Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
79
APPENDIX
APPENDIX 1. Structure of zone inputs on the ECLIPSE 32 control panel
The zone numbers 09
– 16 are logical corresponding to the physical hardware terminals (connection styles 6 - 9):
Physical
inputs
Z1
Z2
Z3
Z4
…
Z8
Logical inputs
in doubling
mode
1
9
2
10
3
11
4
12
8
16
Zone number
01
aa
02
bb
03
cc
04
dd
08
hh
ADDRESS
2010
2aa0
2020
2bb0
2030
2cc0
2040
2dd0
2080
2hh0
Description
[1] [1]
[01] [09]
[1] [2]
[01] [10]
[1] [3]
[01] [11]
[1] [4]
[01] [12]
[1] [8]
[01] [16]
Fixed positions
Programmed positions.
For the respective zone is necessary to attach a number of device and logical input!
APPENDIX 2. Memory LOG Events
Event
number
LED
Indication
Description
System
Event (LOG)
Zone/
User
CID
Code
SIA
Code
1
Burglary Alarm event
Z## Alarm
Zone No/ name
1 13A
BA
2
Burglary Alarm event restore
Z## Alarm R
Zone No/ name
3 13A
BH
3
Fire Alarm event
Z## Fire
Zone No/ name
1 11A
FA
4
Fire Alarm event restore
Z## Fire R
Zone No/ name
3 11A
FH
5
Panic Alarm event
Z## Panic
Zone No/ name
1 12A
PA
6
Panic Alarm event restore
Z## Panic R
Zone No/ name
3 12A
PR
7
Tamper Alarm event
Z## Tamper
Zone No/ name
1 137
TA
8
Tamper Alarm event restore
Z## Tamper R
Zone No/ name
3 137
TR
9
Medical Alarm event
Z## Medical
Zone No/ name
1 1AA
MA
10
Medical Alarm event restore
Z## Medical R
Zone No/ name
3 1AA
MR
11
Activated zone with
„24h Burglary"
AUX attribute
Z## 24h Alarm
Zone No/ name
1 13A
BA
12
Restored zone with
„24h Burglary"
AUX attribute
Z## 24h Alarm R
Zone No/ name
3 13A
BH
13
Activated zone with
AUX „AC
Loss" attribute
Z## AC Loss
Zone No
1 3A1
AT
14
Restored zone with
AUX „AC
Loss" attribute
Z## AC Restore
Zone No
3 3A1
AR
15
Activated zone with
AUX „Battery
Low" attribute
Z## Batt Low
Zone No
1 3A2
YT
16
Restored zone with
AUX „Battery
Low" attribute
Z## Batt Restore
Zone No
3 3A2
YR
17
Activated zone with
AUX „Water
leakage" attribute
Z## Water leak
Zone No
1 154
WA
18
Restored zone with
AUX „Water
leakage" attribute
Z## Water leak R
Zone No
3 154
WR
19
Activated zone with
AUX „GAS
Detector" attribute
Z## Gas
Zone No
1 151
GA
20
Restored zone with
AUX „GAS
Detector" attribute
Z## Gas R
Zone No
3 151
GR
21
Activated zone with
AUX „GSM
Link Trouble" attribute
Z## GSM Link
Zone No
1 354
YS
22
Restored zone with
AUX „GSM
Link Trouble" attribute
Z## GSM Link R
Zone No
3 354
YK