098-00564-000 Revision A3 – July, 2013
TimeProvider 2300/2700 User’s Guide
153
Chapter 3
TimeProvider 2300/2700 CLI Command Set
TP2700> show ref status
Response 2:
Time Reference Status
------------------------------------
|Reference |final-pql|status |
|----------|---------|-------------|
|GNSS |1 |disqualified |
|..........|.........|.............|
|PTP |3 |selected |
------------------------------------
Frequency Reference Status
------------------------------------
|Reference |final-pql|status |
|----------|---------|-------------|
|GNSS |1 |disqualified |
|..........|.........|.............|
|PTP |3 |selected |
|..........|.........|.............|
|SYNCE |3 |qualified |
|..........|.........|.............|
|T1E1 |16 |disqualified |
------------------------------------
Level :
User, Config, and Admin
set ref
Use this command to provision the system's reference port(s) priority, configured
quality Level (PQL), reference selection criteria, and reference switching mode.
The Timing References includes GNSS (GPS/GLONASS), and PTP (with PTP
timescale) inputs.
The frequency references includes GNSS, T1/E1, SyncE and PTP inputs.
Command Syntax:
To set the priority for a time reference input:
set ref time priority {gnss | ptp} {1 - 10}
To set the config-PQL value for a time reference input:
set ref time config-pql {gnss | ptp} {1 - 16}