CONF.
TIMER
ADDRESS
0014
OPERATION
014
TEXT MENU
2. SETTINGS – 04. CONF. TIMER
“Confidential Mode” Timer
This parameter is common for all keyboards. Enter a time from 10 to 180 seconds.
The “Confidential mode” is a special mode for hiding the information for the activated zones and used
areas. The mode is assigned for every keyboard at address 8xx2 (Device Options), with enabling the
options 3 and 4
– see the detailed description in Menu 8. Peripheral Devices.
Parameter by default: 010 (10 seconds)
AC DELAY
ADDRESS
0015
OPERATION
015
TEXT MENU
2. SETTINGS – 05.AC DELAY
AC Power Supply Failure Indication Delay
Programming of time for delay indication in case of 220 VAC power supply failure.
Enter a time from 0 to 255 minutes. The set time is confirmed with ENTER button.
In case of using a LED keyboard, you can review the set time with arrow buttons. The blinking zone
number indicates a programming mode for that value. A permanently lit zone number shows the
current set value (10 means 0). To change it, press other digit button
– the cursor automatically
moves on the next value to the right.
If by mistake the installer enters bigger time than maximal of 255 minutes, the keyboard will reject the
entered value and will display the maximal possible one.
Parameter by default: 030 (30 minutes)
SOUND
TMPR
ADDRESS
0016
OPERATION
016
TEXT MENU
2. SETTINGS – 06.SOUND TMPR
Programming of Silent/ Audible Sound TAMPER signal
Programming of silent or audible TAMPER event (a zone TAMPER type or physical tamper-switch is
open) when the system is disarmed.
At this address, you set the parameter as:
DISABLE
Silent
TAMPER
In case of a TAMPER event:
- The LED indication is activated;
- TAMPER Outputs type are activated (the ALARM and SIREN outputs type are not
activated);
- A TAMPER alarm message is send to monitoring station (via PSTN, GPRS or LAN).
ENABLE
Audible
TAMPER
In case of a TAMPER event:
- The LED indication and the internal buzzer of the keyboards are activated and can
be cleared only after entering of valid user code;
- A TAMPER alarm signal activated (activation of outputs type ALARM, SIREN and
ТАМPER);
- A TAMPER alarm message is send to monitoring station (via PSTN, GPRS or LAN).
Programming this address will not affect the TAMPER signal when the system is in armed mode.
Programming this address will affect the performance of the programmable outputs type SIREN,
ALARM and TAMPER, the LED and sound indication of the keyboards and the digital communicator
when the system is disarmed.
Every pressing of a digital button alternatively changes the enabled / disabled status. The display
indication is shown in the table.
Parameter by default: ENABLE (audible TAMPER)