15-1
Tandberg SLR Product Line SCSI Functional Specifications
15.
Mode Sense
15.1. Command Description
The MODE SENSE command provides a means for the Drive to
report parameters to the Initiator. It is a
complementary command to the MODE SELECT command.
The Drive will implement only one common set of
parameters for all Initiators.
The MODE SENSE parameter list will be returned during
the DATA IN phase of the command.
When page format is used the MODE SENSE command may
return 4 different types of parameters; current values,
changeable values, default values or saved values.
Current Values
The current values are the values under which the Drive
is presently configured for the page specified. The
current values returned are:
1)
The parameters set in the last successful MODE SELECT
command.
2)
The saved values if a MODE SELECT command has not
been executed since the last power-up, RESET
condition or TARGET RESET message.
3)
The factory saved values if a MODE SELECT command has
never been executed with the save parameter (SP) bit
set.
Changeable Values
The page requested will be returned containing
information that indicates which fields are changeable.
Parameters that are changeable will be set to one.
Parameters that are not changeable will be set to zero.
If any part of a field is changeable all bits in that
field will be set to one. If none of the parameters are
changeable within a page, the Page Length value will be
set to zero.
Default Values
The default values are set once and for all in the
Drive's production line. Parameters not supported by the
Drive will be set to zero.
Saved Values
The saved values are the values saved by the last
successful MODE SELECT command with the save parameter
(SP) set or the default values if no MODE SELECT with
the SP bit has never been executed. Saved values are
located in the EEPROM. Parameters not supported by the
Drive will be set to zero.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...