Tandberg SLR Product Line SCSI Functional Specifications
12.4. Exception Handling
See the section on Error Conditions For All Commands.
If PCR bit is one and Parameter List Length is NOT zero
the Drive will return CHECK CONDITION status. No
parameters will be transferred, and the Error Code will
be I
NVALID FIELD IN
CDB.
If PC field is 10b or 11b and Parameter List Length is
NOT zero the Drive will return CHECK CONDITION status.
No parameters will be transferred, and the Error Code
will be I
NVALID FIELD IN
CDB.
If the Parameter List Length do not match exactly the
real length of the requested LOG-pages, the Drive will
report CHECK CONDITION status and the Error Code will be
I
NVALID FIELD IN
CDB. No log select operation will be
performed.
If any bits or bytes in the transferred parameters have
invalid values, the Drive will report CHECK CONDITION
status and the Error Code will be I
NVALID FIELD IN PARAMETER
LIST
. No log select operation will be performed.
If the parameter blocks are not transferred in an
ascending order of parameter code, the Drive will report
CHECK CONDITION status and the Error Code will be I
NVALID
FIELD IN PARAMETER LIST
. No log select operation will be
performed.
12.5. Phase Sequencing
In this section the possible SCSI-bus phase sequences
during execution of the command are described. Section
3.2.1 has more details about the generic phases in the
brackets.
<sequence 1>
:=
<initiator-part> <message-out> <command> <disconnect> <reconnect>
<data-out> <completed>
When disconnection is allowed the Drive will disconnect
when the CDB has been transferred. The Drive will
reconnect when the previous immediate command has
completed execution.
<sequence 2>
:=
<initiator-part> <message-out> <command> <data-out> <completed>
This sequence will be used when disconnection is not
allowed.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...