table Full path mac table status gpon show Mandatory Parameters No Screen Output Table Figure 7 306 Table parameters description in Table 7 271 Ta...

Страница 320: ... Remove one Switch MAC entry from the Table All parameters are mandatory except when shown Full path mac table status switch remove Mandatory Parameters mac Screen Output No Table 7 272 remove command information cli mac table status switch remove Usage REMOVE REMOVE Remove one Switch MAC entry from the Table All parameters are mandatory except when shown MANDATORY mac Identify Set a MAC entry in ...

Страница 321: ... fabric slot OPTIONAL mac Identify Set a MAC entry in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 serviceID Select an OLT service by ID vlan Choose a VLAN ID Figure 7 308 CLI on line help on show command usage in this node context Figure 7 309 Output of show command in this node context Parameter Description Slot Indicates the Slot Port Indicates the Port ONT ID Indi...

Страница 322: ...hows the users list for the selected channel Full path multicast active groups status Mandatory Parameters No Screen Output Table Figure 7 312 Table parameter description Table 7 276 Table 7 275 status command information cli multicast active groups status Usage STATUS With no arguments shows the active channels list With both arguments shows the users list for the selected channel OPTIONAL ip add...

Страница 323: ...entifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable bandwidth Specify the multicast group bandwidth in units of Kbps group mask Group IPv4 address mask 0 22 32 ip address IPv4 address name Set a name for the specified multicast group STRING 31 serviceID Select an OLT service by ID src ipv4 addr Specify the source IPv4 addre...

Страница 324: ...gure 7 314 CLI on line help on create command usage in this node context 7 6 15 2 3 remove command Name remove Description Remove an existing multicast group Full path multicast group list remove Mandatory Parameters ID Screen Output No Table 7 279 remove command information cli multicast group list remove Usage REMOVE Remove an existing multicast group MANDATORY ID Identifies a table entry by ID ...

Страница 325: ...oup Mask Indicates the group mask Src IP address Indicates IPv4 source address Bandwidth Kbps Indicates Group Bandwidth Table 7 281 show command output table parameters 7 6 15 2 5 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path multicast group list showconfig Mandatory Parameters This command has no parameters Screen Output Fu...

Страница 326: ...he multicast group endpoint uni nni group limit ctrl Enable or disable group limit control enable disable Figure 7 319 CLI on line help on config command usage in this node context 7 6 15 3 1 2 show command Name show Description Show the current configuration Full path multicast igmp global show Mandatory Parameters This command has no parameters Screen Output Tables Figure 7 321 Table parameters ...

Страница 327: ...l showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 286 showconfig command information cli multicast igmp global showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration Figure 7 322 CLI on line help on showconfig command usage in this node conte...

Страница 328: ... be adjusted for the expected packet loss on the network 1 7 unsolicited report interval Time interval between repetitions of a host s initial group membership report 1 10 Figure 7 323 CLI on line help on config command usage in this node context 7 6 15 3 2 2 show command Name show Description Show the current configuration Full path multicast igmp proxy show Mandatory Parameters This command has ...

Страница 329: ...le parameters 7 6 15 3 2 3 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path multicast igmp proxy showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 290 showconfig command information cli multicast igmp proxy sh...

Страница 330: ...Queries 1 31744 startup query count Number of retransmissions of general queries sent on startup startup query interval Interval between retransmissions of general queries sent on startup Figure 7 327 CLI on line help on config command usage in this node context 7 6 15 3 3 2 show command Name show Description Show the current configuration Full path multicast igmp querier show Mandatory Parameters...

Страница 331: ...ted packet loss on the network Last Member Querier Interval Max Response Time used to calculate the Max Resp Code inserted into Group Specific queries sent in response to Leave Group messages Last Member Querier Count Number of Group Specific Queries sent before the router assumes there are no local members Table 7 293 show command output table parameters 7 6 15 3 3 3 showconfig command Name showc...

Страница 332: ...ticast probes config Usage CONFIG Modify parameters for an existing probe MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable ip mcast IPv4 multicast address port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 serviceID Select an OLT service by ID Figure 7 331 CLI on line help on config command usag...

Страница 333: ...atory Parameters ID Screen Output No Table 7 297 remove command information cli multicast probes remove Usage REMOVE Remove an existing Probe MANDATORY ID Identifies a table entry by ID in this context Figure 7 333 CLI on line help on remove command usage in this node context 7 6 15 4 4 show command Name show Description Show the current multicast probes configuration Full path multicast probes sh...

Страница 334: ...es the current configuration Full path multicast probes showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 300 showconfig command information cli multicast probes showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration Figure 7 336 CLI on line he...

Страница 335: ... Unicast Number of Unicast packets Multicast Number of Multicast packets Broadcast Number of Broadcast packets Dropped Number of Dropped packets Table 7 302 show command output table parameters 7 6 16 profiles node cli profiles tree profiles dscp to pbits config create remove show showconfig ethernet config create remove show showconfig onu config create remove show showconfig pbits to pq config c...

Страница 336: ...pecified profile p bits Define the P bits value 0 7 Figure 7 340 CLI on line help on config command usage in this node context 7 6 16 1 2 create command Name create Description Create a new profile that assigns DSCP to P bits Full path profiles dscp to pbits create Mandatory Parameters No Screen Output No Table 7 304 create command parameters cli profiles dscp to pbits create Usage CREATE CREATE C...

Страница 337: ...n this node context 7 6 16 1 4 show command Name show Description Show existing profiles Full path profiles dscp to pbits show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 344 and Figure 7 345 Tables parameters description Table 7 307 and Table 7 308 Table 7 306 show command information cli profiles dscp to pbits show Usage SHOW SHOW Show existing profiles OPTIO...

Страница 338: ...Table 7 308 show command with argument ID output table parameters 7 6 16 1 5 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path profiles dscp to pbits showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 309 showco...

Страница 339: ... ID OPTIONAL admin Administrative State Enable disable in this context enable disable cbs Committed Burst Size maximum number of bytes in a burst of packets that should be guaranteed 0 262144 bytes cir Committed Information Rate bandwidth that should be guaranteed on average 0 1000000000 bit s ebs Excess Burst Size maximum number of bytes in a burst of packets if there is no traffic congestion 0 I...

Страница 340: ...mation cli profiles ethernet remove Usage REMOVE Remove an Ethernet traffic profile MANDATORY profileID Identifies a profile by ID Figure 7 349 CLI on line help on remove command usage in this node context 7 6 16 2 4 show command Name show Description Show the current configured multicast groups Full path profiles ethernet show Mandatory Parameters This command has no parameters Screen Output Tabl...

Страница 341: ... command output table parameters 7 6 16 2 5 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path profiles ethernet showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 315 showconfig command information cli profiles ...

Страница 342: ... a profile by ID OPTIONAL admin Administrative State Enable disable in this context enable disable model Define the Model Name STRING 47 name Define a name for this profile STRING 47 port num The number of ports for a given port type max 4 ETH 1 PON 1 RF 2 VoIP 4 E1 1 VEIP port type The type of a port eth pon voip rf e1 veip vendor Define the Vendor Name STRING 15 Figure 7 353 CLI on line help on ...

Страница 343: ...3 remove command Name remove Description Remove an ONU profile Full path profiles onu remove Mandatory Parameters profileID Screen Output No Table 7 318 remove command parameters cli profiles onu remove Usage REMOVE Remove MANDATORY profileID Identifies a profile by ID Figure 7 355 CLI on line help on remove command usage in this node context 7 6 16 3 4 show command Name show Description Show the ...

Страница 344: ...owconfig Description Print the command list that enforces the current configuration Full path profiles ethernet showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 321 showconfig command information cli profiles onu showconfig Usage SHOWCONFIG Print the command list that enforces t...

Страница 345: ...eate a new profile that assigns P bits to Priority Queues Full path profiles pbits to pq create Mandatory Parameters No Screen Output No Table 7 323 create command parameters cli profiles pbits to pq create Usage CREATE CREATE Create a new profile that assigns P bits to Priority Queues OPTIONAL ID Identifies a table entry by ID in this context admin Administrative State Enable disable in this cont...

Страница 346: ...ory Parameters This command has no parameters Screen Output Table Figure 7 363 Table parameters description Table 7 326 Table 7 325 show command information cli profiles pbits to pq show Usage SHOW SHOW Show existing profiles Figure 7 362 CLI on line help on show command usage in this node context Figure 7 363 Output of show command in this node context Parameter Description ID Indicates the Profi...

Страница 347: ...ig Mandatory Parameters profileID Screen Output No Table 7 328 config Command parameters cli profiles upstream dba config Usage CONFIG CONFIG Configure GPON upstream DBA profiles MANDATORY profileID Identifies a profile by ID OPTIONAL BWeligibility Defines how the non assured bandwidth is handled non assured best effort admin Administrative State Enable disable in this context enable disable assur...

Страница 348: ...te Enable disable in this context enable disable assuredBW Maximum bandwidth for DYN type with a granularity of 8kbps dba Set the MAC GPON DBA algorithm to Status Reporting if enabled or Traffic Monitoring if disabled enable disable maxBW Maximum bandwidth that results from the sum Fixed BW Assured BW bandwidth not assured profileID Identifies a profile by ID Figure 7 366 CLI on line help on creat...

Страница 349: ...ies upstream profile by name Admin Indicates upstream profile administrative state Type Indicates upstream profile type Fixed BW indicates upstream profile fixed bandwidth Assured BW Indicates upstream profile assured bandwidth Max BW Indicates upstream profile maximum bandwidth BW eligibility Indicates upstream profile bandwidth eligibility DBA algorithm Indicates if DBA algorithm is used Table 7...

Страница 350: ... command Name availableValues Description Show Available Values for each parameter Full path profiles voip server availableValues Mandatory Parameters This command has no parameters Screen Output Table Figure 7 372 Table parameters description Table 7 335 Table 7 334 availableValues command information cli profiles voip server availableValues Usage AVAILABLEVALUES Show Available Values for each pa...

Страница 351: ...erver config Usage CONFIG Configure MANDATORY profileID Identifies a profile by ID OPTIONAL admin Administrative State Enable disable in this context enable disable gw ip IPv4 address for the default GW name Insert a name STRING server ip IPv4 address for the VoIP server server port The VoIP server port voice gw The Voice Gateway to choose see availableValues 1 5 Figure 7 373 CLI on line help on c...

Страница 352: ... server profile Full path profiles voip server remove Mandatory Parameters profileID Screen Output No Table 7 338 remove command information cli profiles voip server remove Usage REMOVE Remove an existing profile MANDATORY profileID Identifies a profile by ID Figure 7 375 CLI on line help on remove command usage in this node context 7 6 16 6 1 5 show command Name show Description Show the current ...

Страница 353: ...n Print the command list that enforces the current configuration Full path profiles voip server showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 341 showconfig command information cli profiles voip server showconfig Usage SHOWCONFIG Print the command list that enforces the curre...

Страница 354: ...specific profile Full path profiles voip specific create Mandatory Parameters No Screen Output No Table 7 343 create command information cli profiles voip specific create Usage CREATE CREATE Create a new VoIP specific profile OPTIONAL admin Administrative State Enable disable in this context enable disable ftp ip Set the FTP server IP address name Define a name for this profile STRING 15 Figure 7 ...

Страница 355: ...e 7 346 Table 7 345 show command information cli profiles voip specific show Usage SHOW Show the current configuration Figure 7 382 CLI on line help on show command usage in this node context Figure 7 383 Output of show command in this node context Parameter Description ID Identifies a profile by ID Name Identifies a profile by name Admin Indicates profile administrative state FTP Server Indicates...

Страница 356: ...ation On the status sub node the user can view the status of links and interfaces cli remote eq tree remote eq config onu id connect disconnect showconnected discovery change reg type command config create insert insert all reboot reboot all remove remove all show showconfig onu show showconfig analog rf config show showconfig e1 config e1 config lsp config pw show showconfig status ethernet confi...

Страница 357: ...lp on config onu id command usage in this node context 7 6 17 2 connect command This command defines the remote Equipment that will be used for all following commands Name connect Description Set the ONU identifiers slot port onuID to be used in all future commands Full path remote eq connect Mandatory Parameters onuID port Screen Output No Table 7 349 connect command information cli remote eq con...

Страница 358: ...Description Clear the connected ONU identifiers Full path remote eq showconnected Mandatory Parameters This command has no parameters Screen Output Table Figure 7 390 Table parameters description in Table 7 352 Table 7 351 showconnected command information cli remote eq showconnected Usage SHOWCONNECTED Show the connected ONU identifiers Figure 7 389 CLI on line help on showconnected command usage...

Страница 359: ... registration Up to 10 ASCII characters or precisely 20 in HEX format STRING 20 serial number Set the serial number for ONU registration STRING 16 Figure 7 391 CLI on line help on change reg type command usage in this node context 7 6 17 5 2 command command Name command Description Send one command to a specific ONU Full path remote eq discovery command Mandatory Parameters type Screen Output No T...

Страница 360: ...nable disable omci encryption Encryption on the OMCI channel enable disable onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 profileID Identifies a profile by ID sw upgrade mode Set the upgrade mode for this ONU By choosing planned the argument sw version must be given as well off auto planned sw version Define a string to match with a fir...

Страница 361: ...ine help on create command usage in this node context 7 6 17 5 5 insert command Name insert Description Start managing a remote ONU It must be in the new state Full path remote eq discovery insert Mandatory Parameters profileID serial number Screen Output No Table 7 357 insert command information cli remote eq discovery insert Usage INSERT INSERT Start managing one remote ONU ONUs must be in the N...

Страница 362: ...es will be used for all parameters OPTIONAL port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 396 CLI on line help on insert all command usage in this node context 7 6 17 5 7 reboot command Name reboot Description Send the reboot command to one ONU Full path remote eq discovery reboot Mandatory Parameters No Screen Output No Table 7 359 reboot command information cli remote eq...

Страница 363: ...t will return to the NEW state if physically connected Full path remote eq discovery remove Mandatory Parameters No Screen Output No Table 7 361 remove command information cli remote eq discovery remove Usage REMOVE REMOVE Stop managing one remote ONU It will return to the NEW state if physically connected OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the O...

Страница 364: ...Usage SHOW SHOW Show a list with all ONUs known Filters can be applied with the arguments below OPTIONAL matching serial number Show ONU matching the serial number specified STRING 16 only new Show only entries with state equal to new true false password format Choose the display format for the Password column ascii string hex string default hex string port Identifies an interface on the OLT e g p...

Страница 365: ...G Print the command list that enforces the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 403 CLI on line help on showconfig command usage in this node context 7 6 17 6 ONUs sub node This node can be used to configure the remote ONU equipments All the commands in this node and children always apply...

Страница 366: ...Screen Output Table Figure 7 405 Table parameters description in Table 7 367 Table 7 366 show command information cli remote eq onu show Usage SHOW Display a table with all ONU IDs and their respective interfaces Can filter the results with the optional arguments OPTIONAL port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 404 CLI on line help on show command usage in this node ...

Страница 367: ...e eq onu analog rf config Mandatory Parameters No Screen Output No Table 7 369 config command information cli remote eq onu analog rf config Usage CONFIG Configure Analog RF parameters for a single ONU OPTIONAL admin Administrative State Enable disable in this context enable disable filter Choose how many channels to filter all 15 25 35 onuID Identifies an ONU by ID in this context port Identifies...

Страница 368: ...lp on show command usage in this node context Figure 7 410 Output of show command in this node context Parameter Description ID Identifies analog RF interface by ID Port Identifies analog RF interface by name Admin Indicates analog RF interface administrative state Filter Indicates type of channel filter used how many filtered channels Table 7 371 show command output table parameters 7 6 17 6 3 3 ...

Страница 369: ...ig e1 Usage CONFIG E1 CONFIG E1 Configure E1 interfaces for a given ONU MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable jitter E1 timing configuration dcr re timing acr loop E1 loop configuration no loop local remote monitor E1 Frame none g 704 g 704 g 706 onuID Identifies an ONU by ID in this context por...

Страница 370: ... 375 config pw command information cli remote eq onu e1 config pw Usage CONFIG PW Configure Pseudowire Ig Eg parameters for a given ONU E1 interface MANDATORY ID Identifies a table entry by ID in this context OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 pw egress Egress pseudowire label 16 1048575 pw ingress Ingress pseudowire...

Страница 371: ... 5 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path remote eq onu e1 showconfig Mandatory Parameters No Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 377 showconfig command information cli remote eq onu e1 showconfig Usage SHOWCONFIG Print the command list that enforc...

Страница 372: ...a given ONU Full path remote eq onu e1 status Mandatory Parameters No Screen Output Table Table 7 378 status command information cli remote eq onu e1 status Usage STATUS Show all the current E1 interfaces status for a given ONU OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 418 CLI on line help on status command usage i...

Страница 373: ...path remote eq onu ethernet show Mandatory Parameters No Screen Output Table Figure 7 421 Table parameters description in Table 7 381 Table 7 380 show command information cli remote eq onu ethernet show Usage SHOW Show the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 420 CLI on line help on show ...

Страница 374: ...es to reach the current configuration Table 7 382 showconfig command information cli remote eq onu ethernet showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 422 CLI on line help on showconfig command usage in this node contex 7 6 17...

Страница 375: ...HEX format port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 423 CLI on line help on config command usage in this node context 7 6 17 6 6 2 show command Name show Description Show Extended VLAN Tagging Operation information on this ONU Full path remote eq onu ext vlan tag op show Mandatory Parameters No Screen Output Table Figure 7 424 Table parameters description in Table 7 3...

Страница 376: ...No Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 386 showconfig command information cli remote eq onu ext vlan tag op showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 426 ...

Страница 377: ... dei any input dei 0 input dei 1 f inner vid Filter by Inner VID onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 serviceID onu Choose a ONU service by ID t op vid Treatment VID Operation add replace discard t priority Treatment Priority 0 7 copy derive from dscp t tpid Treatment TPID 0x8100 Figure 7 427 CLI on line help on config command ...

Страница 378: ...atment VID Operation add replace discard t priority Treatment Priority 0 7 copy derive from dscp t tpid Treatment TPID 0x8100 Figure 7 428 CLI on line help on create command usage in this node context 7 6 17 6 6 4 3 remove command Name remove Description Remove an Extended VLAN Tagging Operation Table entry Full path remote eq onu ext vlan tag op operation table remove Mandatory Parameters ID onu ...

Страница 379: ...rameter Description ONU Port ONU Port Identifier ID Table entry numeric Identifier Admin Indicates upstream profile administrative state T Filter Inner Pri VID Indicates Priotity VID Inner TPID Indicates Inner TPID Ethertype Indicates ETHERTYPE Treatment Operation Indicates Operation ID Service Indicates service by ID number and Name Identifier Priority Indicates Priority TPID Indicates TPID Table...

Страница 380: ...t Full path remote eq onu ptp source availableValues Mandatory Parameters No Screen Output Command not implemented Table 7 393 availableValues command information cli remote eq onu ptp source availableValues Usage AVAILABLEVALUES Show the available values for argument add onu port OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 F...

Страница 381: ...a new PTP source instance on a given ONU and associate it with an existing OLT PTP port Full path remote eq onu ptp source create Mandatory Parameters olt ptp port ID Screen Output No Table 7 395 create command information cli remote eq onu ptp source create Usage CREATE Create a new PTP source instance on a given ONU and associate it with an existing OLT PTP port MANDATORY olt ptp port ID Identif...

Страница 382: ...ontext 7 6 17 6 7 5 show command Name show Description Show PTP source instances on this ONU Full path remote eq onu ptp source show Mandatory Parameters This command has no parameters Screen Output Command not implemented Table 7 397 show command information cli remote eq onu ptp source show Usage SHOW Show PTP source instances on this ONU Figure 7 437 CLI on line help on show command usage in th...

Страница 383: ...veVlan All traffic through the client port will be untagged upstream and downstream enable disable nni ctag Inner VLAN ID client on the network facing Ethernet interface 1 4094 onuID Identifies an ONU by ID in this context pbits to pq profile id Specify an existing P bits to Priority Queue Profile port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 remoteID Remote ID field added to DHCP ...

Страница 384: ...vailableValues command usage in this node context Figure 7 440 availableValues command in this node context Parameter Description Remote ONU Interface List Lists the available interfaces on the Remote ONU Table 7 400 availableValues command output table parameters 7 6 17 6 8 3 config command Name config Description Configure activate an existing service on this ONU Full path remote eq onu services...

Страница 385: ... the maximum number of multicast groups unlimited or 0 16384 name Define a name for the ONU Client Service STRING 65 nativeVlan All traffic through the client port will be untagged upstream and downstream enable disable nni ctag Inner VLAN ID client on the network facing Ethernet interface 1 4094 onuID Identifies an ONU by ID in this context pbits to pq profile id Specify an existing P bits to Pri...

Страница 386: ...ll information for that service Full path remote eq onu services show Mandatory Parameters No Screen Output Tables Figure 7 444 and Figure 7 445 Tables parameters description in Table 7 404 andTable 7 405 Table 7 403 show command information cli remote eq onu services show Usage SHOW Show Services information on this ONU Give a service ID to see the full information for that service OPTIONAL onuID...

Страница 387: ...gmt Indicates if IP management is enabled Table 7 404 show command output table parameters Parameter Description ID Identifies a table entry Service by ID Admin Indicates ONU service administrative state ONU Service Name Identifies ONU service by name ID OLT Service Name Identifies an OLT service by ID and Name Upstream DBA Profile Indicates the upstream profile associated to the service by ID and...

Страница 388: ...s an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 t cont id Specify an existing T CONT 0 for none Figure 7 446 CLI on line help on config command usage in this node context 7 6 17 6 8 6 2 show command Name show Description Show T CONT information on this ONU Full path remote eq onu services t cont mapping show Mandatory Parameters No Screen Output Tables ...

Страница 389: ...tput Full command s path and used arguments and values to reach the current configuration Table 7 409 showconfig command information cli remote eq onu services t cont mapping showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 449 CLI ...

Страница 390: ...g command usage in this node context 7 6 17 6 9 2 show command Name show Description Show the current configuration Full path remote eq onu system show Mandatory Parameters No Screen Output Table Figure 7 452 Table parameters description in Table 7 412 Table 7 411 show command information cli remote eq onu system show Usage SHOW Show the current configuration OPTIONAL onuID Identifies an ONU by ID...

Страница 391: ...on Print the command list that enforces the current configuration Full path remote eq onu system showconfig Mandatory Parameters No Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 413 showconfig command information cli remote eq onu system showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration OPTIONAL o...

Страница 392: ...d usage in this node context 7 6 17 6 10 2 create command Name create Description Add a T CONT to a specific ONU Full path remote eq onu t cont create Mandatory Parameters No Screen Output No Table 7 415 create command information cli remote eq onu t cont create Usage CREATE Add a T CONT to a specific ONU OPTIONAL ID Identifies a table entry by ID in this context admin Administrative State Enable ...

Страница 393: ...ag 1 Figure 7 456 CLI on line help on remove command usage in this node context 7 6 17 6 10 4 show command Name show Description Show T CONT information on this ONU Full path remote eq onu t cont show Mandatory Parameters No Screen Output Table Figure 7 458 Table parameters description in Table 7 418 Table 7 417 show command information cli remote eq onu t cont show Usage SHOW Show T CONT informat...

Страница 394: ... arguments and values to reach the current configuration Table 7 419 showconfig command information cli remote eq onu t cont showconfig Usage SHOWCONFIG Print the command list that enforces the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 459 CLI on line help on showconfig command usage in this n...

Страница 395: ...on e g supported codecs number etc rx gain Specifies the receiver gain dB 12 6 specific profile Identifies a VoIP specific profile by ID manage profiles in profiles voip specific profiles node termination id Used for MEGACO H 248 to identify the line termination tx gain Specifies the transmitter gain dB 12 6 voip profile Identifies a VoIP profile by ID manage profiles in profiles voip node Figure ...

Страница 396: ...utput table parameters 7 6 17 6 11 3 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path remote eq onu voip showconfig Mandatory Parameters No Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 423 showconfig command information cli remote eq onu voip showconfig Usage SHOWCON...

Страница 397: ...s an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 464 CLI on line help on show command usage in this node context 7 6 17 8 status sub node 7 6 17 8 1 show command This command displays status information on all the parameters for the specified ONU Ethernet Status Table Analog RF Status Table GPON Status Table Service Status Table Firmware Status Table Name show Description Show status infor...

Страница 398: ...this node context Parameter Description Remote Port Indicates the Ethernet port at the ONU Admin Indicates the Administrative state Type Indicates the link speed and duplex Link Indicates the physical port state Table 7 426 show command output table parameters Ethernet Status table Parameter Description Port Indicates the ONU Analog RF port Admin Indicates the administrative state State Indicates ...

Страница 399: ...ameter Description Image 0 1 Indicates the Image name Active Indicates which of the images is active Committed Indicates which of the images is active after a reboot Valid Indicates if the SW FW version is Valid Version Indicates the SW FW version name Table 7 430 show command output tables parameters Firmware Status table Parameter Description Maintenance Indicates if ONU is in maintenace Alarms ...

Страница 400: ...Packets CRC Align Errors Number of packets with wrong FCS Frame Check Sequence Undersize Packets Number of packets with size less than 64 bytes Oversize Packets Number of packets with size over than 1518 bytes Fragments Number of packets with size less than 64 bytes and with wrong FCS Frame Check Sequence Jabbers Number of packets with size over than 1518 bytes and with wrong FCS Frame Check Seque...

Страница 401: ...dentify an image by ID 0 1 OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 469 CLI on line help on activate command usage in this node context 7 6 17 8 3 2 commit command Name commit Description Indicates which of the images is used after the next reboot Full path remote eq status firmware commit Mandatory Parameters ima...

Страница 402: ...ransfer command usage in this node context 7 6 17 8 4 gem port sub node 7 6 17 8 4 1 statistics sub node 7 6 17 8 4 1 1 show command Name show Description Show the GEM packet statistics for a given ONU Full path remote eq status gem port statistics show Mandatory Parameters remote port Screen Output Table Figure 7 473 Table parameters description in Table 7 438 Table 7 437 show command information...

Страница 403: ...ion Show the current configuration Full path remote eq status services show Mandatory Parameters No Screen Output Tables Figure 7 475 Table parameter description in Table 7 440 Table 7 439 show command information cli remote eq status services show Usage SHOW Show the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth ...

Страница 404: ... remote eq status services active channels show Usage SHOW Show the active channels on a given ONU MANDATORY serviceID onu Choose a ONU service by ID OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 476 CLI on line help on show command usage in this node context Figure 7 477 Output of show command in this node context Par...

Страница 405: ... ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 478 CLI on line help on availableValues command usage in this node context Figure 7 479 Output of availableValues command in this node context Parameter Description ONU Service ID Name Available ONU Service identified by Service ID number and Service Name Table 7 444 availableValues command output tab...

Страница 406: ...LAG Interface OLT PON Interface Rx Tx OLT Eth LAG or PON Interface as applicable for the selected Service Rx Tx counter values for the applicable interface Total Total number of packets Unicast Total number of Unicast packets Multicast Total number of Multicast packets Broadcast Total number of Broadcast packets Dropped Total number of Dropped packets Table 7 446 show command output table paramete...

Страница 407: ...ng service statistics Table 7 448 show active command output table parameters 7 6 17 8 5 3 1 4 start command Name start Description Activate one statistics counter on the given ONU service Full path remote eq status services statistics counters start Mandatory Parameters serviceID onu Screen Output No Table 7 449 start command information cli remote eq status services statistics counters start Usa...

Страница 408: ...usage in this node context 7 6 17 8 5 3 2 dhcp sub node 7 6 17 8 5 3 2 1 show command Name show Description Show the DHCP statistics for a given unicast service that has DHCPop82 enabled Full path remote eq status services statistics dhcp show Mandatory Parameters serviceID onu Screen Output Table Figure 7 487 Table parameters description in Table 7 452 Table 7 451 show command information cli rem...

Страница 409: ...nterfaces Network side Client Pack with Opts Untrusted Number of dropped packets because they are client requests with options received in Untrusted interfaces Client side Server Packets Untrusted Number of dropped packets because they are server replies with options received in Untrusted interfaces Client Side Server Pack without Options Trusted Number of dropped packets because they are server r...

Страница 410: ...cates the number of transmitted and received packets Total sum of all packets Dropped sum of all dropped packets Valid sum of all valid compliant with the IGMP standards packets Invalid sum of all invalid non compliant with the IGMP standards packets V2 Total and Partial counters Indicates the number of transmitted and received IGMPv2 packets of type Join Invalid Join Leave V3 Total and Partial co...

Страница 411: ...rs description in Table 7 456 Table 7 455 show command information cli remote eq status t cont show Usage SHOW Show the current configuration OPTIONAL onuID Identifies an ONU by ID in this context port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 490 CLI on line help on show command usage in this node context Figure 7 491 Output of show command in this node context Parameter D...

Страница 412: ...ddress Screen Output No Table 7 457 remove command information cli routing arp table remove Usage REMOVE REMOVE Remove an existing ARP entry MANDATORY ip address IPv4 address Figure 7 493 CLI on line help on remove command usage in this node context 7 6 18 1 2 status command Name status Description Display existing problems with the file repository Full path routing arp table status Mandatory Para...

Страница 413: ... path routing ipv4 interface config Mandatory Parameters ID Screen Output No Table 7 460 config command information cli routing ipv4 interface config Usage CONFIG CONFIG Configure MANDATORY ID Identifies a table entry by ID in this context OPTIONAL admin Administrative State Enable disable in this context enable disable ip address IPv4 address mtu Interface MTU 68 9198 name IP interface name STRIN...

Страница 414: ... Parameters ID Screen Output No Table 7 462 remove command information cli routing ipv4 interface remove Usage REMOVE REMOVE Remove an existing entity by ID MANDATORY ID Identifies a table entry by ID in this context Figure 7 498 CLI on line help on remove command usage in this node context 7 6 18 2 4 show command Name show Description Show the current configuration Full path routing ipv4 interfac...

Страница 415: ...list that enforces the current configuration Full path routing ipv4 interface showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 465 showconfig command information cli routing ipv4 interface showconfig Usage SHOWCONFIG SHOWCONFIG Print the command list that enforces the current co...

Страница 416: ...ommand information cli routing ping remove Usage REMOVE REMOVE Remove an existing ping session MANDATORY ID Identifies a table entry by ID in this context Figure 7 503 CLI on line help on remove command usage in this node context 7 6 18 3 3 show command Name show Description Show the current ping sessions configuration Full path routing ping show Mandatory Parameters No mandatory parameters Screen...

Страница 417: ...rguments and values to reach the current configuration Table 7 470 showconfig command information cli routing ping showconfig Usage SHOWCONFIG SHOWCONFIG Print the command list that enforces the current configuration Figure 7 506 CLI on line help on showconfig command usage in this node context 7 6 18 3 5 status command Name status Description Show the current ping sessions status Full path routin...

Страница 418: ... 7 6 18 4 route table sub node 7 6 18 4 1 config command Name config Description Configure an existing static route by ID Full path routing route table config Mandatory Parameters ID Screen Output No Table 7 473 config command information cli routing route table config Usage CONFIG CONFIG Configure an existing static route by ID MANDATORY ID Identifies a table entry by ID in this context OPTIONAL ...

Страница 419: ...line help on create command usage in this node context 7 6 18 4 3 remove command Name remove Description Remove an existing static route by ID Full path routing route table remove Mandatory Parameters ID Screen Output No Table 7 475 remove command information cli routing route table remove Usage REMOVE REMOVE Remove an existing static route by ID MANDATORY ID Identifies a table entry by ID in this...

Страница 420: ... 7 6 18 4 5 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path routing route table showconfig Mandatory Parameters This command has no parameters Screen Output Full command s path and used arguments and values to reach the current configuration Table 7 478 showconfig command information cli routing route table showconfig Usage SH...

Страница 421: ...ifier Update time Route update time Destination IP Address Route Destination IP Address Destination IP Mask Route Destination IP Mask Gateway IP Addr Route used Gateway IP Address Preference Route Preference Metric Route Metric number of hops Table 7 480 status command output table parameters 7 6 18 5 traceroute sub node 7 6 18 5 1 create command Name create Description Create a new traceroute ses...

Страница 422: ...er of probes to send 1 10 Figure 7 517 CLI on line help on create command usage in this node context 7 6 18 5 2 remove command Name remove Description Remove an existing traceroute session Full path routing traceroute remove Mandatory Parameters ID Screen Output No Table 7 482 remove command information cli routing traceroute remove Usage REMOVE REMOVE Remove an existing traceroute session MANDATO...

Страница 423: ... 0 to 65535 Max TTL Maximum time to live for the traceroute probe Init TTL Initial time to live for the traceroute probe 1 to 255 Max Fails Max number of failed probes for each hop before the traceroute session in stopped 0 to 255 Table 7 484 show command output table parameters 7 6 18 5 4 showconfig command Name showconfig Description Print the command list that enforces the current configuration...

Страница 424: ...his node context Parameter Group Parameter Description ID Table entry identifier Active Flag Indicates if traceroute session is active Current TTL Current traceroute session time to live Current Hops Current number of traceroute hops Probes Sent Number of traceroute probes sent Success Number of traceroute probes with success Table 7 487 status command output table parameters 7 6 19 services node ...

Страница 425: ...s command usage in this node context Figure 7 526 Output of availableValues command in this node context Parameter Group Parameter Description Availabe Uplink interfaces Slot Indicates the slots with uplink interfaces Interfaces Indicates the OLT uplink interfaces Availabe Downlink interfaces Slot Indicates the slots with downlink interfaces Interfaces Indicates the OLT interfaces Table 7 489 avai...

Страница 426: ... del uplink ports Remove interfaces from the Uplink interface List for a given service format slot port slot all 3 1 3 5 7 dhcp Enable or disable the DHCP relay for a given service enable disable igmp Enable or disable IGMP for a given service enable disable mcFlood Multicast flooding enable disable nni stag Outer VLAN ID service on the network facing Ethernet interface 1 4094 pppoe Enable or disa...

Страница 427: ...vice enable disable stacked Frame format for the uplink interface If enabled it has two VLAN tags otherwise only one VLAN tag enable disable Figure 7 528 CLI on line help on create command usage in this node context About the service type Unicast Bidirectional service where each frame has only one final destination These services are used in Residential applications where some kinds of packets can...

Страница 428: ...No Screen Output Tables Figure 7 531 and Figure 7 532 Table parameters description in Table 7 494 and Table 7 495 Table 7 493 show command information cli services show Usage SHOW Show the current services configuration If a service ID is given shows all the downlink ports OPTIONAL serviceID Select an OLT service by ID Figure 7 530 CLI on line help on show command usage in this node context Figure...

Страница 429: ...all packets pass transparently by the system and MAC learning is disabled Stacked Provides the frame format in the uplink interface If it s Stacked the frame contains two vlan tags if it s Unstacked the frame contains only one vlan tag Both vlans have Ethertype 0x8100 MC Flood Indicates Multicast flooding configuration for a given service enable disable DHCP Identifies if the service must work has...

Страница 430: ...ervice must work has a DHCP Relay Agent PPPoE Enable or disable PPPoE for a given service enable disable IGMP Enable or disable IGMP for a given service enable disable NNI S TAG Identifies the outer tag of the service on the network facing Ethernet interface in the uplink port 1 4094 UNI C TAG Identifies the VLAN delivered received to from the Ethernet subscriber facing interface at the ONU 1 4094...

Страница 431: ...vices rate limiters show Mandatory Parameters No Screen Output Tables Figure 7 536 Table parameters description in Table 7 499 Table 7 show command information cli services rate limiters show Usage SHOW Show the current global rate limiters configuration Figure 7 CLI on line help on show command usage in this node context Figure 7 536 Output of show command in this node context Parameter Descripti...

Страница 432: ...ired interface Service statistics use a few resources on the hardware so they must activated when needed and disabled otherwise The information shown depends on the type of service each type of service will display a different table and different information 7 6 19 8 1 counters sub node This sub node is used to activate or deactivate the service counters 7 6 19 8 1 1 availableValues command Name a...

Страница 433: ...tatistics for a given service and interface whose counter has already been activated Full path services statistics counters show Mandatory Parameters serviceID Screen Output Table Figure 7 541 Table parameters description in Table 7 504 Table 7 503 show command information cli services statistics counters show Usage SHOW Show the statistics for a given service and interface whose counter has alrea...

Страница 434: ...ut table parameters 7 6 19 8 1 3 show active command Name Show active Description Display all active counters Full path services statistics counters show active Mandatory Parameters This command has no parameters Screen Output Table Figure 7 543 Table parameters description in Table 7 506 Table 7 505 show active command information cli services statistics counters show active Usage SHOW ACTIVE Dis...

Страница 435: ...ics counters start Usage START Start the statistics counter for a given interface and service MANDATORY serviceID Select an OLT service by ID OPTIONAL port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 Figure 7 544 CLI on line help on start command usage in this node context 7 6 19 8 1 5 stop command Name stop Description Stop an active statistics counter Full path services statistics c...

Страница 436: ... line help on availableValues command usage in this node context Figure 7 547 Output of availableValues command in this node context Parameter Description Service ID Name Available Service identified by Service ID number and Service Name Slot Slot number where is the port with the service available Port Port number where the service is available Table 7 510 availableValues command output table par...

Страница 437: ...mber of transmitted and received DHCP dropped packets Client Request Indicates the number of transmitted and received DHCP client request packets Without Options Option 82 Option 37 Option 17 Server Replies Indicates the number of transmitted and received DHCP server replies packets Without Options Option 82 Option 37 Option 17 Client Packets Trusted Number of dropped packets because they are clie...

Страница 438: ...7 513 availableValues command information cli services statistics igmp availableValues Usage AVAILABLEVALUES Display possible values for service IDs and Interfaces Figure 7 550 CLI on line help on availableValues command usage in this node context Figure 7 551 Output of availableValues command in this node context Parameter Description Service ID Name Available Service identified by Service ID num...

Страница 439: ...ure 7 552 CLI on line help on show command usage in this node context Figure 7 553 Output of show command in this node context Parameter Description Packets Rx Tx Total and Partial counters displayed Indicates the number of transmitted and received packets Total sum of all packets Dropped sum of all dropped packets Valid sum of all valid compliant with the IGMP standards packets Invalid sum of all...

Страница 440: ...c queries GroupandSourceSpecific oftypeGroupandSourcespecificqueries Table 7 516 show command output table parameters 7 6 20 synchronism node cli synchronism tree synchronism global config show showconfig sources availableValues config show showconfig ptp config show showconfig port availableValues config create remove show showconfig ip access list config create remove show status global command ...

Страница 441: ...m quality before squelch quality level mode Enables synchronism quality level enable disable reversibility level modeEnables revertive switching mode when recovering from a failure enable disable reversibility time Set the Reversibility time 0 3600 sec send val after quality unknown Set the value to be sent in case Quality Unknown is received switching msg delay Set the Switching message delay 180...

Страница 442: ...e status machine of the equipment only considers for synchronizationsource asourcethatdoesnotshowtimingflawsandwherethe Reversibility Time has expired If the quality priority of this source depending on the current configuration of the Quality Level Mode is higher than the current source the equipment will use this quality priority source Otherwise the source is not changed If Disabled a source th...

Страница 443: ...ctive Quality Level configured if there is no synchronization source with a Quality Level other than Quality Unknown Number of junctions Number of junctions that can be used for as synchronism source Source free run Source free run If enabled the system always synchronizes with its internal clock array unit PLL Table 7 519 show command output table parameters 7 6 20 1 3 showconfig command Name sho...

Страница 444: ...obal sources availableValues Usage AVAILABLEVALUES Show the available values for configurable parameters Can filter by source ID OPTIONAL ID Identifies a table entry by ID in this context Figure 7 559 CLI on line help on availableValues command usage in this node context Figure 7 560 Output of availableValues command in this node context Parameter Description ID Identifies a synchronism source by ...

Страница 445: ...ailableValues priority Set the clock source priority value 1 253 sa bit RX Configure SA bit used for reception of SSM packets 4 8 sa bit TX Configure SA bit used for transmission of SSM packets 4 8 wait to restore Amount of time before including a new clock source in clock selection 0 12 min Figure 7 561 CLI on line help on config command usage in this node context 7 6 20 1 4 3 show command Name s...

Страница 446: ... bit in the case of 2Mbps only for the synchronization junctions SA bit Rx Allows setting the value of the reception Sa bit in the case of 2Mbps only for the synchronization junctions Hold Off time ms The Hold Off time ensures that the activation even if short of the signal failure has no influence on the synchronization source selection process This value can vary between 300ms and 1800ms Wait To...

Страница 447: ...tch priority when criteria matches 1 253 slave only Enables slave only configuration of the PTP machine enable disable telecom profile Enables Telecom profile configuration of the PTP machine enable disable two step clock Enables Two step clock configuration of the PTP machine enable disable unicast negotiation Enables Unicast negotiation configuration of the PTP machine enable disable Figure 7 56...

Страница 448: ...file is enabled Unicast Negotiation Indicates if Unicast negotiation is enabled BMCA Indicates if BMCA is enabled Alternate Master Indicates if alternate master is enabled Table 7 529 show command output table parameters 7 6 20 2 3 showconfig command Name showconfig Description Print the command list that enforces the current configuration Full path synchronism ptp showconfig Mandatory Parameters ...

Страница 449: ...m ptp port availableValues Usage AVAILABLEVALUES Show the available values for configurable arguments Figure 7 569 CLI on line help on availableValues command usage in this node context Figure 7 570 Output of availableValues command in this node context Parameter Description Slot Indicates the slot Port Indicates the OLT interface Table 7 532 availableValues command output table parameters 7 6 20 ...

Страница 450: ...request minimum interval peer ip Specify the PTP clock port Peer IP address peer ip mask Specify the PTP clock port Peer IP Mask 0 32 pkt size Set the PTP config port packet size 86 1510 Bytes port Identifies an interface on the OLT e g pon 2 eth 3 lag 1 role Specify the PTP clock port role slave master self ip Specify the PTP clock port Self IP address self ip mask Specify the PTP clock port Self...

Страница 451: ...sk Specify the PTP clock port Peer IP Mask 0 32 pkt size Set the PTP config port packet size 86 1510 Bytes role Specify the PTP clock port role slave master self ip Specify the PTP clock port Self IP address self ip mask Specify the PTP clock port Self IP Mask 0 32 sync interval Set the synchronism message transmission interval vlan Choose a VLAN ID Figure 7 572 CLI on line help on create command ...

Страница 452: ... network facing Ethernet interface Role Indicates if the PTP port acts as a slave or as a master Self IP Indicates the origin PTP port IP address Self IP Mask Indicates the origin PTP port IP Mask Peer IP Indicates the destination PTP port IP address Peer IP Mask Indicates the destination PTP port IP Mask Table 7 537 show command output table parameters 7 6 20 2 4 6 showconfig command Name showcon...

Страница 453: ...le Set the access list entry role allow deny Figure 7 577 CLI on line help on config command usage in this node context 7 6 20 2 4 7 2 create command Name create Description Create Full path synchronism ptp port ip access list create Mandatory Parameters olt ptp port ID Screen Output No Table 7 540 create command information cli synchronism ptp port ip access list create Usage CREATE CREATE Create...

Страница 454: ...ll path synchronism ptp port ip access list show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 Table patrameters description in Table 7 Table 7 542 show command information cli synchronism ptp port ip access list show Usage SHOW Show the current configuration Figure 7 580 CLI on line help on show command usage in this node context Figure 7 581 Output of show comm...

Страница 455: ...nable clear a lockout configuration on the specified clock source clear lockout Figure 7 582 CLI on line help on command command usage in this node context 7 6 20 3 1 2 show command Name show Description Show the global status information Full path synchronism status global show Mandatory Parameters This command has no parameters Screen Output Table Figure 7 584 Table parameters description in Tab...

Страница 456: ...nce purposes commands These commands are independent and have different impacts on the selection processes Enablinganddisablingexternalcommandsassociatedwiththesynchronization selection process is defined below Only one of these external commands is enabled by the selection process at a time It is possible to carry out the following commands in the active synchronism sources Clear Manual Switch Fo...

Страница 457: ...igure 7 586 CLI on line help on show command usage in this node context Figure 7 587 Output of show command in this node context Parameter Description ID Indicates synchronization source Source Indicates synchronization source slot or junction number SSM Rx This column identifies the received SSM Synchronization Status Message SSM Used This column identifies the used SSM Signal Fail Signal failure...

Страница 458: ...tp show Usage SHOW Show the current status information Figure 7 588 CLI on line help on show command usage in this node context 7 6 21 users node cli users tree users config create remove show status Figure 7 589 users node tree 7 6 21 1 config command This command is only available for users with administrator s permissions Name config Description Configure an existing user login Full path users ...

Страница 459: ...ions Name create Description Create a new user login Full path users create Mandatory Parameters login permissions Screen Output No Table 7 552 create command information cli users create Usage CREATE Create a new user login MANDATORY login User s login permissions User s permissions OPTIONAL auto removal User s auto removal enable disable expire time User s expire time hours Figure 7 591 CLI on l...

Страница 460: ...meters This command has no parameters Screen Output Table Figure 7 594 Table parameters description in Table 7 555 Table 7 554 show command information cli users show Usage SHOW Show the current users login configuration Figure 7 593 CLI on line help on show command usage in this node context Figure 7 594 Output of show command in this node context Parameter Description Login Identifies a user by ...

Страница 461: ... on status command usage in this node context Figure 7 596 Output of show command in this node context Parameter Description Login Identifies a user by Users login Active Indicates if the user is active Remaining Time Indicates the remaining time till the user s login expires Table 7 Status command output table parameters 7 6 22 utils node cli utils tree utils ping tcpdump telnet traceroute Figure...

Страница 462: ...ute tcpdump Full path utils tcpdump Mandatory Parameters No Screen Output Yes Table 7 559 tcpdump command information cli utils tcpdump Usage TCPDUMP TCPDUMP Execute Tcpdump OPTIONAL dns resolv Translate IP addresses and port numbers using DNS true false filter Filter by protocol IP ports etc Syntax is equal to linux tcpdump src interface Set Source Interface verbosity Verbosity level 1 3 Figure 7...

Страница 463: ... telnet command usage in this node context 7 6 22 4 traceroute command Name traceroute Description Execute traceroute Full path utils traceroute Mandatory Parameters dst ip Screen Output Yes Table 7 561 traceroute command information cli utils traceroute Usage TRACEROUTE TRACEROUTE Execute Traceroute MANDATORY dst ip Set Destination IP Address OPTIONAL dns resolv Translate IP addresses and port nu...

Страница 464: ...y service configured at the ONT RGW must have as associated interface the VEIP Virtual Ethernet Interface Port OLT configuration tables for this ONT RGW at the Services tables for the service not working select the view link at the details column to view the service configuration details at the port configuration verify is VEIP is the associated port if not correct it An ONU equipment just added i...

Страница 465: ...e 0x0D034322 Invalid protection group reversibility 0x0D034323 Invalid protection group wait to restore value 0x0D034324 Invalid protection group hold off timer value 0x0D034325 Invalid protection group primary port 0x0D034326 Invalid protection group protection port 0x0D034327 Protection group primary port is not active 0x0D034328 Protection group protection port is active 0x0D034330 The ports of...

Страница 466: ... are removed 0x1D0348C8 Unable to configure a downstream traffic profile on unstacked services 0x1D0348C9 NNI C Tag is used by another Client Service associated with a Network Service with the same NNI S Tag 0x1D0348CA The selected ethernet profile does not exist 0x1D0348CB The selected upstream profile does not exist 0x1D0348CC The service has no T CONTs mapping 0x1D0348CD The service has T CONTs...

Страница 467: ...id enable value 0x1D03A421 Invalid association type 0x1D03A422 Invalid associated entity ID 0x1D03A423 Invalid input TPID 0x1D03A424 Invalid output TPID 0x1D03A425 Invalid DSCP to P Bit mapping profile 0x1D03A430 The port has services 0x1E034893 For unicast multicat services the pair service type uni vlan has to be unique in the OLT 0x1E0348DD Stacked services can only have one uplink port 0x1E034...

Страница 468: ...0x65030114 Invalid ACL rule precedence 0x65030115 Invalid ACL rule flow label 0x65030116 Maximum number of rules per ACL reached 0x65030117 Cannot remove disable the last rule for an ACL with enabled associations 0x65030118 ACL interface association invalid administrative state 0x65030119 ACL interface association invalid direction 0x65030120 ACL interface association invalid interface id 0x650301...

Страница 469: ...andwidth Allocation DHCP Dynamic Host Configuration Protocol DMAC Destination MAC address E1 European digital transmission format 1 ETH Ethernet ETSI European Telecommunications Standards Institute FEC Forward Error Correction FSAN Full Service Access Network GbE Giga bit Ethernet GEM GPON Encapsulation Mode GPON Gigabit capable Passive Optical Network ICC ITU T Carrier Code ID Identification IEEE...

Страница 470: ...undary with the same MEG Level and MEG ID MEG ID Maintenance Entity Group Identifier Equivalent to the IEEE term Maintenance Association Identifier MAID An identifier for a MEG unique over the domain that SOAM is to protect against the accidental concatenation of service instances MEP Maintenance association End Point IEEE 802 1ag or equivalently MEG End Point ITU T Y 1731 An actively managed SOAM...

Страница 471: ...Pluggable transceiver PDU PDU Protocol Data Unit PDV Packet Delay Variation QoS Quality of Service RF Radio Frequency RG Residential Gateway RIP Routing Information Protocol RMEP Remote MEP NG PON Next Generation Passive Optical Network SC APC SC APC Fiber Optic Connector SC PC SC PC Fiber Optic Connector SDH Synchronous Digital Hierarchy SFP Small Form factor Pluggable transceiver SONET Synchrono...

Страница 472: ...avelength Division Multiplexing UMC Unique MEG ID code USB Universal Serial Bus UTP Unshielded Twisted Pair VLAN Virtual Local Area Network VoIP Voice over Internet Protocol SFP 10 Gigabit Small Form Factor Pluggable transceiver XGPON Extra Large Gigabit Passive Optical Network ...

Страница 473: ...EN 473 ...

Страница 474: ......

Страница 475: ......

Страница 476: ......

Страница 477: ...EN 477 ...

Страница 478: ...Descripción del producto 478 ...

Страница 479: ...EN 479 ...

Страница 480: ...Descripción del producto 480 ...

Страница 481: ...EN 481 ...

Страница 482: ...Descripción del producto 482 ...

Отзывы: