WCL488 Series Water Cooled Electronic Loads
Operation & Programming Manual
TDI-Dynaload Division
Page 54
402828, Rev. B1
RNG?
Read Voltage/Current Range status
Operation Modes
AV?
Read Amps/Volt setting
AVH <NR2>
Set Amps/Volt High mode
AVL <NR2>
Set Amps/Volt Low mode
CI <NR2>
Set Constant Current Mode
CI?
Read Constant Current setting
CP <NR2>
Set Constant Power mode
CP?
Read Constant Power setting
CR?
Read Constant Resistance setting
CRH <NR2>
Set Constant Resistance High mode
CRL <NR2>
Set Constant Resistance Low mode
CV <NR2>
Set Constant Voltage mode
CV?
Read Constant Voltage setting
MODE?
Read mode
XM ON
Set External Modulation on
XM OFF
Set External Modulation off
XM PLUS <NR2> Set External Modulation with programmed offset
XM + <NR2>
Alternate Syntax for XM PLUS <NR2>
XM?
Read External Modulation setting
Pulsing
DU <NR2>
Set Duty Cycle
DU?
Read Duty Cycle setting
FQ <NR2>
Set Frequency
FQ?
Read Frequency Setting
SW [<NR1>]
Set Square Wave pulsing on
SW OFF
Set Square Wave pulsing off
T1 <NR2>
Set pulse base duration
T1?
Read pulse base duration
T2 <NR2>
Set pulse peak duration
T2?
Read pulse peak duration
WF [<NR1>]
Set Square Wave pulsing on