CHAPTER FIVE - ADVANCED PROGRAMMING
62
SG-Sys
tem I Operating Man
ual
5
Program Operation:
For example: "01-002-1234-A4-".
SG-DRL3 Option 71: Library Select
SG-DRL3-2L Option 171/271: Library Select
Default (04)
Determines how to use Printer Words Options.
00 No printer words.
01 Printer words options used for 1-digit reporting code formats only; other will use pre-defined library.
02 Printer words options used for 2-digit reporting code formats only; other will use pre-defined library.
03 Printer words options used for 3-digit reporting code formats only; other will use pre-defined library.
04 Printer words options used for 1-digit and 2-digit reporting code formats only; other will use pre-defined library.
05 Printer words options used for 1-digit, 2-digit and 3-digit reporting code formats.
NOTE: Option 71 is ignored when using SIA, ITI, Contact-ID, ACRON, MODEM II, MODEM IIE, MODEM IIIa², FBI
SuperFast, BFSK, ADEMCO Super Fast and SK FSK1, 2 formats.
SG-DRL3 Option 72: SIA Option
SG-DRL3-2L Option 172/272: SIA Option
Default 00000000
This option is a bit selectable Option meaning some or all of these choices may be enabled. For example, to enable "Force SIA Zone Num-
ber", and "Convert Pulse formats to SIA", set Option 72/172/272=05. To enable only "Convert Pulse to SIA" and "Convert BFSK to SIA" set
Option72=0C.
Bit 0 - Force SIA Zone Number.
The receiver will decode SIA Alarms sent without Zone numbers and add '00' as the zone number to the automation output:
Example: [#1234|NriBA] becomes [#1234|NriBA00]
Example: [#1234|NBA/BH] become [#1234|NBA00/BH00]
Bit 1 - Convert SIA Account A's.
Any Account Digits received as 'A' will be converted to '0'.
Example: [#A123|NriBA01] becomes [#0123|NriBA01]
Bit 2 - Convert Pulse formats to SIA.
All Pulse Format Printer and Computer outputs will be converted to a SIA format, in a two step conversion process.
The automation Output will use the Protocol ID of 'R'.
First the type of alarm is determined by Options 30/130/230-5F/15F/25F, 70/170/270.
Secondly the type of alarm is mapped to a SIA output as per the following table.
Setting
Description
00
Use individual event codes to computer.
20, 30-39
& 41-5A
Use common event codes (space, 0-9, A-Z). When using common event codes, Sur-Gard
recommends that either hexadecimal code '5A' (ASCII 'Z') or hexadecimal code '41'
(ASCII 'A') be used. The 'Space' character (Hex 20) can be used as the common event
code with certain automation software packages to avoid account code database changes
when switching over from other brand receivers to the Sur-Gard receiver.
B0-DF
('0'-'9', 'A'-'Z' with the most significant bit set). This range will function in the same way
as 30-39, 41-5A, with the exception that, for the Superfast Ademco Format, the Printer
Message text will not be output.
Содержание SG-System III
Страница 22: ...Line Card In This Chapter Standby Mode on page 19 Line Fault on page 21...
Страница 92: ...In this Chapter Options 00 47 on page 90 SG DRL3 IP Programming...
Страница 100: ...Printer Words...
Страница 105: ...Telco Connector Pin Outs...
Страница 107: ...DEC HEX BIN Conversion Chart...
Страница 109: ...ASCII Character Chart...
Страница 111: ...SG DRL3 SG DRL3E SG DRL3 2L Communication Formats...
Страница 113: ...Ports...
Страница 115: ...Events Messages...
Страница 124: ...Glossary...