CHAPTER FIVE - ADVANCED PROGRAMMING
59
SG-System I Operating Manual
5
SG-DRL3 Option 2F: Online Time Out
SG-DRL3-2L Option 12F/22F: Online Time Out
Default (1E)
The Online Time Out option hangs up after a predetermined time delay. Time Out range can be programmed from 01 to 255 seconds (Hex 01
- FF) or until the call is completed by the panel (Hex 00). When time out occurs, the line card hangs up and generates a signal to the printer
and to the automation (SIA identifier YS).
For Example:
Printer Message: "DRL Online Time-Out"
Automation: NYS0102 (shelf 01, slot 02).
00 = Disabled.
xx = Maximum number of seconds (Hex) before the receiver will automatically force termination of a call.
NOTE: Depending on the order of handshakes used, the default online timeout of 30 seconds may not allow
sufficient time for all handshakes to be sent before timeout occurs. This time may need to be extended to use
these handshakes.
For UL Listed products, the permitted setting is 1E (30s).
SG-DRL3/SG-DRl3-2L Dynamic Options: 30/130/230 - 3F/13F/23F
SG-DRL3 Options 30 - 3F: 3/1 - 4/1 Digit 0-F
SG-DRL3-2L Options 130/230 - 13F/23F: 3/1 - 4/1 Digit 0-F
The line card uses a unique Sur-Gard communication format to transmit data through the System to the central station computer. Event codes
corresponding to alarm codes in 10 to 40 Baud formats and DTMF 4/1 to 4/3 formats are used in this unique format to enable the computer
software to determine alarm types.
The receiver will use the last digit of data received in 3/1 and 4/1 formats to determine the computer event code. The event code will then be
transmitted to the central station computer. Refer to the Decoding Library for the complete set of event codes used by the line card. In Sec-
tions 30 through 3F, program ASCII codes according to the Decoding Library.
Do NOT use values other than 20-7F (ASCII).
02
Oscar
Greenland Eastern Standard Time (VTZ) GMT - 2
03
Papa
Eastern Brazilian Standard Time (BST)
GMT - 3
04
Quebec
Atlantic Standard Time (AST)
GMT - 4
05
Romeo
Eastern Standard Time (EST)
GMT - 5
06
Sierra
Central Standard Time (CST)
GMT - 6
07
Tango
Mountain Standard Time (MST)
GMT - 7
08
Uniform
Pacific Standard Time (PST)
GMT - 8
09
Victor
Alaska Standard Time (AKST)
GMT - 9
10
Whiskey
Hawaii Standard Time (HST)
GMT - 10
11
X-Ray
Nome Time (NT)
GMT - 11
Содержание SG-System III
Страница 22: ...Line Card In This Chapter Standby Mode on page 19 Line Fault on page 21...
Страница 92: ...In this Chapter Options 00 47 on page 90 SG DRL3 IP Programming...
Страница 100: ...Printer Words...
Страница 105: ...Telco Connector Pin Outs...
Страница 107: ...DEC HEX BIN Conversion Chart...
Страница 109: ...ASCII Character Chart...
Страница 111: ...SG DRL3 SG DRL3E SG DRL3 2L Communication Formats...
Страница 113: ...Ports...
Страница 115: ...Events Messages...
Страница 124: ...Glossary...