Tandberg Data
Log Sense
13-54
Tandberg SLR Product Line SCSI Functional Specifications
13.3.13. Cartridge Usage Page
BYTE
BIT 7
6
5
4
3
2
1
0
00
RESERVED
Page Code = 37h
01
RESERVED
02
Page Length = 36h
03
04
Cartridge Serial Number Log Parameters
17
18
Cartridge Load Counter Log Parameters
25
26
Cartridge BOT Pass Counter Log Parameters
33
34
Cartridge EOT Pass Counter Log Parameters
41
42
Cartridge Write Pass Counter Log Parameters
49
50
Cartridge Motion Time Log Parameters
57
Table 13-51: Cartridge Usage Page
Page Code
The Page Code for this page is 37h.
Page Length
This field is always set to 36h indicating that the page
parameters occupy 54 bytes.