Y-8
Y-8
Operation Check (Crane Operation)
47
WY05-2492E
4. Boom telescoping control
[Boom length: 5.3 - 23.8 m (17.4 - 78 ft)]
CN503: 4th/top boom emergency telescoping switch
CN504: 2nd/3rd boom emergency telescoping switch
CN506: 4th/top boom extending switch
CN859: 4th/top boom full retraction detection switch
CN553: 2nd/3rd boom full retraction detection switch
4.1 Extension
4.2 Retraction
5.3 m (17.4 ft) boom (base)
Telescoping is possible only
for 2nd and 3rd boom.
Boom length: 12.5 m (41.0 ft)
CN506 switch: OFF
2nd and 3rd boom can be moved to the
stroke ends.
(AML works on the basis of performance
with the 3rd shortest boom.)
CN506 switch: ON
Extension of 4th to top boom is possible.
(When CN859 switch turns OFF, AML begins to
work on the basis of performance with the 4th
shortest boom.)
Approximately 16.4 m (53.8 ft) boom
(4th shortest)
4th to top boom retract.
CN859 switch: ON
2nd and 3rd boom retracts.
(Even if stroke remains for the 4th to top
boom at this time, the hydraulic valve orifice
causes them to retract fully.)