General Exception Handling
7-13
Tandberg SLR Product Line SCSI Functional Specifications
7.9.
Suggested Error Recovery Action
For each error code in table 7-1 a suggested error
recovery action code (ERAC) is listed. The ERAC code is
meant to indicate a suitable recovery action to be taken
by the Initiator or the system operator when an error
has occurred. The different recovery actions are:
0 :
No action
1 :
Clean drive. Drive needs cleaning. Use a cleaning
cartridge.
2 :
Try another cartridge. The cartridge is questionable
and should be replaced.
3 :
Run diagnostics. A possible hardware problem. Execute
a SEND DIAGNOSTICS command, a Self-exerciser selftest
or run a Diagnostic tape to get more information.
4 :
Re-issue command. A temporary condition (for instance
a Unit Attention) needs to be cleared.
5 :
Re-issue corrected command and/or parameter list. The
drive detected an error in the CDB or in a parameter
list. A reserved bit or field that is not set to zero
or a field value that is out of range typically
causes this.
6 :
Call service. The drive has detected a hardware
problem. To be correct by authorized service
personnel.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...