TDI-Dynaload Division
WCL488 Series Water Cooled Electronic Loads
Operation & Programming Manual
402828, Rev. B1
Page 47
Table L. Numerical Data Units
Item
Description
Unit
Format
AV1
First resistance value (A/V mode)
Amps/Volt
Amps/Volt
AV2
Second resistance value (A/V mode)
Amps/Volt
Amps/Volt
AVH
Constant resistance setpoint
(High A/V) Amps/Volt
Amps/Volt
AVL
Constant resistance setpoint
(Low A/V) Amps/Volt
Amps/Volt
CI
Constant current setpoint
Amperes
Amps
CP
Constant power setpoint
Watts
Watts
CRH
Constant resistance setpoint
(High
Ω
) ohms
Ohms
CRL
Constant resistance setpoint
(Low
Ω
) ohms
Ohms
CV
Constant voltage setpoint
Volts
Volts
DU
Square wave duty cycle
Percent
%
FQ
Square wave frequency
Hertz
Hz
I?
Load current
Amperes
Amps
I1
First current value
Amperes
Amps
I2
Second current value
Amperes
Amps
P?
Load power
Watts
Watts
P1
First power value
Watts
Watts
P2
Second power value
Watts
Watts
R1
First resistance value (ohms mode)
Ohms
Ohms
R2
Second resistance value (ohms mode)
Ohms
Ohms
SR
Slew rate (1st and 2nd)
Microseconds
µs
T1
First duration
Microseconds
µs
T2
Second duration
Microseconds
µs
V?
Load voltage
Volts
Volts
V1
First voltage value
Volts
Volts
V2
Second voltage value
Volts
Volts
XM PLUS
(XM +)
External modulation constant current
offset
Amperes
Amps