TAC 2112, Manual
Commissioning Protocol / List of Parameters
TAC AB, 1999-08-01
0-004-7459-3 (GB), A:3(6)
P No. Parameter
Min.
Max.
Step
Default
Change Comments
P 37
Max heating time
0 h
24 h
1 h
6 h
h=hours. See curve.
P 38
Heating time, –10 °C (y0)
0 m.
1440 m. 1 m.
120 m.
Changed by ctrl. if P 35=1
P 39
Heating time, +10 °C (y1)
0 m.
1440 m. 1 m.
20 m.
Changed by ctrl. if P 35=1
20
120
-10
0
5
-5
10
15
20
-15
25
-20
-25
P 38
P 37
y0
(minutes)
Heating time
y1
P 39
Damped
360
P 40
% Monday effect
0%
50%
1%
10%
Changed by ctrl. if P 35=1
P 41
Opt. time at –10 °C (y0)
0 m.
240 m.
1 m.
0 m.
Reduced daytime op.
P 42
Opt. time at +10 °C (y1)
0 m.
240 m.
1 m.
0 m.
Reduced daytime op.
10
30
-10
0
5
-5
10 15 20
-15
25
-20
-25
P 41
y1
in the room (minutes)
per degree of excess temp.
y0
P 42
Reduced daytime operation
Damped
show default settings
N.B. The figure does not
P 43
Return limitation on/off
0
2
1
0 (off)
0
=off, 1=on
P 44
Return limit. heat., P band
10 °C
200 °C
0,5 °C
20 °C
Not if P 43=0
P 45
Curve point x0
–30 °C
P 47
1 °C
–10 °C
Not if P 43=0. See curve
P 46
Curve point y0
P 48
120
°C
1 °C
70 °C
Not if P 43=0. See curve
P 47
Curve point x1
P 45
40 °C
1 °C
10 °C
Not if P 43=0. See curve
P 48
Curve point y1
10°C
P 46
1 °C
40 °C
Not if P 43=0. See curve
30
40
50
60
70
80
-10
0
5
-5
10 15 20
-15
25
-20
-25
x1
y0
y1
P 46
P 47
P 48
P 45
x0
Damped
P 49
Содержание 2112
Страница 1: ...TAC 2112 Manual 0 004 7459 3 GB 1999 08 01 T1 P1...
Страница 2: ......
Страница 62: ...TAC 2112 Manual Commissioning Protocol List of Parameters A 6 6 0 004 7459 3 GB 1999 08 01 TAC AB...
Страница 66: ...TAC 2112 Manual Index Index 4 4 0 004 7459 3 GB TAC AB 1999 08 01...
Страница 68: ...TAC 2112 Manual Reply form 1999 08 01 TAC AB...
Страница 69: ......
Страница 70: ...TAC AB J gershillgatan 18 SE 213 75 MALM SWEDEN 46 40 38 68 50 www tac se...