![Tandberg Data SLR7-140 PROGRAMMER Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/tandberg-data/slr7-140-programmer/slr7-140-programmer_manual_3496838096.webp)
Tandberg Data
Message System
6-11
Tandberg SLR Product Line SCSI Functional Specifications
6.4.
Message Reject Message Handling
This section specifies the use of the MESSAGE REJECT
message in both message-in and message-out phases.
6.4.1.
Message-In Phase
The drive sends a MESSAGE REJECT message in the
following instances:
When an unsupported message has been received from
the Initiator. Supported messages are shown in table
6-2.
When a MESSAGE REJECT message has been received after
a phase that was not a message-in phase.
6.4.2. Message-Out
Phase
If, after a MESSAGE-IN phase, the Initiator asserts ATN
and transfers a REJECT message, the Drive will react as
shown in the table below:
Last Message-In
Action Taken
DISCONNECT
The Drive will not disconnect any more until an IDENTIFY message with the
Disconnect Privilege bit set to one is received.
IDENTIFY
The current command is terminated and the drive goes to BUS FREE.
IGNORE WIDE RESIDUE
The reject is ignored and the current command continues execution.
LINKED COMMAND
COMPLETE
The current command is terminated and the drive goes to BUS FREE.
LINKED COMMAND
COMPLETE W/FLAG
The current command is terminated and the drive goes to BUS FREE.
MESSAGE REJECT
The reject is ignored and the current command continues execution.
SAVE DATA POINTER
Same as for a DISCONNECT message.
SYNCHRONOUS DATA
TRANSFER REQUEST
The Drive goes back to asynchronous data transfer.
TASK COMPLETE
Ignore the REJECT message (the drive goes to BUS FREE).
WIDE DATA TRANSFER
REQUEST
The Drive goes back to 8-bit data transfer.
Table 6-8: Response to MESSAGE REJECT
If the MESSAGE REJECT message is sent following phases
other than MESSAGE-IN, the Drive will respond by sending
a MESSAGE REJECT message.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...