Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
78
DEV 02
COMM
ADDRESS
8024
OPERATION
814 + 02
TEXT MENU
9. DEVICES – 02. DEVICE [NAME] – 5. COMM QUALITY
Communication quality for Device 02.
The engineer can check the quality of communication between the Device 02 and the control panel).
This address is only for review. The communication quality is described with signal strength, the
number of sent packets and the number of repeated packets.
Default setting: N.A.
The following menus are available for proximity cards readers only.
DEV 02
ARM MODE A
ADDRESS
8027
OPERATION
817 + 02
TEXT MENU
9. DEVICES – 02. DEVICE [PRX] – 6. ARM MODE A
ARM Mode A for Device 02
At this address the engineer can set a configuration for operation (arming and/or disarming) of all
areas in the system. This combination of disarm and arming types is set for every of the areas,
provides the ARM MODE A for the proximity card reader. The ARM MODE A operation does not
depend on the programmed on address 8xx1.
To activate the ARM MODE A, the user has to approach and hold a valid card in front of the proxy
reader for a 2-3 sec until the green LED lights on.
The engineer can set one or more areas to operate in ARM MODE A
– that depends on the system
configuration and organization. To set an ARM type or disarm use the buttons:
Button Operation
Indication
LCD
LED
LED8/ 16A
0
No change of the Area state
[
]
[10]
Button [0]
1
Disarm
[d]
[1]
Button [1]
2
Full ARM
[f]
[2]
Button [2]
3
Stay ARM
[s]
[3]
Button [3]
4
Sleep ARM
[S]
[4]
Button [4]
Indication:
LCD: The respective letter for the chosen operation for the area is displayed on the screen.
LED: After entering the address, the system shows the set type for the Area 1. Use the arrow buttons
to review the set types for the other Areas. To change the arming type, press the button
corresponding to the respective operation. Every pressing of a button sets the new arming type and
moves on to the next area number.
Default setting: Area 1
– [s] Stay ARM
DEV 02
ARM MODE B
ADDRESS
8028
OPERATION
818 + 02
TEXT MENU
9. DEVICES – 02. DEVICE [PRX] – 7. ARM MODE B
ARM Mode B for Device 02
The programming of this address is analogical to the one described for address 8027. This
combination of disarm and arming types is set for every of the areas, provides the ARM MODE B for
the proximity card reader.
To activate the ARM MODE B, the user has to approach and hold a valid
card in front of the proxy reader for a 3-4 sec until the yellow LED lights on.
Default setting:
Area 1
– [S] Sleep ARM
The Device numbers 03 to the maximum for the panel version are programmed in an analogical way.
When there is no enrolled
device to the address 8xx0,
a message “No device!” is
displayed at address 8xx4,
where “xx” is the device
number.