Tandberg Data
Read
17-9
Tandberg SLR Product Line SCSI Functional Specifications
17.4. Phase Sequencing
In this section the possible SCSI-bus phase sequences
during execution of the command are described. Section
3.2.1 has more details about the generic phases in the
brackets.
<sequence 1>
:=
<initiator-part> <message-out> <command> <disconnect> <reconnect>
<completed>
This sequence will be used when an error is detected
during the initial part of the READ command or when the
Transfer Length is zero.
<sequence 2>
:=
<initiator-part> <message-out> <command> {<disconnect>
<reconnect> <data-in>} <completed>
This sequence will be used when the READ command
terminates with GOOD STATUS.
The Drive will first disconnect when the CDB has been
transferred. The Drive will reconnect when the number of
bytes ready for transfer is equal or larger than the
Read Buffer Full Ratio. The Drive will disconnect to
make sure that the burst size never exceeds the number
of bytes specified by the Maximum Burst Size. The Drive
will not disconnect after the last data burst.
<sequence 3>
:=
<initiator-part> <message-out> <command>{<disconnect> <reconnect>
<data-in>}<disconnect> <reconnect> <completed>
This sequence will be used when an error is encountered
during the READ operation.
The sequence is equal to <sequence 2> except that the
Drive will disconnect before sending status.
<sequence 4>
:=
<initiator-part> <message-out> <command> {<data-in>} <completed>
This sequence will be used when the READ command is
executed and the Initiator does not allow disconnection.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...