Tandberg Data
Log Sense
13-60
Tandberg SLR Product Line SCSI Functional Specifications
Cartridge Write Pass Counter Log Parameters
BYTE
BIT 7
6
5
4
3
2
1
0
n+0
n+1
Parameter Code = 0005h
n+2
DU
DS
TSD
ETC
TMC
LBIN
LP
n+3
Parameter Length = 04h
n+4
Cartridge Write Pass Counter
n+7
Table 13-56: Cartridge Write Pass Counter Log Parameters
Parameter Code
The Parameter Code is set to 0005h.
DU
The Disable Update (DU) bit is not defined for List
Parameters (indicated by the LP bit) and is set to 0.
(Note: This bit can not be changed by the initiator)
DS
The Disable Save (DS) bit is set to 1 to indicate that
the Drive does not support saving of this log parameter
in response to a LOG SELECT or LOG SENSE command with an
SP bit of 1.
(Note: This bit can not be changed by the initiator)
TSD
The Target Save Disable (TSD) bit is set to 0. The Drive
will save this list parameter on the medium for each
write operation.
(Note: This bit can not be changed by the initiator)
ETC
The Enable Threshold Comparison (ETC) bit is not defined
for List Parameters (indicated by the LP bit) and is set
to 0.
(Note: This bit can not be changed by the initiator)
TMC
The Threshold Met Criteria (TMC) field is not defined
for List Parameters (indicated by the LP bit) and is set
to 0.
(Note: This bit can not be changed by the initiator)
LBIN
The LBIN bit is set to 1 to indicate that the List Pa-
rameter contains binary information.
(Note: This bit can not be changed by the initiator)
LP
The List Parameters (LP) bit is set to 1 to indicate
that the parameter is a List Parameter.
(Note: This bit can not be changed by the initiator)
Parameter Length
This field is set to 04h to indicate that the counter is
4 bytes wide.
Cartridge Write
Pass Counter
The Write Pass Counter is incremented each time the
medium is written from BOP. Each partition has a
separate Write Pass Counter and this page will return
the counter of the current partition.
Any attempt by initiator to alter this parameter value
will be ignored.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...