Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
68
2
TAMPER
Message is sent in case of events:
- TAMPER (from a zone; from a Tamper type zone; from a
device connected to the system bus: keyboard, proxy reader,
expander modules)
- TAMPER Restore
3
PANIC, AMBUSH CODE
Message is sent in case of events:
- PANIC (from a zone; from a keyboard)
- Entered AMBUSH CODE
4
FIRE
Message is sent in case of events:
- FIRE (from a zone; from a keyboard)
- FIRE Restore
5
ARM, DISARM, BYPASS
Message is sent in case of events:
- ARMING
- DISARMING
- ZONE BYPASS
6
MEDICAL
Message is sent in case of events:
- MEDICAL ALARM
- MEDICAL ALARM Restore
7
TROUBLE
Message is sent in case of the troube/ trouble restore events:
1. AC Lost/ failure
2. Battery Lost/ Failure
3. Fuse Blown
4. Communication Lost
5. Error on the system bus
8
SPECIAL
Message is sent in case of events:
-
Keyboard lockout
- Engineer menu entry
- Engineer menu exit
- Download start
- Download end
- Periodic Test Report
- Manual Test Report
- Power Up
- Reset
- Time Changed
- Absent (device)
- Restored (device)
- User Code Change
Default setting: All messages enabled
PH1
AREAS
ADDRESS
6013
OPERATION
613 + 01
TEXT MENU
8. COMMUNICATION – 1. DIGITAL COMM – 5. PHONES – 1. PHONE – 4. ATTACH
Associating of areas to Telephone 1 of the digital communicator
According the system configuration the engineer associates one or several AREA numbers for
operation with Telephone 1. To select an AREA press the digit button corresponding to its number.
The next pressing of the same button will deselect the AREA.
To select all areas press
button “0” – the button alternatively switches over all enabled / all disabled
state.
The Telephone 1 will be inactive if there are no associated areas to it!
Default setting: AREA 1
The second telephone number for ECLIPSE 8/ 16 and from 2 to 4 for ECLIPSE 32 are programmed in an analogical
way.