Example:
Tftpd=<mode>
Activates (
on
) or deactivates (
off
) TFTP access. Default
off
.
RemotePassword=<password>
Defines the password for FTP and GATE Manager access. Please refer to Chapter 4.11.4
for instructions
on how to enter an encrypted password in the
pabx.cfg
. If you do not define a password, access to the
system via GATE Manager occurs without a password, and FTP access occurs with the default password
tcs-ag
.
SimCtrlUnitAddress=<ip addr>
Enter the vGATE Control Unit’s IP address. For a detailed description of ECOTEL configuration for connection
to a vGATE, see Chapter 9.1
.
DialTone=<country>
If the system is used in a corporate settings and attached through a PBX to the PSTN, it may be necessary to
generate the carrier’s dial tone. It depends on whether the system sends the dialed digits to the PSTN or
whether it waits for a routing entry to take the call.
The following values can be entered:
GE
DE
IR
UK
US
FR
IT
VoipGlobalMaxChan=8
H225Port=1720
SipPort=5060
VoipRtpPort=29000
VoipRtpPortSpacing=2
StunServerAddress=172.16.0.1
StunServerPollInterval=600
NameServer=192.168.0.254
Timezone=Europe/Berlin
NtpServer=192.168.0.254
DialTone=GE
Table 5.18
pabx.cfg: IP Configuration System Parameters