098-00564-000 Revision A3 – July, 2013
TimeProvider 2300/2700 User’s Guide
247
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
2. Type
show input status t1e1
and press
Enter
.
– Verify that IO status matches the configured setting.
– Verify that the input status is “OK”.
------------------------------------------------------------------------|
| Port | io status | input status | ssm | los | ais | oof | bpv | crc |
|------|-----------|--------------|-------|-----|-----|-----|-----|-----|
| t1e1 | e1 input | ok | ok | ok | ok | ok | ok | ok |
|.......................................................................|
or
------------------------------------------------------------------------------
|Port |input status|ssm |los |ais |oof |bpv |crc |
|---------|------------|--------|--------|--------|--------|--------|--------|
|t1 input |dis |na |na |na |na |na |na |
------------------------------------------------------------------------------
3. Use the procedure
, on page 239 to check the reference
configuration and status.
Output
1. Type
show output config t1e1
and press
Enter
.
– Verify that the Output Configuration settings match the desired values.
– Verify that the IO Direction is “Output”.
– Verify that the Port State is “enable”.
– Verify that the Signal/Format is set to the desired value.
tp2700> show output config t1e1
Output Config
--------------------------------------------------------------
|Signal |FrameType |CRC |SSMBit |zero suppression|
|------------|------------|--------|--------|----------------|
|e1 output |ccs |enable |all |off |
|............|............|........|........|................|
|t1 output |esf |na |na |na |
--------------------------------------------------------------
Port Config
--------------------------------------------------------
|Port |state |io dir |Signal /Format |
|------------|------------|------------|---------------|
|t1e1 |enable |input |e1 |
--------------------------------------------------------