Y-5
Y-5
Adjusting Procedure (Electric)
32
WY04-2470E
4. Jib connection pin detection switch
(CN549)
1. Change the installing position of the detector
switch roller lever as shown in the figure below.
2. Apply thread locking agent (ThreeBond 1401 or
equivalent) to the threaded section of the detector
switch.
3. Stow the jib.
4. Make sure that the detector switch works when
the connection pin is inserted.
Switch fixing bolt tightening torque:
4.9 to 5.9 N-m (50 to 60 kgf-cm) (3.6 to 4.3 ft-lbf)
△
5
343-537-92000