206
TimeProvider 2300/2700 User’s Guide
098-00564-000 Revision A3 – July, 2013
Chapter 4 Provisioning
Provisioning Input Parameters
6. Type
set ptp client config eth1 telecom-2008 lease-duration 300
and
press
Enter
.
7. Type
set ptp client config eth1 telecom-2008 announce-interval 1
and press
Enter
.
8. Type
set ptp client config eth1 telecom-2008 sync-interval -6
and
press
Enter
.
9. Type
set ptp client config eth1 telecom-2008 delay-req-interval -6
and press
Enter
.
10.Type
set ptp client config eth1 telecom-2008 domain 5
and press
Enter
.
11.Type
set ptp client config eth1 telecom-2008 master-table add
index 1 address 192.168.5.100
and press
Enter
.
12.Type
set ptp client config eth1 transport ethernet
and press
Enter
.
13.Type
set ptp client config eth1 service-tier traffic_mask
and press
Enter
.
Setting GNSS Parameters
When the GNSS reference is enabled, you can set the satellite position parameters
either automatically or manually. The GNSS reference input is enabled by default.
In manual mode, you must specify the latitude, longitude, and height. Manual mode
should not be used unless antenna location has been accurately surveyed. See the
command description for details about setting GNSS position parameters
manually.
You can specify the elevation mask which filters the satellites used by the system.
You can also specify the cable delay.
Note:
It is important the cable delay be configured with the proper
value. This can be determined from the cable length.