Tandberg Data
Mode Select
14-34
Tandberg SLR Product Line SCSI Functional Specifications
Bus Parity Error
Retries
This field is used to specify the maximum number of
consecutive retries of information transfer upon
detection of parity error on the data bus or reception
of an INITIATOR DETECTED ERROR message for the same
bus phase.
Ö
Legal values are 0..255, where 0 indicates that there
should be no retries and where a value of 255
indicates that there is no limit to the number of
retries attempted (the retry sequence must be
terminated by the Initiator).
Ö
The default (factory programmed) value is 4
Reselection
Retries
This field is used to specify the maximum number of
reselection retries when the Drive is trying to
reconnect to the Host. If the number of retries is
exceeded, the command will be aborted..
Ö
Legal values are any number in the range 0..255,
where values in the range 0..254 indicate a limited
number of reselection attempts and the value 255
indicates an infinite number of reselection retries.
Ö
The default (factory programmed) value is 4
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...