Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
80
23
Activated zone with
AUX „GAS
Trouble" attribute
Z## Gas Trbl
Zone No
1 157
GT
24
Restored zone with
AUX „GAS
Trouble" attribute
Z## Gas Trbl R
Zone No
3 157
GR
25
Activated zone with
AUX „High
temperature" attribute
Z## High Temp
Zone No
1 158
KA
26
Restored zone with
AUX „High
temperature" attribute
Z## High Temp R
Zone No
3 158
KR
27
Activated zone with
AUX „Low
temp" attribute
Z## Low Temp
Zone No
1 159
ZA
28
Restored zone with
AUX „Low
temp" attribute
Z## Low Temp R
Zone No
3 159
ZR
29
Activated zone with
AUX „Loss of
heat" attribute
Z## Heat Loss
Zone No
1 153
ZA
30
Restored zone with
AUX „Loss of
heat" attribute
Z## Heat Loss R
Zone No
3 153
ZR
31
Activated zone with
„Write to
LOG"
(1)
attribute
Z## Open
Zone No
-
-
32
Restored zone with "Write to
LOG"
(1)
attribute
Z## Close
Zone No
-
-
33
Zone Bypass
Z## Bypassed
Zone No/ name
1 57A
UB
34
Zone Bypass restore
Z## UnBypassed
Zone No/ name
3 57A
UU
35
Quick arming
– FULL ARM
QuickArm A#
Area No/ name
3 4A8
CL
36
Quick arming
– STAY ARM
QuickArm A#Stay
Area No/ name
3 4A8
CL
37
Quick arming
– SLEEP ARM
QuickArm A#Inst
Area No/ name
3 4A8
CL
38
Arming with user code - FULL
U##Arm A#
User/Area No
3 4A1
CL
39
Arming with user code - STAY
U##Arm A#Stay
User No/ name
3 4A1
CL
40
Arming with user code - SLEEP
U##Arm A#Inst
User No/ name
3 4A1
CL
41
Disarming with user code
U##Disarm A#
User/Area No
1 4A1
OP
42
Remote arming - FULL
U##RemArm A#
User/Area No
3 4A7
CQ
43
Remote arming - STAY
U##RemArm A#Stay
User No/ name
3 4A7
CQ
44
Remote arming - SLEEP
U##RemArm A#Inst
User No/ name
3 4A7
CQ
45
Remote disarming
U##RemDisarm A#
User/Area No
1 4A7
OQ
46
Arming with keyswitch - FULL
Z##KeyArm A#
Zone/Area No
3 4A9
CS
47
Arming with keyswitch - STAY
Z##KeyArm A#Stay
Zone No/ name
3 4A9
CS
48
Arming with keyswitch - SLEEP
Z##KeyArm A#Inst
Zone No/ name
3 4A9
CS
49
Disarming with keyswitch
Z##KeyDisarm A#
Zone/Area No
1 4A9
OS
50
FULL Arming on TimeSlot
AutoArm A#
Area No
3 4A3
CA
51
STAY Arming on TimeSlot
AutoArm A#Stay
Area No
3 4A3
CA
52
Disarming on TimeSlot
AutoDisarm A#
Area No
1 4A3
OA
53
FULL Arming on
“no movement”
AutoArm A#
Area No
3 4A3
CA
54
STAY Arming on
“no movement”
AutoArm A#Stay
Area No
3 4A3
CA
55
Bypass of zone with FORCE
attribute when arming
Z## Forced
Zone No/ name
1 57A
UB
56
Debypass of zone with FORCE
attribute when disarming
Z## Included
Zone No/ name
3 57A
UU
57
Arm Delay on Timeslot
U## ArmExtend A#
User/Area No
1 464
CE
58
Ambush code entered
U## Duress Alarm
User No/ name
1 121
HA
59
Medical panic alarm sent from
keyboard
KBD## Medical
Keyboard No
1 1AA
MA
60
Medical panic alarm from keyboard
restored
KBD## Medical R
Keyboard No
3 1AA
MR
61
Police panic alarm sent from
keyboard
KBD## Panic
Keyboard No
1 12A
PA