Performance Check— 2445 Service
p.
Rotate the TRACE SEP control CCW to separate the
traces.
q.
Adjust the AREF OR DLY POS control to intensify the
2nd and 10th time markers (of the A sweep) and display the
leading edges of the displayed B sweep time markers in the
center area of the graticule.
r.
VERIFY—The horizontal distance between the lead
ing edges of the B sweep time markers is within the conser
vative guideline listed in Table 4-9. If this guideline is met,
accuracy between each marker is ensured, and the follow
ing CHECK step need not be performed.
s.
CHECK—The horizontal distance between the lead
ing edges of the B sweep time markers is within the speci
fied limits given in Table 4-9. The limit given is for separation
between the 2nd and 10th marker; however, separation be
tween the 2nd marker and each suceeding marker should
also be checked, calculating the limits from the specification
as listed at the top of the table.
t.
Repeat part r (and s if necessary) for each combina
tion of A SEC/DIV, B SEC/DIV, and X I0 MAG settings list
ed in Table 4-9. The At readout should be set to indicate
eight times the A SEC/DIV setting. At the slowest sweep
speeds, the B SEC/DIV knob will need to be pushed in
(B Sweep only) to increase the display repetition rate.
4. Check Delay Jitter.
a. Set:
TRACKING
Off (button out)
A SEC/DIV
1 ms
B SEC/DIV
0.5
ii
s (knob out)
b. Select 1 ms time markers from the Time-Mark
Generator.
c.
Aiign the intensified zones with the 10th time marker
using the AREF OR DLY POS and A controls. Superimpose
the zones to obtain a At readout display of 0.000 ms.
d.
Push in the B SEC/DIV knob and adjust TRACE SEP
to separate the traces.
e.
CHECK— For 0.8 division or less of horizontal jitter on
the rising edge of both time markers.
Table 4-9
Delayed Sweep Delta Time Accuracy
A SEC/DIV
and Time
Markers
B SEC/DIV
as Displayed
on Readout
Displayed Separation of
Delayed Time Markers
(for 2nd and 10th markers)
Conservative
Guideline
(divisions)
Specified
Limit:
(± 0 .3 % time)
interval
+0.1% of
full scale
(divisions)
0.1
ns
1 nsa
2 .4
3 .4
0 .2
ns
2 nsa
2 .4
3 .4
0 .5
ns
5 nsb
2 .4
3 .4
1
fiS
1 0 ns
2 .4
3 .4
2
ns
2 0 ns
2 .4
3 .4
5
ns
5 0 ns
2 .4
3 .4
1 0 jus
1 0 0 ns
2 .4
3 .4
2 0
ns
2 0 0 ns
2 .4
3 .4
5 0
ns
5 0 0 ns
2 .4
3 .4
0.1 m s
1
its
2 .4
3 .4
0 .2 m s
2
ns
2 .4
3 .4
0 .5 m s
5
ns
2 .4
3 .4
1 m s
1 0
ns
2 .4
3 .4
2 m s
2 0
its
2 .4
3 .4
5 ms
5 0
ns
2 .4
3 .4
10 ms
1 0 0
its
2 .4
3 .4
2 0 ms
2 0 0
ns
2 .4
3 .4
5 0 ms
5 0 0
ns
2 .4
3 .4
0.1 s
1 ms
2 .4
3 .4
0 .2 s
2 m s
6 .4
7 .4
0 .5 s
5 m s
6 .4
7 .4
a X I0 MAG On (button in).
b For remainder of Table, turn X I0 MAG off.
5. Check A and B SEC/DIV VAR Range and
Accuracy.
a. Set:
A and B SEC/DIV
10
ns
(knobs locked)
A and B SEC/DIV VAR
In detent
At
Off (press and release
to eliminate At
readout)
b.
Select 10
ns
time markers from the Time-Mark Gener
ator and adjust the Time-Mark Generator variable timing
control for exactly 1 time marker per division. Note the vari
able timing % error on the Time-Mark Generator.
4-23
Содержание 2445
Страница 1: ...Tektronix 2445 OSCILLOSCOPE SERVICE INSTRUCTION MANUAL ...
Страница 11: ...2445 Service 3829 01 The 2445 Oscilloscope ...
Страница 44: ...Theory of Operation 2445 Service 3831 10A Figure 3 1 Block diagram ...
Страница 45: ...Theory of Operation 2445 Service 3831 10B Figure 3 1 Block diagram cont 3 3 ...
Страница 210: ...3829 58 Figure 9 4 2445 block diagram ...
Страница 214: ......
Страница 217: ......
Страница 219: ...2445 382 72 ...
Страница 222: ...2445 ...
Страница 231: ...A 1 t C t t F t G t H t ...
Страница 233: ......
Страница 236: ......
Страница 238: ...2445 392 1 75 ...
Страница 244: ......
Страница 247: ...A 1 C _____ D E F G H J 2445 3811 74 ...
Страница 248: ...1 2 3 4 5 6 7 8 9 i o 2445 DISPLAY SEQUENCER TRIG GERING A4B SWEEPS ...
Страница 253: ......
Страница 263: ... 0 2445 J8 i S ...
Страница 264: ...1 2 3 4 5 6 7 i 8 I i 9 10 2445 READOUT ...
Страница 275: ......
Страница 278: ......
Страница 281: ......
Страница 283: ... 8VJNR EG 3S 5 fROM P232 5 10 A 15VUNREG 8S F R O Mn i 2445 3 0 2 S 8 I ...
Страница 286: ...2445 3823 82 ...
Страница 290: ...B H le w o q 87V T S o I R v n i U1 R1873 PARTIAL A9 HIGH VOLTAGE BOARD 2445 ...
Страница 299: ...2445 Service DAC REF A5 CONTROL ADJUSTMENT LOCATIONS 3 ...
Страница 300: ......
Страница 301: ...J119 O A A Z fio rv ic A J118 VERT READOUT JITTER R618 i x n n t o i n R801 X10 GAIN R850 3829 71 ...
Страница 304: ...2 R E TU R N T O 1 ...
Страница 305: ...ERROR MESSAGE DIAGNOSTICS ...
Страница 306: ...ERROR MESSAGE DIAGNOSTICS ...
Страница 307: ...O A A C t rnra g i tiw c t 3829 89 ...
Страница 308: ...RETURN TO ...
Страница 309: ...FRONT PANEL TROUBLESHOOTING ...
Страница 310: ...FRONT PANEL TROUBLESHOOTING ...
Страница 311: ...2445 Service 3829 90 ...
Страница 316: ...R E TU R N T O v 1 y ...
Страница 317: ...SWEEP TROUBLESHOOTING PROCEDURE ...
Страница 318: ...2445 Service NOTE 3 56V IS M E A S U R E D A S 1 44V W ITH R ESPEC T TO TH E 5V SUPPLY 3829 95 ...
Страница 323: ......
Страница 324: ...2445 Service 3829 85 ...
Страница 325: ......
Страница 326: ... KERNEL NOP DIAGNOSTIC PROCEDURE ...
Страница 327: ...10 POWER SUPPLY TROUBLESHOOTING PROCEDURE 3829 94 ...
Страница 330: ......
Страница 334: ...2445 Service REGULATOR TROUBLESHOOTING PROCEDURE 3829 93 ...
Страница 338: ......
Страница 346: ...12 2445 SERVICE ...
Страница 347: ...2445 SERVICE ...
Страница 348: ...2445 SERVICE ...