CHAPTER FOUR - PROGRAMMING/OPERATION
31
SG-Sys
tem I Operating Man
ual
4
Option 0D: Serial Parity
Default (0)
Determines the parity of serial port 2.
NOTE: The number of stop bits can not be changed and will always be 2.
NOTE: For changes to this program option a reset of the unit is required before the new parameters are used.
Option 0E: AHS Operation Options
Default (24) (disabled)
This option is used to program the time at which the AHS table will be saved to flash memory. Valid entries for this section are from 00 (12
AM) to 23 (11 PM) - and 24 (disabled).
Primary and Secondary SG-CPM3 must have this option programmed with the same value.
New and Modified AHS entries that are automatically generated by new incoming calls to line cards will be added to the backup CPM3
automatically via port 1030. This operation will happen every 5 minutes. At this time all entries that are new/modified will be synchronized
with the other CPM3. If the two CPM3’s are not able to communicate to each other then the synchronization of the new entries will fail.
A text message shall be outputted to the printer when AHS synchronization starts, stops, or fails.
A text message shall be outputted to the printer when AHS flash write starts, stops, or fails.
Option 0F: B32 Headers
Default (00)
Compatible with MAS B32 Automation Software through TCP/IP. To enable, change to [01].
B32 Headers apply only to TCP/IP automation messages, not serial messages or printer messages.
When enabled, ALL outgoing and incoming automation messages will contain 4 extra bytes at the start of each packet.
These four bytes are:
00 00 LL LL
Where:
LL LL = the BCD value of the size of the entire packet.
i.e., If the original length was 1B HEX bytes to be sent, the packet would be:
00 00 00 31 <original packet>
And the ACK back to the receiver would:
00 00 00 05 06
NOTE: The ACK back to the CPM3 (Ex."30 30-30 35 06" ASCII) will be at the end of the packet.
NOTE: For changes to this program option a reset of the unit is required before the new parameters are used.
Numeric Setting
Display
Description
0
None
no parity (default)
1
Odd
odd parity
2
Even
even parity
Содержание SG-System III
Страница 22: ...Line Card In This Chapter Standby Mode on page 19 Line Fault on page 21...
Страница 92: ...In this Chapter Options 00 47 on page 90 SG DRL3 IP Programming...
Страница 100: ...Printer Words...
Страница 105: ...Telco Connector Pin Outs...
Страница 107: ...DEC HEX BIN Conversion Chart...
Страница 109: ...ASCII Character Chart...
Страница 111: ...SG DRL3 SG DRL3E SG DRL3 2L Communication Formats...
Страница 113: ...Ports...
Страница 115: ...Events Messages...
Страница 124: ...Glossary...