Tandberg Data
Chapter 4 - Configuration
SCSI Options
Loader SCSI ID
— Sets the SCSI ID of the loader. Legal values range from 0 –
15
.
Drive SCSI ID
—
Sets the SCSI ID of the drive. Legal values range from 0 – 15
.
Loader Parity
—
Enables/Disables the parity checking for the loader SCSI bus
.
Vendor ID
— Sets the SCSI Vendor ID. The default Vendor ID is “Tandberg
Data”. Other predefined Vendor ID’s can be selected by scrolling through a list of
choices or enter a unique string by selecting the <Vendor Unique> setting.
Product ID
— Sets the SCSI Product ID. The default selection for this option is
SLR Autoloader. Other predefined Product IDs can be selected by scrolling through
a list, or entering a unique string after selecting the <Product Unique> setting.
Negotiation Mode
— Determines if SCSI negotiation is initiated by the loader.
Allowable values are Do Not Initiate or Initiate.
Transfer Rate
— Defines the SCSI burst transfer rate. Allowable values are:
•
Synchronous, 10 MB/sec
•
Synchronous, 5 MB/sec
•
Asynchronous Only.
Mode Pg 1F Length
— Defines the length of the Device Capabilities page
Parameter Length expected by a SCSI Host.
TUR Reporting
— Determines how the loader should respond to a Test Unit
Ready command if in Sequential Mode. This option is available only if sequential
mode is active.
Init Elem Status
— Determines how the loader should respond to an Initialize
Element Status command. The options are:
•
No Inventory
•
Force Inventory
•
Force Label Scan.
Unit Attn Report
— Determines if the loader should stack multiple Unit Attention
responses (ALL) or send only the highest priority Unit Attention response (One).
SCSI Mode
— Defines the loader as SCSI-2 or SCSI-3.
Tandberg SLR Autoloader Service and Repair Manual
45