Tandberg Data
General Exception Handling
7-2
Tandberg SLR Product Line SCSI Functional Specifications
Error code table sorted by name.
The same table sorted by AS/AQ code is located in Section 23.5.
Name
AS
AQ
SK
FMK
EOM
ILI
ERAC
B
EGINNING
-
OF
-
PARTITION
/
MEDIUM DETECTED
00h
04h
0h
■
5
C
ANNOT DECOMPRESS USING THE DECLARED ALGORITHM
11h
0Eh
3h
5
C
ANNOT FORMAT MEDIUM
,
INCOMPATIBLE MEDIUM
30h
06h
5h
2
C
ANNOT
R
EAD
M
EDIUM
, I
NCOMPATIBLE
F
ORMAT
30h
02h
3h
2
C
ANNOT READ MEDIUM
-
UNKNOWN FORMAT
30h
01h
3h
2
C
ARTRIDGE FAULT
, B
AD
C
ARTRIDGE
52h
00h
3h
2
C
ARTRIDGE FAULT
, R
EFERENCE
B
URST
S
EEK
F
AILURE
52h
00h
3h
1
C
LEANING
C
ARTRIDGE
E
JECTED
82h
83h
6h
4
C
LEANING CARTRIDGE INSTALLED
30h
03h
2h
2
C
LEANING
F
AILURE
30h
07h
3h
2
C
LEANING REQUESTED
00h
17h
1h
1
C
OMMAND SEQUENCE ERROR
2Ch
00h
5h
5
D
ATA EXPANSION OCCURRED DURING COMPRESSION
0Ch
05h
1h
5
D
ECOMPRESSION
CRC
ERROR
11h
0Dh
3h
5
D
IAGNOSTIC FAILURE IN SELFTEST
N
1
40h
nnh
2
4h
6
D
IAGNOSTIC FAILURE
, B
UFFER
P
ARITY
E
RROR
40h
80h
4h
3
D
IAGNOSTIC
F
AILURE
, W
RITE
C
HIP
E
RROR
40h
81h
4h
6
D
IAGNOSTIC FAILURE
,
MULTIPLE ERRORS
40h
A0h
4h
6
E
ND
-
OF
-
DATA DETECTED
00h
05h
8h
5
E
ND
-
OF
-
DATA DETECTED AFTER
LEW
00h
05h
8h
■
5
E
ND
-
OF
-
PARTITION
/
MEDIUM DETECTED ON READ
,
PHYSICAL END REACHED
00h
02h
3h
■
5
E
ND
-
OF
-
PARTITION
/
MEDIUM DETECTED ON WRITE
, LEW
PASSED
00h
02h
0h
■
0
E
ND
-
OF
-
PARTITION
/
MEDIUM DETECTED ON WRITE
,
PHYSICAL END REACHED
00h
02h
Dh
■
0
E
RASE FAILURE
51h
00h
3h
3
E
XCESSIVE WRITE ERRORS
03h
02h
3h
1
E
XCESSIVE WRITE ERRORS
(S
ERVO
)
03h
02h
3h
2
F
ILEMARK DETECTED
00h
01h
0h
■
5
I
NCOMPATIBLE MEDIUM INSTALLED
30h
00h
5h
2
I
NITIATOR DETECTED ERROR MESSAGE RECEIVED
48h
00h
Bh
5
I
NTERNAL TARGET FAILURE
44h
00h
4h
6
I
NVALID BITS IN
IDENTIFY
MESSAGE
3Dh
00h
5h
5
I
NVALID COMMAND OPERATION CODE
20h
00h
5h
5
I
NVALID FIELD IN
CDB
24h
00h
5h
5
I
NVALID FIELD IN PARAMETER LIST
26h
00h
5h
5
L
OG COUNTER AT MAXIMUM
5Bh
02h
1h
4
Table 7-1: Error Codes (to be continued…)
1
N is a number in the range 1 to 40 inclusive.
2
nn is a hex number in the range A1h to C8h inclusive. A1h corresponds
to a diagnostic failure in selftest 1, A2h corresponds to a
diagnostic failure in selftest 2 and so on up to C8h which
corresponds to a diagnostic failure in selftest 40.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...