![TELES ECOTEL Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/teles/ecotel/ecotel_manual_1082146092.webp)
R O U T I N G E X A M P L E S
C H A P T E R 6
92
ECOTEL 3G 16.1. Revised: 1 March 2011.
Configuration in the pabx.cfg
Configuration in the route.cfg
6 . 4 E C O T E L A S A S E C O N D - G E N E R A T I O N L C R
In the following example of a PBX connection,
all international calls are terminated to VoIP
(
40
). The VoIP carrier profile
DF
and the SIP
protocol are used. Block dialing is used, and
the last digit waits three seconds. National
calls are routed through the carrier with the
prefix
01078
. All other calls are sent to the
PSTN unchanged. All calls from the PSTN or
from a VoIP carrier are sent directly to the NT
controller, to which the PBX is attached.
For the VoIP profile
DF
, the system uses the
registrar
reg
and registers with
myself.home.com
, username
user
and
password
pwd
. SIP UDP is used for signaling.
A maximum of 8 media channels with the G.729 codec can be used. The peer’s IP address is 192.168.0.10.
...
Controller00 = 30 FXS
Controller01 = 30 FXS
Controller02 = 30 FXS
Controller03 = 30 FXS
Controller04 = 20 UMTS
Controller05 = 20 UMTS
Controller06 = 20 UMTS
Controller07 = 20 UMTS
...
Subscriber00 = TRANSPARENT ROUTER ANA[0049,16]
Subscriber01 = TRANSPARENT ROUTER ANA[0049,16]
Subscriber02 = TRANSPARENT ROUTER ANA[0049,16]
Subscriber03 = TRANSPARENT ROUTER ANA[0049,16]
Subscriber04 = TRANSPARENT ROUTER UMTS[0000,00000,+491555555,1,1,1,SIM4] ALARM NEXT
Subscriber05 = TRANSPARENT ROUTER UMTS[0000,00000,+491555555,1,1,1,SIM4] ALARM
Subscriber06 = TRANSPARENT ROUTER UMTS[0000,00000,+491555555,1,1,1,SIM4] ALARM
Subscriber07 = TRANSPARENT ROUTER UMTS[0000,00000,+491555555,1,1,1,SIM4] ALARM
...
[System]
DTMFWaitDial=5
Restrict30=pl
MapAllpl=|20<<24
Restrict20=pbx
MapAllpbx=30
Bear in mind that emergency calls must be routed to the PSTN.