Tandberg Data
Receive Diagnostic Results
21-6
Tandberg SLR Product Line SCSI Functional Specifications
21.4. Results From the Stand Alone
Diagnostics Test
When the Page Code is set to 98h, the analysis data returned will be from the last
completed Stand Alone Diagnostics test.
The results from the Stand Alone Diagnostic survives
Reset/Power On. See the Reference Manual for details
about the Stand Alone Diagnostic test.
21.4.1. The Stand Alone Diagnostic Result Page
BYTE
BIT 7
6
5
4
3
2
1
0
00
Page Code
01
RESERVED
02
Page Length
03
04
First failing AID no.
05
Result from the last SAD
06
Tape format
07
RESERVED
08
Time Stamp for last completed SAD
09
10
11
12
Current Time Stamp
13
14
15
Table 21-5: The Stand Alone Diagnostic Page
Page Code
This field is always set to 98h.
Page Length
This field specifies the length in bytes of the analysis
data that follow this field. The Page Length will have a
value of 12.
First failing AID
no.
If the last completed Stand Alone Diagnostics test has
failed, this field will be set to the first failing
Activity Id (AID) number.
If the last Stand Alone Diagnostics test has been
successfully completed, this field will be set to FFh.
Result from the
last SAD
This field is set to the test result for the last
completed Stand Alone Diagnostics test. This field can
have the following values:
00h: Stand Alone Diagnostics test successfully
completed.
01h: Stand Alone Diagnostics test has failed.
Tape format
This field is set to the tape format in the last
completed Stand Alone Diagnostics test.
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...