222
TimeProvider 2300/2700 User’s Guide
098-00564-000 Revision A3 – July, 2013
Chapter 4 Provisioning
Provisioning the Non-PTP Outputs
Figure 4-21. Set Output Command Hierarchy
The SSM function is supported for the frame types CCS, CAS, and ESF. However,
the SSM-bit parameter only applies to the E1 frame types, CCS and CAS. If the
output frame type supports SSM and SSM is enabled for the output port, then the
output signal will contain the system SSM value.
Provisioning T1 Output
Use the following procedure to provision the T1/E1 port as a T1 output:
Example:
To provision TI/E1 port as a T1 output port with a frametype of D4 and to enable the
port:
1. Login at the Admin or Config-user level.
2. Type
set port-control t1e1 io output
and press
Enter
.
3. Type
set port-control t1e1 signal-type t1
and press
Enter
.
4. Type
set output t1 frametype t1e1 d4
and press
Enter
.
5. Type
set port-control t1e1 state enable
and press
Enter
.
Provisioning E1 Output
Use the following procedures to provision the T1/E1 port as a E1 output: