Tandberg Data
Log Sense
13-37
Tandberg SLR Product Line SCSI Functional Specifications
TSD
The Target Save Disable (TSD) bit is set to 1 to
indicate that the Drive does not provide any Drive-
defined method for saving of this log parameter.
(Note: This bit can not be changed by the initiator)
ETC
The Enable Threshold (ETC) bit is set to 0 to indicate
that no threshold comparison will take place.
TMC
The Threshold Met Criteria (TMC) field is valid only if
ETC bit is 1 and it selects one of four possible
Threshold Met Criteria.
The default value is 11b. See the LOG SELECT command for
further description.
LP
The List Parameters (LP) bit is set to 0 to indicate
that the parameter is a data counter.
(Note: This bit can not be changed by the initiator)
Parameter Length
This field is set to 04h to indicate that the counter is
4 bytes wide.
Filemark Counter
This counter counts the number of filemarks received
from or reported to the Initiator, and number of
filemarks being spaced over on Initiators request (i.e.
SCSI commands: Space over filemarks and Space over
sequential filemarks)
1
.
1
The counter always counts up without regard to the direction of the
space command.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...