098-00564-000 Revision A3 – July, 2013
TimeProvider 2300/2700 User’s Guide
245
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
Time Scale : PTP
Time Source : GPS
Time Traceable : true
Frequency Traceable : true
Steps Removed : 1
3. Use the procedure
, on page 239 to check the reference
configuration and status.
Verifying SyncE Functionality
Input
1. Type
show synce config all
and press
Enter
.
SyncE Config:
----------------------------
|Port |State |QL State|
|------|----------|--------|
|eth1 |enable |enable |
|......|..........|........|
|eth2 |enable |enable |
----------------------------
2. Type
show synce status all
and press
Enter
.
– Verify that the Ethernet Mode is “synchronous”.
– Verify that the RxSSM value for ETH1 port is consistent with the quality
needed for your network.
-------------------------------------------------------
|Port |Direction |Ethernet Mode |RxSSM |TxSSM |
|--------|----------|---------------|--------|--------|
|eth1 |input |synchronous |0x02 |0x0f |
|........|..........|...............|........|........|
|eth2 |output |synchronous |0xff |0x02 |
-------------------------------------------------------
3. Use the procedure
, on page 239 to check the reference
configuration and status.
Output
1. Type
show synce config all
and press
Enter
.
SyncE Config: