Performance Check— 2445 Service
c.
Adjust the SEC/DiV VAR control for a sweep-speed
readout (on bottom line) of 20
ms
and adjust the Time-Mark
Generator variable timing control for exactly 2 time markers
per division.
d.
CHECK—The Time-Mark Generator variable timing
% of error has changed 2% or less from the reading noted in
part b.
e. Adjust the SEC/DIV VAR control fully CCW.
f. CHECK— Sweep speed readout displays 30.0
ns.
Input Coupling
CH 1
IMS] DC
CH 2
1 Mfi GND
b.
Connect a 50 mV standard-amplitude signal from the
Calibration Generator to the CH 1 OR X input connector via
a 50 Q BNC cable.
c.
CHECK— Signal display amplitude is 4.9 to 5.1 hori
zontal divisions.
d. Disconnect the test setup.
g.
Set the Time-Mark Generator variable timing control
for exactly 3 time markers per division.
h.
CHECK—The Time-Mark Generator variable timing
% of error has changed 2% or less from the reading noted in
part b.
7. Check X-Axis Bandwidth.
a. Set the CH 1 Input Coupling to 50
Q
DC.
b.
Connect a 50 kHz signal from the Leveled Sine-Wave
Generator to the CH 1 OR X input connector via a precision
50 Q BNC cable.
i. Set:
A SEC/DIV
B SEC/DIV
SEC/DIV VAR
At
AREF OR DLY POS
B TRIGGER
MODE
50
ms
10
ms
(knob in)
CW (in detent)
Off (DLY readout)
Zero delay
RUN AFT DLY
j. Repeat parts b through h for the B Sweep.
c.
Set the generator output for a 6-division horizontal
display.
d. Change the generator frequency to 3 MHz.
e. CHECK— Signal display is
4.2 horizontal divisions.
8. Check X-Y Phase Differential.
a.
Set the Leveled Sine-Wave Generator for a 1 MHz, 6-
division horizontal display.
k.
Rotate the SEC/DIV VAR control CW to the detent
position and disconnect the test setup.
b.
Press and release the CH 2 VERTICAL MODE switch
( CH 2 o ff). CH 1 displays automatically.
6. Check X-Axis Gain.
a. Set:
VERTICAL MODE
CH 2
CH 1, CH 3, CH 4,
ADD, and BW LIMIT
A and B SEC/DIV
VOLTS/DIV
CH 1 and CH 2
On (button in)
Off (buttons out)
X-Y (knobs locked)
10 mV
c.
Use the CH 1 VERTICAL POSITION control to verti
cally center the display on the graticule.
d.
CHECK— Elipse opening is 0.1 division or less, mea
sured horizontally.
e. Press in the CH 2 VERTICAL MODE switch (CH 2
on).
4-24
Содержание 2445
Страница 1: ...Tektronix 2445 OSCILLOSCOPE SERVICE INSTRUCTION MANUAL ...
Страница 11: ...2445 Service 3829 01 The 2445 Oscilloscope ...
Страница 44: ...Theory of Operation 2445 Service 3831 10A Figure 3 1 Block diagram ...
Страница 45: ...Theory of Operation 2445 Service 3831 10B Figure 3 1 Block diagram cont 3 3 ...
Страница 210: ...3829 58 Figure 9 4 2445 block diagram ...
Страница 214: ......
Страница 217: ......
Страница 219: ...2445 382 72 ...
Страница 222: ...2445 ...
Страница 231: ...A 1 t C t t F t G t H t ...
Страница 233: ......
Страница 236: ......
Страница 238: ...2445 392 1 75 ...
Страница 244: ......
Страница 247: ...A 1 C _____ D E F G H J 2445 3811 74 ...
Страница 248: ...1 2 3 4 5 6 7 8 9 i o 2445 DISPLAY SEQUENCER TRIG GERING A4B SWEEPS ...
Страница 253: ......
Страница 263: ... 0 2445 J8 i S ...
Страница 264: ...1 2 3 4 5 6 7 i 8 I i 9 10 2445 READOUT ...
Страница 275: ......
Страница 278: ......
Страница 281: ......
Страница 283: ... 8VJNR EG 3S 5 fROM P232 5 10 A 15VUNREG 8S F R O Mn i 2445 3 0 2 S 8 I ...
Страница 286: ...2445 3823 82 ...
Страница 290: ...B H le w o q 87V T S o I R v n i U1 R1873 PARTIAL A9 HIGH VOLTAGE BOARD 2445 ...
Страница 299: ...2445 Service DAC REF A5 CONTROL ADJUSTMENT LOCATIONS 3 ...
Страница 300: ......
Страница 301: ...J119 O A A Z fio rv ic A J118 VERT READOUT JITTER R618 i x n n t o i n R801 X10 GAIN R850 3829 71 ...
Страница 304: ...2 R E TU R N T O 1 ...
Страница 305: ...ERROR MESSAGE DIAGNOSTICS ...
Страница 306: ...ERROR MESSAGE DIAGNOSTICS ...
Страница 307: ...O A A C t rnra g i tiw c t 3829 89 ...
Страница 308: ...RETURN TO ...
Страница 309: ...FRONT PANEL TROUBLESHOOTING ...
Страница 310: ...FRONT PANEL TROUBLESHOOTING ...
Страница 311: ...2445 Service 3829 90 ...
Страница 316: ...R E TU R N T O v 1 y ...
Страница 317: ...SWEEP TROUBLESHOOTING PROCEDURE ...
Страница 318: ...2445 Service NOTE 3 56V IS M E A S U R E D A S 1 44V W ITH R ESPEC T TO TH E 5V SUPPLY 3829 95 ...
Страница 323: ......
Страница 324: ...2445 Service 3829 85 ...
Страница 325: ......
Страница 326: ... KERNEL NOP DIAGNOSTIC PROCEDURE ...
Страница 327: ...10 POWER SUPPLY TROUBLESHOOTING PROCEDURE 3829 94 ...
Страница 330: ......
Страница 334: ...2445 Service REGULATOR TROUBLESHOOTING PROCEDURE 3829 93 ...
Страница 338: ......
Страница 346: ...12 2445 SERVICE ...
Страница 347: ...2445 SERVICE ...
Страница 348: ...2445 SERVICE ...