Tandberg SLR Product Line SCSI Functional Specifications
2.11. TapeAlert
The TapeAlert information is accessed via LOG SENSE page
2Eh (see section 13.3.5 TapeAlert Page), and
configuration is done via MODE SELECT page 1Ch (see
section 14.3.9 Informational Exceptions Control Page).
The Mode Sense/Select configuration of the TapeAlert
interface is compatible with the SMART diagnostic
standard for disc drives. The host software should first
check the tape drive to determine whether it supports
the TapeAlert Log Sense page 2Eh. By default the host
software access to the TapeAlert Log Sense page is via
polling.
The TapeAlert Log Sense page shall be read from a tape
drive device at the following times as a minimum:
At the beginning of a write/read job, even if media
is not loaded.
Immediately after a fatal error during the
write/read job.
At the end of each tape when the write/read job
spans multiple tapes. If the tape is to be ejected
then the Log Sense page must be read BEFORE this.
At the end of a write/read job.
Though not mandatory, the host software may also poll
the Log Sense page at regular intervals (e.g. every 60
seconds) while the tape drive is idle.
The TapeAlert Log page contains 64 one-byte alert flags.
The specific conditions for any one flag to be set and
cleared are defined in section 13.3.5.
There are three flag severity levels, listed below in
order of severity:
Critical
(C)
Warning
(W)
Information
(I)
Each time the host software reads the TapeAlert Log
page, it should check all 64 flags to discover which are
set (there may be more than one). The definitions of the
64 flags are device type specific, so that there is one
definition for tape drive devices, and a different
definition for stand-alone changer devices (in
libraries). For each flag that is set, the host software
shall communicate the defined error message and severity
for that flag to the user, and also log it. If multiple
flags are set simultaneously, they will be displayed
together in ascending order of severity. At the
beginning of each set of TapeAlert error messages, the
tape device that initiated them must be identified. For
the tape drive media-related flags (flags 4, 7 and 14)
the software label of the media, if such exist, should
be included in the TapeAlert error messages so that the
user is aware what piece of media the error refers to.
Such information could also be displayed with the
messages for other flags as well if required. The
information read in the TapeAlert flags should not in
itself cause the software to stop a current
backup/restore job.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...