![Tandberg Data SLR7-140 PROGRAMMER Скачать руководство пользователя страница 174](http://html1.mh-extra.com/html/tandberg-data/slr7-140-programmer/slr7-140-programmer_manual_3496838174.webp)
Tandberg Data
Log Sense
13-27
Tandberg SLR Product Line SCSI Functional Specifications
Write Media Block Counter Log Parameters
BYTE
BIT 7
6
5
4
3
2
1
0
n+0
n+1
Parameter Code = 0001h
n+2
DU
DS
TSD
ETC
TMC
R
LP
n+3
Parameter Length = 08h
n+4
Write Media Blocks Counter
n+11
Table 13-26: Write Media Blocks Counter Parameters
Parameter Code
The Parameter Code is set to 0001h.
DU
A Disable Update (DU) bit set to 0 indicates that the
Drive is free to update the counter.
A DU bit set to 1 indicates that the Drive shall not
update the counter except in response to a LOG SELECT
command that specifies a new value for the counter.
The initiator may use the LOG SELECT command to set or
clear the DU bit.
The Drive sets the DU bit to 1 when the counter reaches
its maximum value (FFFFFFFFFFFFFFFFh).
DS
The Disable Save (DS) bit is set to 0 to indicate that
the Drive does support saving of this log parameter.
(Note: This bit can not be changed by the initiator)
TSD
The Target Save Disable (TSD) bit is set to 0. The Drive
will save this log parameter each time a cartridge is
unloaded.
(Note: This bit can not be changed by the initiator)
ETC
An Enable Threshold Comparison (ETC) bit indicates
whether comparison to the threshold value is performed
or not.
The default value is 0. See the LOG SELECT command for
further description.
TMC
The Threshold Met Criteria (TMC) field is valid only if
ETC bit is 1 and it selects one of four possible
Threshold Met Criteria.
The default value is 11b. See the LOG SELECT command for
further description.
LP
The List Parameters (LP) bit is set to 0 to indicate
that the parameter is a data counter.
(Note: This bit can not be changed by the initiator)
Parameter Length
This field is set to 08h to indicate that the counter is
8 bytes wide.
Write Media Blocks
Counter
This counter counts the physical blocks, written to the
media, during write operations. It is incremented by one
on the detection of each new physical block. (The
physical blocks are data blocks, control blocks, filler
blocks, ECC blocks and tape marks.)
Содержание SLR7-140 PROGRAMMER
Страница 140: ...Tandberg Data Locate 11 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 282: ...Tandberg Data Read 17 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 334: ...Tandberg Data Space 27 8 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 340: ...Tandberg Data Verify 29 4 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...
Страница 350: ...Tandberg Data Write 30 10 Tandberg SLR Product Line SCSI Functional Specifications This Page Intentionally Left Blank...