098-00564-000 Revision A3 – July, 2013
TimeProvider 2300/2700 User’s Guide
211
Chapter 4 Provisioning
Provisioning Input Parameters
4. Type
set input t1 frametype t1e1 freq1544khz
and press
Enter
.
5. Type
set port-control t1e1 state enable
and press
Enter
.
Provisioning E1 Input
Use the following procedure to provision the T1/E1 port as a E1 input:
Example:
To provision TI/E1 port for an E1 output with a frametype of CCS, CRC enabled,
SSM bit of 7, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set port-control t1e1 io input
and press
Enter
.
3. Type
set port-control t1e1 signal-type e1
and press
Enter
.
4. Type
set input e1 frametype t1e1 ccs
and press
Enter
.
5. Type
set input e1 crc t1e1 enable
and press
Enter
.
6. Type
set input e1 ssmbit t1e1 7
and press
Enter
.
7. Type
set port-control t1e1 state enable
and press
Enter
.
Note:
Disabling the input port will clear all alarms and events related
to this port.