Mode Select
14-35
Tandberg SLR Product Line SCSI Functional Specifications
14.3.11. User Page 0
This page can be used to save any information (up to ten
bytes).
The page can be saved.
BYTE
BIT 7
6
5
4
3
2
1
0
00
PS
R
Page Code = 21h
01
Page Length = 0Ah
02
User Defined Field
03
User Defined Field
04
User Defined Field
05
User Defined Field
06
User Defined Field
07
User Defined Field
08
User Defined Field
09
User Defined Field
10
User Defined Field
11
User Defined Field
Table 14-26: User Page 0 Page Descriptor
PS
The Parameter Savable (PS) bit must be set to zero.
Page Code
The Page Code for this page must be set to 21h.
Page Length
The Page Length field must always be set to 0Ah.
User Defined Field
These fields can be used to store up to ten bytes of
user defined information.
Ö
Any value is legal (no check).
Ö
The default (factory programmed) value is 00h.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...