Telecast Fiber Systems – CopperHead FS790 ProHD Transceiver System User Guide –
110124V4JH
Page 58
6.1. Set Up of the CopperHead FS-790 Transceiver System for operation
This section provides an overview of setup of the CopperHead FS-790 Transceiver System for operation. The
following sections provide additional detail on each aspect of setup and operation.
It is important that you do an initial setup and test of your CopperHead FS-790 Transceiver System as soon as
your receive in order to confirm proper operation and to provide training to you and your team prior to an
actual production.
Use the following list of items as an overall checklist for setup.
1. It is highly recommended that you do not attempt to power up the system until all connections are
made and in particular the Fiber Optic Cable has been connected at both ends. If you need to power
up either the CopperHead FS-790 Base Station or Camera Unit make sure that the fiber connectors
are securely capped. This will protect them from damage or dirt and protect you from eye damage.
2. If it is the first time setting up the CopperHead RM-FP790 Base Station or your setup is not
permanent as it would likely be in a remote truck, stadium control room or similar, connect all
required cables. The order in which you connect the cables makes no difference.
a. Make sure to connect the Base Remote cable to the Base Station and Remote Control Panel
when the Base Station power is turned off.
b. Keep Fiber Optic cable connectors capped until actually connecting the Fiber Cable.
3. When setting up the CopperHead KA-FP790 Camera Unit and attached GY-HM790 Camera you will
need to do the following:
a. Setup the external power supply as required. Make sure all cables running between the
CopperHead FS-790 Base Station and the Power Supply and local AC power cords are
properly managed and secured.
b. Connect all required cables according to Chapter 5. The order in which you connect the
cables makes no difference.
c. Set up the Intercom Talk Back switches and level controls as desired. Please see the following
Section 6.4 on Page 63 for details on Intercom operation with the CopperHead KA-FP Series
Camera Unit.
4. Deploy the Fiber Cable (see the next section) – you are now ready to apply power to the system.
Содержание CH3-MPS-95VD-2ST-304
Страница 2: ......
Страница 86: ...CH FS790 110124V4JH Telecast Fiber Systems A Belden Brand ww telecast fiber com 2011...